Xenon beacon Xb15

   

TM332 Issue A

   

October

 2018   www.eaton.com

Xenon beacon XB15

English

Removing/replacing xenon tube

Unscrew the grub screw (2.0mm A/F hexagon key) in the 

flange of the cover 3 full turns (Do not fully unscrew). 

Unscrew and remove the cover and lens assembly using 

the spanner supplied to gain access to the inside of 

the unit.
Remove the old tube by unscrewing the terminal block 

fixings. The replacement tube can now be fitted (see 

xenon tube installation sheet, which is supplied with the 

replacement tubes).
Once the new tube has been correctly fitted, replace the 

cover assembly, ensuring the cover is fully screwed down. 

There should be a maximum gap of 0.2mm between 

the faces of the cover and enclosure to ensure o-ring 

compression. Ensure the cover seal is correctly seated in 

its groove during re-assembly. Re-tighten the grub screw 

(2.0mm A/F hexagon key) in the cover flange to secure 

the cover.

6.0 Special conditions for safe use

1.

Painting and other surface finishes, other than those

applied by the manufacturer, are not permitted.

2. In order to maintain the dust tight integrity of the

enclosures (IP6X), the threads of cable entry devices

and stopping plugs shall be sealed in accordance

with the applicable code of practice for flameproof

installation.

7.0 Certification/approvals

IECEx units

Certified to IEC60079-0, IEC60079-1 & IEC60079-31
Ex d unit (IEC certification No. IECEx BAS 05.0048X) 
Ex db IIC T

G

 Gb

Ex tb IIIC T

D

 Db IP66/67

T

amb.

Tube Energy

T-rating (T

G

)

T-rating (T

D

)

T

amb.

15J

T4

T135°C

(-55°C to +70°C)

T5

T100°C

(-55°C to +40°C)

10J

T4

T135°C

(-55°C to +70°C)

T5

T100°C

(-55°C to +55°C)

T6

T85°C

(-55°C to +40°C)

5J

T5

T100°C

(-55°C to +70°C)

T6

T85°C

(-55°C to +55°C)

The IECEx certificate and product label carry the IECEx 

equipment protection level marking 
Gb

Db
Where Gb signifies suitability for use in a Zone 1 surface 

industries area in the presence of gas. 
Where Db signifies suitability for use in a Zone 21 surface 

industries area in the presence of dust.

ATEX units

Certified to EN60079-0, EN60079-1 & EN60079-31
Ex d unit (ATEX certification No. Baseefa04ATEX0009X)
Ex db IIC T

G

 Gb

Ex tb IIIC T

D

 Db IP66/67

T

amb.

Tube Energy

T-rating (T

G

)

T-rating (T

D

)

T

amb.

15J

T4

T135°C

(-55°C to +70°C)

T5

T100°C

(-55°C to +40°C)

10J

T4

T135°C

(-55°C to +70°C)

T5

T100°C

(-55°C to +55°C)

T6

T85°C

(-55°C to +40°C)

5J

T5

T100°C

(-55°C to +70°C)

T6

T85°C

(-55°C to +55°C)

The ATEX certificate and product label carry the ATEX 

group and category marking:

II 2 GD

Where:

Signifies compliance with ATEX

II 

Signifies suitability for use in surface industries

Signifies suitability for use in a zone 1 area

 Signifies suitability for use in the presence of gases 

 Signifies suitability for use in the presence of dust

EN54-23:2010 visual alarm device – beacon 

XB15 (24Vdc units only)

Rating 21.6v- 26.4v DC Absolute. Amps 0.99 
Environment Type B Outdoor applications
IP code (IP33C) to BS EN 60529:1992
The Red lens Beacon is supplied with the following 

LPCB markings.

The White lens Beacon is supplied with the following 

LPCB markings.

This signifies unit compliance to the relevant European 

directives, in this case 89/106/EEC, along with the name 

and number of the notified body issuing the certificate 

of conformity.

Содержание XB15

Страница 1: ...Technical manual Xenon beacon XB15...

Страница 2: ...LAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT...

Страница 3: ...ing replacing xenon tube 4 6 0 SPECIAL CONDITIONS FOR SAFE USE 4 7 0 CERTIFICATION APPROVALS 4 IECEx units 4 ATEX units 4 EN54 23 2010 visual alarm device beacon XB15 24Vdc units only 4 These units al...

Страница 4: ...iv Xenon beacon Xb15 TM332 Issue A October 2018 www eaton com...

Страница 5: ...hould be in accordance with specification applying to the required application MEDC recommends that all cables and cores should be correctly identified Please refer to the wiring diagram in this manua...

Страница 6: ...ting pillars to gain access to the terminals Once termination is complete replace the PCB assembly onto the mounting pillars and fully tighten the thumbscrews taking care not to overtighten them Repla...

Страница 7: ...little or no maintenance GRP will resist attack by most acids alkalis and chemicals and is as resistant to concentrated acids and alkalis as most metal products However if abnormal or unusual environm...

Страница 8: ...ting TD Tamb 15J T4 T135 C 55 C to 70 C T5 T100 C 55 C to 40 C 10J T4 T135 C 55 C to 70 C T5 T100 C 55 C to 55 C T6 T85 C 55 C to 40 C 5J T5 T100 C 55 C to 70 C T6 T85 C 55 C to 55 C The IECEx certifi...

Страница 9: ...The maximum height of the device on the wall in metres with a minimum value of 2 4 m y The width in metres of the square volume covered to a minimum level of 0 4 lux when the device is mounted at a he...

Страница 10: ...7 4 2 and 2 7 4 4 XB15 Xenon Beacon Single Mode 1oo1 XB15 Xenon Beacon Redundant Mode 1oo2 Verdict Architectural constraints Safe Failure Fraction SFF HFT 0 HFT 1 Type B 62 62 SIL 1 Random hardware f...

Страница 11: ...h 1 DD DU 6 45E 09 3 48E 07 6 45E 10 3 48E 08 Random hardware failures h 1 SD SU 0 00E 00 8 84E 07 0 00E 00 8 84E 08 Diagnostic coverage DC 0 00 0 00 PFD PTI 8760Hrs MTTR 8 Hrs 1 53E 03 1 53E 04 SIL 2...

Страница 12: ...rongly recommended to test the product at least once a year 3 Selection of this equipment for use in safety functions and the installation configuration overall validation maintenance and repair shall...

Страница 13: ...ICA O APROVA ES 13 Unidades IECEx 13 Unidades ATEX 13 EN54 23 2010 dispositivo de alarme visual sinalizador luminoso de xen nio XB15 apenas para unidades de 24Vcc 13 Essas unidades tamb m disp em das...

Страница 14: ...conformidade com as especifica es referentes aplica o em quest o A MEDC recomenda que todos os cabos e condutores sejam identificados corretamente Consulte o esquema el trico reproduzido neste manual...

Страница 15: ...coloque o conjunto da PCI em seus pilares de montagem e aperte firmemente os parafusos tendo o cuidado de n o aplicar aperto excessivo Substitua o conjunto da tampa assegurando se de que esta tenha si...

Страница 16: ...GRP resiste ao ataque da maioria dos cidos bases e produtos qu micos em geral sendo resistente a cidos e bases concentrados como a maior parte dos produtos met licos Todavia recomenda se uma inspe o v...

Страница 17: ...T100 C 55 C a 40 C 10 J T4 T135 C 55 C a 70 C T5 T100 C 55 C a 55 C T6 T85 C 55 C a 40 C 5 J T5 T100 C 55 C a 70 C T6 T85 C 55 C a 55 C O certificado IECEx e a etiqueta do produto cont m a marca o do...

Страница 18: ...montado em paredes x A altura m xima do dispositivo na parede em metros com um valor m nimo de 2 4 m y A largura em metros do volume quadrado coberto a um n vel m nimo de 0 4 lux quando o dispositivo...

Страница 19: ...C61508 2 usando um intervalo de teste de prova de 730 horas Os resultados s o mostrados abaixo e s o baseados na Rota 1H O sinalizador luminoso classificado como um dispositivo do Tipo B Fun o de segu...

Страница 20: ...2 e 2 7 4 4 Sinalizador luminoso de xen nio XB15 Modo simples 1oo1 Sinalizador luminoso de xen nio XB15 Modo redundante 1oo2 Veredicto Limita es arquitet nicas Fra o de Falha de Seguran a SFF HFT 0 H...

Страница 21: ...utras aplica es recomenda se fortemente testar o produto pelo menos uma vez ao ano 3 A sele o deste equipamento para uso em fun es de seguran a e a instala o configura o valida o geral manuten o e rep...

Страница 22: ...ion contained in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Photos and pictures also do not warrant a...

Отзывы: