Eaton Vikers V200 Series Скачать руководство пользователя страница 5

5

Model  Code

V  2  1  0  -  8  W  -  1  F  C  -  C  8  -  12  -  L  -  *

2

2

4

5

6

7

8

9

13

1

Vane pump

1

3

12

3

Series

Body Type

1 – Standard Threaded
2 – Standard Flange
3 – Face Threaded
4 – Face Flange
5 – Tapped Foot Threaded

4

0 – None
4 – Foot
5 – Flange
7 – Power Take-off

Mounting

10

11

14

5

10

Capacity in GPM (@ 1200 RPM)

6

Wide Ring (V200 only)

7

1 – Straight with Square Key
3 – Threaded
6 – Straight Stub with Woodruff Key
7 – Six-tooth Spline

11 – Splined
24 – Tang Drive
34 – Woodruff Key Threaded (Special)
37 – InvoluteSpline (Special)

Shaft Type

8

Connection Flanges Supplied

9

Port Positions (see Figure 6)

C – 750  PSI
D – 1000 PSI
E – 1250 PSI
F – 1500 PSI
G – 1750 PSI
H – 2000 PSI

Relief Valve Setting (V200 only)

11

Controlled Flow Rate (GPM)
(V200 only)

12

Design

13

14

Optional Left Hand Rotation

Special Features

Table 2

Section II  Description

A. General

Pumps in this series are used to develop hydraulic fluid flow for
the operation of Mobile equipment. The positive displacement
pumping cartridges are the rotary vane type with shaft side
loads hydraulically balanced. The flow rate depends on the
pump size and the speed at which it is driven.

All units are designed so that the direction of rotation,
pumping capacity and port positions can be readily changed
to suit particular applications.

B. Assembly and Construction

The V200 series pump illustrated in the cutaway in Figure 1
is representative of all single pumps in this series. The unit
consists principally of a ported body and cover, a drive shaft
supported by two ball bearings, a pumping cartridge and a
pressure plate. Components of the pumping cartridge are an
elliptical cam ring, a slotted rotor splined to the drive shaft
and twelve vanes fitted to the rotor slots.

As the rotor is driven by the driveshaft, the vanes generate
fluid flow by carrying fluid around the elliptical ring contour
(see Section III). Fluid enters the cartridge through the inlet
port in the body and is discharged through the pressure plate
to the outlet port in the cover.

C. Flow Control and Relief Valve

V200 pumps are available with an integral flow control and
relief valve in the pump cover. This limits the final flow in the
system to a maximum prescribed rate and prevents
excessive pressure buildup. Fluid not required in the system
is recirculated to tank.

D. Application

Pump ratings in GPM as shown in the model coding are at
1200 RPM. For ratings at other speeds, methods of
installation and other application information, Vickers
application enginering personnel should be consulted.

Содержание Vikers V200 Series

Страница 1: ...M 2000 S Revised 11 01 85 Vane Pumps V100 V200 V300 V400 V500 and V2P Series Overhaul Manual Vickers Vane Pumps...

Страница 2: ...2 EEaton Hydraulics Incorporated 2000 All Rights Reserved...

Страница 3: ...Installation and Operating Instructions A Installation Drawings 7 B Drive Connections 7 C Shaft Rotation 8 D Piping and Tubing 8 E Hydraulic Fluid Recommendations 8 F Overload Protection 9 G Port Pos...

Страница 4: ...Service parts information and installation dimensions are not contained in this manual The parts catalogs and installation drawings listed in Table 1 are available from Vickers Model Codes There are...

Страница 5: ...tation pumping capacity and port positions can be readily changed to suit particular applications B Assembly and Construction The V200 series pump illustrated in the cutaway in Figure 1 is representat...

Страница 6: ...ads on the shaft are cancelled C Pressure Plate The pressure plate seals the pumping chamber as shown in Figure 3 A light spring holds the plate against the cartridge until pressure builds up in the s...

Страница 7: ...tank Pressure in spring chamber lower than system due to pressure drop across sensing orifice Poppet forced off seat as relief valve setting is reached Spring orifice Figure 4A Low Drive Speed All Pu...

Страница 8: ...n of system components with particular emphasis on hydraulic pumps Any fluid selected for use with pumps is acceptable for use with valves or motors Three important factors in selecting an oil are 1 V...

Страница 9: ...should be closely monitored to avoid exceeding a temperature of 130 F with any of these light weight or diluted oils Where special consideratins indicate a need to depart from the recommended oils or...

Страница 10: ...id is added to the system it should always be poured through a fine wire screen 200 mesh or finer It is important that the fluid be kept clean and free from any substance that may cause improper opera...

Страница 11: ...eling on the valve periphery can be polished with crocus cloth Do not remove excess material round off the edges of the lands or attempt to polish the bore Wash all parts and reassemble the pump Vane...

Страница 12: ...rotor for scoring and excessive wear Remove light score marks by lapping Replace any heavily scored or badly worn parts 3 Inspect the vanes for burrs wear and excessive play in the rotor slots Replace...

Страница 13: ...or Cover Screw Flange Gasket Bearing Seal Bearing Ring Pin Pressure Plate Spring O ring Lockwasher not used on all models Model Tighten To V100 25 3 ft lbs V2 V200 70 5 ft lbs V300 100 10 ft lbs V400...

Страница 14: ...Figure 9 Install the rotor on the shaft and insert the vanes in the rotor slots Be certain the radius edges of the vanes are toward the cam ring View from Cover End Right Hand Rotation Left Hand Rotat...