Setup and connection
5
4
Setup and connection
4.1 Requirements
Raw water requirements
The quality of the water at the inlet must fulfil the valid drinking water regulations applicable to the specific
country. In addition, the following threshold limits must be adhered to (
Installation site requirements
Frost free
Well ventilated, clean, dry
Firm, level surface for the water dispenser
No sources of heat next to the water dispenser
See Chapter
16 for space requirements and minimum clearance from the wall.
The water shut-off valve and the water dispenser must not be more than 3 m distance
from one another.
Stagnant water in long hoses can lead to contamination.
Minimum room size to prevent a hazardous concentration of carbon dioxide (please see table).
Carbonic acid bottle
Minimum room size (with approx. 10 % furniture)
Room height: min. 2.5 m
2 kg
15 m²
3 kg
22.5 m²
5 kg
37.5 m²
6 kg
45 m²
10 kg
75 m²
IMPORTANT
A gas alarm device must be installed if the room is less than the minimum room size.
Alternative: 2-fold air exchange within 24 hours (continuous exchange of air).
If the water dispenser and the carbonic acid bottle are located in different rooms, the
minimum room size shall apply to both rooms.
4.2 Water connection
Warning
Possible contamination
The water stop cock and the water dispenser must not be more than 3 m distance
from one another. Stagnant water in long hoses can lead to contamination.
Only use the supplied water hose for the water connection.
Caution
Possible leakage from improperly cut hoses
Use the hose cutter to ensure the hose cross section remains round and that the hose is
cut straight.
Required materials
Reduction 3/4” or 3/8”
Pressure reducer
Water clock
Water hose
Pressure gauge
Dummy plug
Locking clip
Hygiene spray
EAUVATION N° 2
Hose cutter