May  the  charging  cable  be  permanently  connected  to  the  EATON  xChargeIn 
(affects EATON xChargeIn with Type 2 socket)? 

EATON  recommends  unplugging  the  charging  cable  after  every  charging  procedure  and 
storing in a suitable location to prevent possible premature material fatigue. 

1.10  Can the charging procedure be controlled by external devices? 

Yes. The EATON xChargeIn has a connection for enabling charging by external devices (e.g. 
ripple  control  receivers  of  the  energy  supplier,  photovoltaic  systems,  time  switches,  home 
controllers  and similar). For example,  this allows charging to only occur if your photovoltaic 
system is producing enough power or when your energy supplier offers cheaper rates in the 
evening  and  no  other  consumers  in  your  household  require  the  available  power  more 
urgently. 

1.11  How can the EATON xChargeIn be cleaned? 

Cleaning the housing of the charging station, if necessary, using a moist cloth. Stubborn dirt 
can be removed using a mild, solvent-free, non-scouring cleaning agent. 

1.12  Can the housing of the EATON xChargeIn be painted or have labels and similar 

applied? 

The EATON xChargeIn consists of a removable design hood as well as the actual housing 
for the electronics. Only the design hood can have labels applied or be painted. 
 

 

Removable design hood 

Electronics housing 

Содержание xChargeIn

Страница 1: ...xChargeIn Frequently Asked Questions for users...

Страница 2: ...IN BE PAINTED OR HAVE LABELS AND SIMILAR APPLIED 5 2 POSSIBLE FAULTS 6 2 1 THE CHARGING PROCEDURE DOES NOT START 6 2 2 THE STATUS LED DOES NOT LIGHT UP FLASH 6 2 3 THE STATUS LED LIGHTS UP FLASHES RED...

Страница 3: ...NAL RFID CARDS TAGS PROGRAMMED 9 5 4 4 WHERE CAN I PURCHASE RFID CARDS TAGS 9 5 4 5 CAN RFID CARDS TAGS BE DELETED FROM THE EATON XCHARGEIN 9 5 4 6 CAN RFID CARDS TAGS BE READ OUT FROM THE EATON XCHAR...

Страница 4: ...y unplugging the charging cable at your vehicle The plug in the EATON xChargeIn is then automatically unlocked in the cable can be unplugged 1 5 Can the plug of the charging cable at the EATON xCharge...

Страница 5: ...e switches home controllers and similar For example this allows charging to only occur if your photovoltaic system is producing enough power or when your energy supplier offers cheaper rates in the ev...

Страница 6: ...es Solution The plug was unplugged during the charging procedure The plug was not locked correctly Unplug the plug and plug it in correctly observe that it locks correctly The plug was not plugged in...

Страница 7: ...r photovoltaic system etc Check whether any control devices are preventing charging at specific times 2 7 Authorization at the EATON xChargeIn expires upon plugging in the cord at the vehicle Die Erfa...

Страница 8: ...ensure a secure and permanent anchoring we recommend using a cement foundation Mounting the column on asphalt is not allowed For details on setting up the base please refer to the instructions for the...

Страница 9: ...tags according to ISO14443 can be used 5 4 3 How are additional RFID cards tags programmed The EATON xChargeIn is supplied with one RFID card from the factory with the RFID order option The first RFID...

Страница 10: ...device see installation manual 5 5 PLC modem order option 5 5 1 What is a PLC modem Power Line Communication used for in the EATON xChargeIn Power Line Communication PLC is used for communicating with...