9
Instruction Manual
Effective March 2020
eaton
www.eaton.com
1.2 Features
YHPTZ41 series explosion-proof integrated camera set integrates
high-performance color camera, omni bearing variable speed PTZ,
multifunction decoder controller and infrared light source, and
also common communication protocols and speed. It will give you
clear and bright images even in low-light conditions, it plays an
important role in security system.
YHPTZ41can work at wide voltage range and its self-adaptation
function will satisfy most brands of the video camera. It has
power supply, signal and video triple protection against lighting,
safe and reliable.
YHPTZ41 is designed as a integrated unit, it can continuously
rotate 360° horizontally and rotate to ±90° vertically with no
external cable between the PTZ and the camera. A sun shade, rain
wiper and heating devices are equipped with the product.
1.3 Scope
This product is applicable for Zone 1 and Zone 2 hazardous areas
that explosive mixture of group IIA, IIB, IIC, T1~T4 gases, vapor
and air may exists, Zone 21 and Zone 22 hazardous areas that
explosive dust may exist and hazardous areas that both the
explosive dust and gas mentioned above exist.
1.4 Mechanical data
Material:
stainless steel 304 or 316L
Horizontal rotating range: CC
0~360°continues
Vertical rotating range:
- 90 ~ + 90°
Horizontal rotating speed:
0.1° ~ 40° /S Smooth variable
speed rotation
Vertical rotating speed:
0.1° ~ 40° /S Smooth variable
speed rotation
Preset position speed:
60° /S
Preset position number(s):
128
Preset position precision:
≤0.1 °
Lighting Protection:
Built-in lighting protection device
Automatic heating:
Starts below -10°C
Infrared light range:
Approximately 100 meters
Unit weight:
35kg (net weight)
Package weight:
38kg (gross weight)
Installation method:
Vertical
Front view
Side view
Figure 1.4.1.1 Dimensions
1.5 Electrical data
Input voltage:
Frequency:
100~240VAC
50~60Hz
Maximum current:
≤1A
Consumption:
≤100W
Electrical connection:
Cable of 3 meters
PTZ control & communication
method:
RS-485
PTZ control & communication speed: 2400, 4800, 9600, 19200bps
(default: 4800bps)
PTZ control & communication
protocol:
PELCO-P, PELCO-D, VICON
(default: PELCO-D)
Address code:
0~255(default: 1)
1.6 Service condition
Atmospheric pressure
80~110KPa
Ambient temperature
-40°C~+60°C
Relative humidity
≤95%RH(+25°C)
1.7 Electrical safeties (standard atmospheric pressure)
Insulation resistor: at voltage of DC500V, the resistor between the
power in terminals and the enclosure is no less than 100 MΩ;
Voltage withstand test: adopt voltage of 1500V, 50Hz at the power
in terminals and the enclosure for 1 minute, no break down or arc.