CAUTION:
To maintain all compliance ratings, keep AC input voltage between 100 V to 120 V
or 220 V to 240 V.
Replacement 115 V AC mains cord part number: 0021435
Replacement 230 V AC mains cord part number: 0015224
6 . 6
P OW E R C O R D R E C E P TA C L E
The Neutrik Powercon AC mains inlet on the rear panel accepts the detachable
power cords supplied with the unit.
120 V AC mains:
Use the 3-wire grounded ac cord with the NEMA 5-15 plug.
230 V AC mains:
Use the 3-wire grounded ac cord with the Schuko plug.
CAUTION:
It is the user’s responsibility to provide a proper AC mains
plug for any AC mains outlet configuration that differs from those supplied
with the product.
6 . 7
G R O U N D I N G
The chassis of this product is grounded through the grounding conductor of the power cord. To avoid
electric shock, plug the power cord into a properly wired and grounded receptacle before making any
connections to or operating the product.
DANGER:
This equipment must be operated with the power cord grounding conductor
connected to a properly grounded AC outlet. Do not disconnect, “lift,” or otherwise remove this
ground connection. Without this connection, accessible parts, including knobs and controls that
may appear to be insulated, can render an electric shock that can cause injury or death to
operating personnel.
Connect the supplied AC mains cord to the PowerCon jack on the rear of the loudspeaker. The
PowerCon system uses a locking connector. To lock, twist 1/4 turn clockwise after fully inserting it into
the receptacle. Then, connect the other end of the cable to the AC mains supply receptacle. This will
energize the loudspeaker.
6 . 8
A C L O O P C o n n e c t o r
The Neutrik Powercon AC mains and AC loop connectors are wired in parallel to
provide an AC mains inlet and outlet on each NTS250.
The blue AC mains inlet mates with a Neutrik Powercon NACFC3A (supplied). The
white AC mains outlet mates with a Neutrik Powercon NACFC3B (also supplied).
Therefore, to loop the AC mains from enclosure to enclosure, connect the AC mains
jumper cable as shown. Up to four (4) NTS250s can be looped in this fashion.
Use the AC loop connector to daisy-chain AC mains power from one enclosure
to another. The maximum, continuous load must not exceed 10 A for the 115 V
version and 5 A for the 230 V version..
NOTE:
The circuit breaker only protects the AC Loop outlet, not the AC
mains connector. If the continuous load connected to the AC Loop outlet
exceeds the rated load, the circuit breaker will trip. For this situation,
reduce the connected load and then manually reset the circuit breaker.
Page
9
AC MAINS
~220 - 240VAC
50 - 60Hz 350 W
Line 2
Line 1
Neutral
Line
(Un
g
rounded)
AC MAINS
~100 - 120VAC
50 - 60Hz 350W
1440W MAX
1440W MAX
Neutral or Grounded
Safety Ground
Black
White
Green
Brown
Blue
Green/Yellow Stripping
Conductors 115 V Models
Line or Ungrounded
Conductors 230 V Models
Line 2
Safety Ground
Line 1
NAC3FCA CONNECTIONS
AC MAINS WIRE COLOR CODE
Neutrik NAC3FCA
To ac Mains In
Neutrik NAC3FCB
From ac Mains Out
Recommended cable length for connecting
vertically adjacent enclosures =
300 mm to 450 mm / 12 in to 18 in