background image

8

Technical Data 

PR211-183-505-01

VoCALL CFVCCM9 compact master 

  

  

EATON

 www.eaton.com

Set time+date

Scroll through the root menu using the navigation keys until  

Set time+date is selected. Press TICK to show the Set  

time+date menu.

Set time + date
Date > 01|01|11
Time 14:15:06
 :Next

This menu shows the current date and time in the  

following format:
Day | Month | Year
Hour:Minute:Second
The cursor will be on the first option: Day. Use the navigation keys 

to select the correct day then press TICK to move to the Month 

option. Repeat until the current date and time are set and the next 

option is selected.
Most configuration menus will have the same options located 

in the bottom right of the LCD screen: Next, Save, and Quit. 

Pressing the TICK button selects the option chosen:

Next:

 

Moves cursor back to first option on screen.

Save:  

Stores information and moves back to the previous  

menu screen.

Quit:

 

 Discards all information on screen, and moves back 

to the previous menu screen.

 

 Use the navigation keys to select Next, Save, or 

Quit as desired, then press TICK. Both Save and 

Quit will go back to the root menu.

Change manager PIN

The default PIN to access the configuration menus is 3333, but 

this can be changed.
Scroll through the root menu using the navigation keys until 

Change manager Pin is selected. Press TICK to show the Change 

manager PIN menu.
There are 2 lines: New PIN and Repeat PIN. The cursor will be on 

the first digit of the New PIN. Use the navigation keys to change 

the digit, and press TICK to move to the next digit. Repeat until 

all digits have been entered for both the New PIN and the Repeat 

PIN, and the Next option is selected.

Change PIN
New PIN 0***
Repeat PIN ****
 :Next

New PIN:

 

 PIN number that will be used to access the  

configuration menus.

Repeat PIN:

   New PIN repeated. If this differs from the new PIN, 

then the new PIN number will not be ticked, and a 

warning message will be displayed on screen.

 Use the navigation keys to select Next, Save, or Quit as  

desired, then press TICK. Both Save and Quit will go back to  

the root menu.

Change engineer PIN

The default Engineer PIN to access the configuration menus is 

0000, but this can be changed.
Scroll through the root menu using the navigation keys until 

Change engineer PIN is selected. Press TICK to show the Change 

engineer PIN menu.
There are 2 lines: New PIN and Repeat PIN. The cursor will be on 

the first digit of the New PIN. Use the navigation keys to change 

the digit, and press TICK to move to the next digit. Repeat until 

all digits have been entered for both the New PIN and the Repeat 

PIN, and the Next option is selected.

Change PIN
New PIN 0***
Repeat PIN ****
 :Next

New PIN:

 

 PIN number that will be used to access the configu-

ration menus.

Repeat PIN:

   New PIN repeated. If this differs from the new PIN, 

then the new PIN number will not be ticked, and a 

warning message will be displayed on screen.

Use the navigation keys to select Next, Save, or Quit as  

desired, then press TICK. Both Save and Quit will go back to  

the root menu.

Log settings

The CFVCCM9 has three independent Logs: Faults, Events  

and Calls. For each of these logs there is a menu to allow  

you to set the visibility to non-logged in users, or to clear the log 

(engineer only).
Scroll through the root menu using the navigation keys until Log 

settings is selected. Press TICK to show the Log Settings Menu.

Log settings
Back
>Fault log settings
Event log settings
Call log settings

For each log, the following options are available.

Fault Log settings
Show Log >No
Clear log: No
 :Next

The cursor will be on the first option, Show log. Use navigation 

keys to select either yes or no then press TICK to move to the 

Clear log option. Pressing TICK again moves cursor to Next option.
Unlike other menus, the next option toggles between Next, Exec, 

and Quit. Use the navigation keys to select the desired option, and 

then press TICK.

Next:

 

Moves cursor back to show log option.

Exec:

 

 Executes command to clear log if clear log option is 

set to yes, and moves back to root menu.

Quit:

 

Moves back to root menu.

Содержание VoCALL CFVCCM9 compact master

Страница 1: ...ce Communications System EVCS is designed to fully comply with BS5839 Part 9 2011 abb Pt9 for use as a fire telephone system disabled refuge call system or as a combined system when both fire telephon...

Страница 2: ...und a site it is essential all units are on the same mains phase as they are classified TEN 230V powering from different phases can mean a 440V potential can be present in a unit during a major fault...

Страница 3: ...incoming mains Mains SHOULD NOT enter the box by any other hole If additional holes are required then the can be drilled as shown below taking care not to obscure the battery or PCB locations Unused...

Страница 4: ...pact unit and outstations Following the publication of BS5839pt9 2011 the guidance on cables for the VoCALL Compact unit has changed following a relaxation in the requirements of the standard Type A o...

Страница 5: ...ne Connector on Network Compact unit toYellow phone lead Hands free refuge point Type B Connections inside the Network Compact unit Line Connector on Network Compact unit toType B line Line Connector...

Страница 6: ...Set Site Name Menu The second line can be changed from Set Panel Name Menu The third line contains the status of the unit The fourth line shows the current time and date The padlock in the top right...

Страница 7: ...Missing outstation 4 Scroll through the root menu using the navigation keys until View current fault is selected Press TICK to enter the View current fault menu Use the navigation keys to scroll thro...

Страница 8: ...een Use the navigation keys to select Next Save or Quit as desired then press TICK Both Save and Quit will go back to the root menu Change engineer PIN The default Engineer PIN to access the configura...

Страница 9: ...n Set panel name Compact M9 Next The current master name will be displayed on screen with the cursor on the first character Use the navigation keys to scroll to the correct character then press TICK R...

Страница 10: ...th a symbol Select outstation S10 outstation 10 Back M9 Outstation 1 Unlocked this outstation exists Line through circle this outstation does not exist or is in fault Select the outstation to be confi...

Страница 11: ...uttons connected using the TICK key or if already connected placed on hold using the TICK key a second time If the CFVCCM9 master handset wishes to ring an outstation they may do this by scrolling thr...

Страница 12: ...free relay N A Contact 30V dc 1A N A Controls Buttons 4 navigation keys N A Display 4 lines 20 characters N A Status LEDs 3 healthy call supply 1 supply Fault LEDs 3 line PSU general 1 general Outsta...

Страница 13: ...de la Longeraie 7 1110 Morges Switzerland Eaton eu 2018 Eaton All Rights Reserved Publication No PR211 183 505 01 CSSC 930 February 2018 Eaton is a registered trademark All other trademarks are proper...

Отзывы: