Field
Contents
Additional Description
Plug
0
No cable is plugged.
1
Cable is plugged into charging station.
3
Cable is plugged into charging station and
locked.
This is the default idle state for all devices
with permanently attached cable.
5
Cable is plugged into charging station and
vehicle but not locked.
7
Cable is plugged into charging station and
vehicle, furthermore the cable is locked.
Charging is not possible until plug state “7” is
reached.
AuthON
0
Authorization function is deactivated.
1
Authorization function is activated.
Authreq
0
Authorization via RFID card is not required.
OR
The authorization via RFID card was already
performed.
1
Authorization via RFID card is required.
Enable sys
0
Charging state cannot be enabled.
1
Charging state can be enabled.
Enable user
0
Device is disabled (e.g. via “ena 0”).
1
Device is enabled.
Max curr
uint16
Possible values:
0; 6000 - 32000
Current value in mA offered to the vehicle via
control pilot signalization. (Signal type: PWM)
Max curr %
uint16
Possible values:
100 - 533; 1000
Duty cycle of the control pilot signal. The unit
displayed is not % but 0.1%, which means
that the value “1000” stands for a duty cycle
of 100%. For more information concerning
the control pilot refer to IEC 61851-1.
Curr HW
uint16
Possible values:
0; 6000 - 32000
Maximum current value in mA that can be
supported by the hardware of the device.
This value represents the minimum of the
DIP switch settings, cable coding and
temperature monitoring function.
Curr user
uint16
Possible values:
0; 6000 - 63000
Current setting in mA defined via UDP
current commands. (Default: 63000 mA)
Curr FS
uint16
Possible values:
0; 6000 - 63000
Current setting in mA defined via
fail-
safe
function.
Tmo FS
uint16
Possible values:
0; 10 - 600
Communication timeout in seconds before
triggering the Failsafe function.
Curr timer
uint16
Possible values:
0; 6000 - 63000
Current value in mA that will replace the
setting in the “Curr user” field as soon as