4

Section I – Operating Characteristics 

Type

Hydro-cushion pressure control valves

. . . . . . . . . . . . 

Operating Fluid

High quality lubricating oil

. . . . . . . . . . . . . . 

Recommend Viscosity

100-250 SSU @ 100

°

F.

. . . . . . . . . 

Operating Pressure 

Maximum 2000 PSI

. . . . . . . . . . . . . . . 

Port Connections

Flange, gasket or threaded

. . . . . . . . . . . 

Mounting Position

Optional

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Model

Port

Size

Capacity

GPM

Installation Drawing

RT/RCT-03-**-1*
RG/RCG-03-**-1*
RT/RCT-06-**-1*
RG/RCG-06-**-1*
RT/RCT-10-**-1*
RG/RCG-10-**-1*
RT/RCT-12-**-1*
RF/RCF-16-**-1*

Parts

Drawing

“RC” Series

“RC” Series

3/8 inch

3/4 inch

1 1/4 inch

1 1/2 inch

2 inch

8

20

50

65

125

I-3325-S
I-3329-S
I-3326-S
I-3330-S
I-3327-S
I-3331-S
I-3327-S
I-3328-S

I-132395
I-133101
I-132395
I-133101
I-13395
I-133101
I-132395
I-133671

I-132396
I-133103
I-132396
I-133103
I-13296
I-133103
I-132396
I-133672

Table 1.  2.

Special Application
P - Auxiliary external pilot 

pressure control

Omitted standard control

1

3

4

5

8

7

6

1

2

7

8

9

2

3

5

6

Valve Type 3.
Pressure control

Valve Design
C - with integral check valve 
(Reverse free flow)
Omitted - Without check valve 
(no reverse flow)

Installation
F - Flange connected
G - Gasket mounted
T - Threaded connections

Pressure Rating
A - 75-250 PSI (with pilot piston)
B - 125-500 PSI (with pilot piston)
D - 250-1000 PSI (with pilot piston)
F-

500-2000 PSI (with pilot piston)

Z - 25-125 PSI (without pilot piston)

Design Number

Port Connections 
Nominal Pipe Size
03 - 3/8” female pipe thread
06 - 3/4” female pipe thread
10 - 1 1/4” female pipe thread
12 - 1 1/2” female pipe thread
16 - 2” flange female pipe thread

Circuit Application
1 - “R” Series, relief valve

(internal drain directly operated)
“RC” Series, counter balance valve 
(internal drain directly operated)

2 - Sequence Valve

(external drain remotely operated)

3 - Sequence Valve

(external drain remotely operated)

4 - “R” series, unloading valve

(internal drain remotely operated)
“RC” series, counter-balance valve 
(internal drain remotely operated)

Table 1. Model Code Breakdown

4.

9

4

Special Feature
O - Normally open spool 
(decompression circuits)
Omitted - Normally closed spool
(standard)

9

Design Modification

For satisfactory service life of these components, use full flow filtration to provide fluid which meets ISO cleanliness code
20/18/15 or cleaner. Selections from pressure, return, and in-line filter series are recommended.

Содержание Vickers RCF Series

Страница 1: ...I 3332 S Revised 9 1 87 Pressure Control Valves Hydro Cushion Type RF RG and RT Series RCF RCG and RCT Series Vickers Pressure Relief Overhaul Manual...

Страница 2: ...2 EEaton Hydraulics Incorporated 2000 All Rights Reserved...

Страница 3: ...ble 1 Installation and Parts Drawings 4 Table 2 Model Code Breakdown 4 II Description 5 Figure 1 5 III Installation 6 Figure 2 6 IV Operation 7 V Special Features 8 Figure 3 8 VI Overhaul 9 A Disassem...

Страница 4: ...low Installation F Flange connected G Gasket mounted T Threaded connections Pressure Rating A 75 250 PSI with pilot piston B 125 500 PSI with pilot piston D 250 1000 PSI with pilot piston F 500 2000 P...

Страница 5: ...s are designated as Types 1 2 3 and 4 Each type is available with or without the integral check valve permitting reverse free flow TYPE 1 is internally drained and directly operated It is used as a re...

Страница 6: ...depending on the application and type of valve used The RG RCG series gasket mounted valves are teed into the supply line The tee connection is piped to the bottom or pressure port in the subplate or...

Страница 7: ...the pressure setting of the valve When the primary pressure decreases compression of the spring overcomes the hydraulic force effective on the piston and spool closes blocking flow to chamber B Fluid...

Страница 8: ...Valve installed between the Gage Ports Primary Port outlet to ram or control return flow Normally open Spool Type O Auxiliary Control Type P Control Pressure Port 2 Orifice of size required drilled in...

Страница 9: ...ng Table 3 For complete disassembly See Figure 4 remove the valve from the installation Dismantle in the same order as the key index numbers assigned to the exploded view B Reassembly 14 Reassemble in...

Страница 10: ...ain spool plugged 3 Main spool stuck in open position 4 Control piston binding in up position Readjust valve to proper setting Remove spool Blow out hole with fil tered compressed air Remove spool Che...

Страница 11: ...All rights reserved Printed in U S A Eaton Hydraulics 15151 Highway 5 Eden Prairie MN 55344 Telephone 612 937 7254 Fax 612 937 7130 www eatonhydraulics com 46 New Lane Havant Hampshire PO9 2NB Englan...