5 Installation
5.3 Interfaces
Touch display XV-102
10/2020 MN04802004Z-EN
Eaton.com
33
5.3.5
Ethernet
Tab. 11 Control LEDs of the Ethernet interface
Cable
Use screened twisted pair cable (STP) for networking:
For device to device connection (crossover cable)
For connecting to the hub/switch: 1:1 patch cable
Maximum cable length: 100 m.
Eaton recommends implementing measures for protecting against cyberattacks.
Fig.. 15 Ethernet interface (RJ45 socket)
LED
Signal
Meaning
ACT (yellow)
flashes
Ethernet is active (data traffic)
LINK (green)
lit
Active network is connected and detected
ACT
LINK
CAUTION
Forces on the Ethernet interface
Communications may be affected, and the connection's mechanical components
may be damaged, if the Ethernet interface is subjected to strong vibrations or the
RJ45 plug-in connection is subjected to pulling.
Protect the RJ45 plug-in connection from strong vibrations.
Protect the RJ45 plug-in connection from tensile forces at the socket.
Eaton cyber security
http://www.eaton.com/us/en-us/company/news-insight-s/cybersecurity.html
http://www.eaton.com/cybersecurity
Содержание XV100
Страница 1: ...Manual XV 102 Touch display 10 2020 MN04802004Z EN ...
Страница 6: ...Content 4 Touch display XV 102 10 2020 MN04802004Z EN Eaton com ...
Страница 22: ...3 Safety regulations 3 4 Device specific hazards 20 Touch display XV 102 10 2020 MN04802004Z EN Eaton com ...
Страница 24: ...4 Operating and indication elements 4 1 Overview 22 Touch display XV 102 10 2020 MN04802004Z EN Eaton com ...
Страница 60: ...6 Operation 6 4 Inserting and removing the SD card 58 Touch display XV 102 10 2020 MN04802004Z EN Eaton com ...
Страница 64: ...7 Maintenance and repairs 7 4 Troubleshooting 62 Touch display XV 102 10 2020 MN04802004Z EN Eaton com ...