Eaton Corporation Page 64 Ver 1.1
10. Specifications
Model
PV238
PV240
PV250
PV260
PV270
Input (DC)
Nominal DC
Voltage
360V
Max. PV
Open Voltage
600V
Start-up Voltage
150V
Shutdown
Voltage
Typical 80V
Working Voltage
Range
100 ~ 515 V
Full Rating
Voltage Range
225 ~ 500V
200 ~ 500 V
MPPT Working
Range
105 ~ 500 V
105 ~ 500 V
MPPT Efficiency
> 99%
MPPT Tracker(s)
1
Max DC Current
19A
26A
32A
37A
Output (AC)
Nominal AC
Power @ 240Vac
/ 277Vac
3800W
4000W
5000W
6000W
7000W
Nominal AC
Power @ 208Vac
3800W
3800W
4600W
6000W
7000W
Max. AC Power @
240Vac / 277Vac
3800W
4000W
5000W
6000W
7000W
Max. AC Power @
208Vac
3800W
3800W
4600W
6000W
7000W
Nominal Voltage
Defaulted: 240 Split phase
Optional: 208V, 240V or 277V single phase (setting required)
Operational
Voltage Range
186V ~ 225V for 208Vac system
215V ~ 260V for 240Vac system
248V ~ 300V for 277Vac system
Nominal
Frequency
60Hz
Operational
Frequency Range
59.32Hz ~ 60.48Hz