background image

Technical and Safety Notices

Please read the following important technical, safety 
and environmental notices before installing and using 
your amplifier.

Technical Notices

All reasonable design and engineering steps have been taken 
to ensure that these amplifiers always perform satisfactorily in 
their intended application and environment and will provide 
appropriate levels of support to ensure that all reasonable 
customer needs and expectations are met. Such support however 
is contingent on the following provisions.

1. 

These amplifiers are Class-I products and should be installed 

with a mains cable including the required earth connection to 
comply with the Safety Class-I.

2.

 These amplifiers should always be installed by competent 

and qualified personnel. Amplifier damage or failure caused by 
installation or operational errors may invalidate support, warranty 
or guarantees of performance.

3.

 These amplifiers are not suitable for use in locations where they 

may be accessible to minors.

4.

 These amplifiers are intended to be used specifically for the 

amplification of audio signals and for connection to moving-coil 
loudspeaker systems. Use of these amplifiers for amplification 
of signals outside the audio band (20Hz to 20kHz) or to drive 
transducers other than moving-coil loudspeakers may invalidate 
support, warranty or guarantees of performance.

5.

 These amplifiers should only be used within professionally 

installed and configured audio systems comprising input and 
output ancillary equipments that is known to be of an appropriate 
level of performance and in good operating condition. Any 
damage to, or unsatisfactory performance from, these amplifiers 
caused by inadequate or failed input or output ancillaries may 
invalidate support, warranty or guarantees of performance.

6.

 These amplifiers are intended to be installed and operated 

indoor in a controlled environment (pollution degree, PD2) 
within an ambient temperature range of 0°C to 40°C. These 
amplifiers are not intended for use above 2000 meters above sea 
level. Amplifiers installed or operated in environments outside 
these limits may invalidate support, warranty or guarantees of 
performance.

7.

 Specific warranty terms are the responsibility of the amplifier 

re-seller.

Safety and Environmental Notices

Note: The intent of the lightning flash with arrowhead symbol in a 
triangle is to alert the user to the presence of uninsulated “dangerous” 
voltage within the product’s enclosure that may be of sufficient 
magnitude to constitute a risk of electric shock to humans.

Note: The intent of the exclamation point within an equilateral 
triangle is to alert the user to the presence of important safety, and 
operating and maintenance instructions in this manual.

WARNING! TO PREVENT FIRE OR ELECTRIC SHOCK, DO 
NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

Ambient Temperature Note: If this equipment is 
operated in a confined or multiple rack installation, the 
internal ambient operating temperature may exceed 
the external ambient temperature. It is important 

to ensure in these circumstances that 
the published maximum operating 
temperature for the equipment is not 
exceeded.

Reduced Air Flow: Ensure that rack or 
other closed installation does not restrict 
the cooling airflow required for safe and 
reliable operation of the equipment.

Содержание UXA4403

Страница 1: ...UXA4403 User Manual...

Страница 2: ...vel of performance and in good operating condition Any damage to or unsatisfactory performance from these amplifiers caused by inadequate or failed input or output ancillaries may invalidate support w...

Страница 3: ...particularly at plugs convenience receptacles and the point where they exit from the apparatus 14 Do not unplug the unit by pulling on the cord use the plug 15 Only use attachments accessories specifi...

Страница 4: ...figuration 6 Connections 7 Operation 8 Specifications 2 Amplifier Overview UXA4403 amplifiers are a full rack width 2U format power amplifiers that can drive both conventional low impedance Lo Z 4 to...

Страница 5: ...configuration menus are accessed via the Control Web App interface and cover Input Zone Output and General Settings functions The Control web app configuration menus are described in Section 5 of this...

Страница 6: ...are primarily intended for standard 19 inch equipment rack installation If not to be installed in an equipment rack UXA4403 amplifiers can be placed free standing on a flat surface Adhesive rubber fe...

Страница 7: ...LAN IP address is 192 168 64 100 Configure the laptop or desktop computer for a fixed IP address in the same IP range eg 192 168 64 10 with Subnet mask of 255 255 255 0 or prefix 24 and set the Gatewa...

Страница 8: ...wn Note When adjusting input gain the input level display should remain green If it displays red the input gain should be reduced 5 3 Configuration Menus Opening a web browser that is network connecte...

Страница 9: ...signed to zones The GPIO Volume Control Diagram 4d option enables external volume control to be applied to individual zones The GPIO configuration menu can be found under the Settings Tab The Compress...

Страница 10: ...403 amplifier model and the input zone and output mode configuration The Routing menu Diagram 4f enables zones to be assigned to amplifier outputs Note Routing for zones specified as stereo will autom...

Страница 11: ...ion and management is described in Section 5 3 5 2 Select the appropriate zcp format speaker preset data file to import from either a Library or a computer folder The preset data will be applied to th...

Страница 12: ...well as adjusting global gain Diagram 4l Diagram 4l Preset Crossover Gain The Speaker EQ in the preset menu allows for configuring customized parametric EQ on the output level Diagram 4m Diagram 4m Pr...

Страница 13: ...audible increase the frequency setting one step at a time until the distortion is no longer audible Driver Alignment in the preset menu will allow for delay to be set between driver passbands Diagram...

Страница 14: ...nder the Device menu The Backup Restore menu enables amplifier configuration data to be downloaded to an external archive and enables previously saved configuration files to be uploaded and adopted by...

Страница 15: ...m Gain Trim Gain Trim Input Sensitivity Input Gain Input Gain Input Selection Input Setup Zone Setup Routing Output Setup Output 1 Output 2 Output 3 Output 4 Zone Adjustment Parameters Speaker Preset...

Страница 16: ...he zone to be configured The number of zones available and their channel format stereo or mono will depend on the amplifier model input setup and output mode Lo Z or Hi Z For example a two output ampl...

Страница 17: ...n 8 has a low output impedance and is able to supply a maximum current of 10mA Note GPIO Pin 1 and Pin 3 both offer ground connections Pin 1 is connected directly to the amplifier chassis Pin 3 is con...

Страница 18: ...Note Two output amplifier model connection sockets differ only in the deletion of channel 3 and channel 4 output connectors Digital Inputs UXA4403 amplifier S PDIF stereo digital audio input connectio...

Страница 19: ...ifiers to a TCP IP network is described in Section 5 of this manual Cable Gauge Table Lo Z installations 0 5dB attenuation 4 8 loads Cable Gauge Table 70V Hi Z installations 1 0dB attenuation 20 speak...

Страница 20: ...5 mm Connections Diagram 5b Balanced analog input cable connections Diagram 5c Output cable connections Low Z Mode Hi Z BTL Modes 5 mm 5 mm...

Страница 21: ...s is in addition to the CLASS 2 WIRING text intended to alert users to the risk of hazardous voltages Output connectors that could pose a risk are marked with the exclamation point Do not touch the ou...

Страница 22: ...Output Off No output signal present Green Signal present on one or more outputs Amber Signal limiting clipping on one or more outputs Red One or more channel pair is in overload protection mode Networ...

Страница 23: ...vel of performance and in good operating condition Any damage to or unsatisfactory performance from these amplifiers caused by inadequate or failed input or output ancillaries may invalidate support w...

Страница 24: ...2023 Eastern Acoustic Works All rights reserved Products are not drawn to scale All terms conditions and specifications subject to change without notice Eastern Acoustic Works One Main Street Whitinsv...