background image

iv

 

XN300 switch XN-332-5ETH-UMS

InstructIon manual

   MN050011EN   August 2022   www.eaton.com

Safety information

The instructions in this manual are not intended as a 

substitute for proper training or adequate experience in the 

safe operation of the equipment described. Only competent 

technicians who are familiar with this equipment should 

install, operate, and service it.
A competent technician has these qualifications:

 

Is thoroughly familiar with these instructions

 

Is trained in industry-accepted high- and low-voltage safe 

operating practices and procedures

 

Is trained and authorized to energize, de-energize, clear, 

and ground power distribution equipment

 

Is trained in the care and use of protective equipment 

such as arc flash clothing, safety glasses, face shield, 

hard hat, rubber gloves, clampstick, hotstick, etc.

Following is important safety information. For safe 

installation and operation of this equipment, be sure  

to read and understand all cautions and warnings.

Hazard statement definitions

This manual may contain four types of hazard statements.

 

DANGER

INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH, IF 

NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.

 WARNING

INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF 

NOT AVOIDED, COULD RESULT IN DEATH OR SERIOUS INJURY.

 CAUTION

INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF 

NOT AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY.

NOTICE

INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF 

NOT AVOIDED, MAY RESULT IN EQUIPMENT DAMAGE ONLY.

Safety instructions

Following are general caution and warning statements that 

apply to this equipment. Additional statements, related to 

specific tasks and procedures, are located throughout the 

manual.

 

DANGER

HAZARDOUS VOLTAGE. CONTACT WITH HAZARDOUS VOLTAGE 

WILL CAUSE DEATH OR SEVERE PERSONAL INJURY. FOLLOW ALL 

LOCALLY APPROVED SAFETY PROCEDURES WHEN WORKING 

AROUND HIGH- AND LOW-VOLTAGE LINES AND EQUIPMENT.

 WARNING

BEFORE INSTALLING, OPERATING, MAINTAINING, OR TESTING 

THIS EQUIPMENT, CAREFULLY READ AND UNDERSTAND THE 

CONTENTS OF THIS MANUAL. IMPROPER OPERATION, HANDLING, 

OR MAINTENANCE CAN RESULT IN DEATH, SEVERE PERSONAL 

INJURY, AND EQUIPMENT DAMAGE.

 

 WARNING

THIS EQUIPMENT IS NOT INTENDED TO PROTECT HUMAN LIFE. 

FOLLOW ALL LOCALLY APPROVED PROCEDURES AND SAFETY 

PRACTICES WHEN INSTALLING OR OPERATING THIS EQUIPMENT. 

FAILURE TO COMPLY CAN RESULT IN DEATH, SEVERE PERSONAL 

INJURY, AND EQUIPMENT DAMAGE.

 

 WARNING

POWER DISTRIBUTION AND TRANSMISSION EQUIPMENT MUST 

BE PROPERLY SELECTED FOR THE INTENDED APPLICATION. IT 

MUST BE INSTALLED AND SERVICED BY COMPETENT PERSONNEL 

WHO HAVE BEEN TRAINED AND UNDERSTAND PROPER SAFETY 

PROCEDURES. THESE INSTRUCTIONS ARE WRITTEN FOR SUCH 

PERSONNEL AND ARE NOT A SUBSTITUTE FOR ADEQUATE 

TRAINING AND EXPERIENCE IN SAFETY PROCEDURES. FAILURE TO 

PROPERLY SELECT, INSTALL, OR MAINTAIN POWER DISTRIBUTION 

AND TRANSMISSION EQUIPMENT CAN RESULT IN DEATH, SEVERE 

PERSONAL INJURY, AND EQUIPMENT DAMAGE.

 

 WARNING

OVERLAPPING ZONES OF PROTECTION ARE REQUIRED. UPSTREAM 

PROTECTION DEVICE SETTINGS MUST PROVIDE ADEQUATE 

OVERCURRENT PROTECTION IN THE EVENT OF A SYSTEM OR 

PRODUCT FAILURE. FAILURE TO PROPERLY SELECT APPROPRIATE 

UPSTREAM COORDINATION PROTECTION CAN RESULT IN DEATH, 

SERIOUS INJURY, AND EQUIPMENT DAMAGE.

This manual contains important information regarding the 

operation and installation of the Active Voltage Conditioner. 

All operations on the Active Voltage Conditioner should be 

carried out by a trained technician familiar with the contents 

of this manual.

Содержание XN300

Страница 1: ...Instruction manual XN300 switch XN 332 5ETH UMS...

Страница 2: ...AR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT S...

Страница 3: ...and abbreviations vi Writing conventions vi XN300 SWITCH XN 332 5ETH UMS 1 Proper use 1 Overview of functions 1 Versions 1 Ethernet connections 2 LED status indicators 2 Potential relationship betwee...

Страница 4: ...ic tasks and procedures are located throughout the manual DANGER HAZARDOUS VOLTAGE CONTACT WITH HAZARDOUS VOLTAGE WILL CAUSE DEATH OR SEVERE PERSONAL INJURY FOLLOW ALL LOCALLY APPROVED SAFETY PROCEDUR...

Страница 5: ...or wire breakage on the signal side will not result in undefined states in the automation devices Ensure a reliable electrical isolation of the low voltage for the 24 V supply only use power supply un...

Страница 6: ...es The devices described here must only be set up and operated as specified in this manual and in the installation instructions provided with the device Installation commissioning operation maintenanc...

Страница 7: ...E G UNEXPECTED MOTOR STARTUPS AND EQUIPMENT BECOMING UNEXPECTEDLY ENERGIZED Overview of functions The XN 332 5ETH UMS XN300 switch features the same design as the other devices in the XN300 system The...

Страница 8: ...status indicators The device s status LEDs are located underneath the front cover and can be seen underneath the corresponding labels when they light up Table 1 LED meanings LED Color EtherCAT status...

Страница 9: ...must be installed in a horizontal position module designation on top In order to ensure that the maximum operating ambient temperature will not be exceeded make sure that there is enough clearance bet...

Страница 10: ...screwdriver to do this Figure 6 Locking the XN 332 5ETH UMS into place on the DIN rail Step 7 Check to make sure that the XN 332 5ETH UMS is solidly mounted Dismantling XN 332 5ETH UMS To remove the...

Страница 11: ...ctor simply needs to be slid into the appropriate contact In order to release the conductor simply press on the release mechanism e g with a screwdriver to pull out the conductor from the correspondin...

Страница 12: ...ecessary to make sure that a total current of 4 A is not exceeded per terminal External 24 Vdc voltages can also be distributed using an XN 322 4PS 20 power distribution module or XN 322 18PD P and XN...

Страница 13: ...462 XN 312 XN 322 E135462 NA certification cULus Protection type IEC IP20 Dimensions All XN300 system devices have the exact same dimensions Description Specification Dimensions W x H x D mm 25 x 101...

Страница 14: ...installed between the power supply and the end device Cable cross sections Cable cross sectional areas XN 332 0 39 inch 10 mm Solid mm2 0 2 1 5 0 39 inch 10 mm Flexible with uninsulated ferrule mm2 0...

Страница 15: ...9 Instruction manual MN050011EN August 2022 www eaton com...

Страница 16: ...rd Cleveland OH 44122 United States Eaton com 2022 Eaton All Rights Reserved Printed in USA Publication No MN050011EN Z26444 August 2022 Eaton is a registered trademark All trademarks are property of...

Отзывы: