0 About This Manual

0.3 Writing conventions

4

DB1 Variable Frequency Drives

09/17 MN040034EN

www.eaton.com

0.3 Writing conventions

Symbols with the following meaning are used in this manual:

Indicates instructions to be followed.

0.3.1 Hazard warnings of material damages

0.3.2 Hazard warnings of personal injury

0.3.3 Helpful hints

ATTENTION

Warns about the possibility of material damage.

WARNING

Warns of the possibility of hazardous situations that may 
possibly cause slight injury.

WARNING

Warns of the possibility of hazardous situations that could result 
in serious injury or even death.

DANGER

Warns of hazardous situations that result in serious injury or 
death.

Indicates useful tips.

All the specifications in this manual refer to the hardware and 
software versions documented in it.

More information on the devices described here can be found 
on the Internet under:

www.eaton.eu/powerxl

as well as:

www.eaton.eu/documentation

Содержание PowerXL DB1

Страница 1: ...Manual PowerXL DB1 Variable Frequency Drives Parameter Manual L1 L2 L N L3 U V W 09 17 MN040034EN...

Страница 2: ...m 8 00 a m EST Drives Technical Resource Center Voice 877 ETN CARE 386 2273 option 2 option 6 8 00 a m 5 00 p m Central Time U S UTC 6 email TRCDrives Eaton com www eaton com drives Original operating...

Страница 3: ...ation system may cause damage to persons or property external measures must be implemented to ensure a safe operating state in the event of a fault or malfunction for example by means of separate limi...

Страница 4: ...menu 10 2 6 Control via keypad 11 3 Control signal terminals 12 3 1 Correspondence between inputs outputs and terminals 12 3 2 Configuration of the control signal terminals 16 3 2 1 P 12 0 Terminal mo...

Страница 5: ...MN040034EN www eaton com 4 Messages 25 4 1 List of messages 25 4 2 Operating status indicators 27 5 Parameters 29 5 1 Monitor parameter group 29 5 2 Basic parameter group 32 5 3 Extended parameter gro...

Страница 6: ...cal engineering and physics related knowledge and skills will be required in order to be able to commission the corresponding devices We assume that you have a good knowledge of engineering fundamenta...

Страница 7: ...lity of material damage WARNING Warns of the possibility of hazardous situations that may possibly cause slight injury WARNING Warns of the possibility of hazardous situations that could result in ser...

Страница 8: ...ed only parameter group 1 Basic will be accessible Extended parameter set By entering a password in parameter P 14 Level 2 Extended can be accessed The default password is Access to level 2 101 Users...

Страница 9: ...Menu structure Monitor Advanced Advanced Monitor Basic Extended OK P00 P00 P0 P P P 31 01 00 01 15 60 32 02 02 16 61 49 29 13 58 67 50 30 14 59 68 Level 1 Password entry Level 2 extended password set...

Страница 10: ...rnal keypad DX KEY LED2 Figure 1 Operating unit view Table 2 Keypad elements Buttons Display Pushbuttons Button Command Explanation OK Opens and closes the parameter interface Saves parameter values S...

Страница 11: ...e parameter s value Press the OK button to confirm the parameter value change Press the OK button and hold it down for two seconds in order to exit the parameter interface Navigating between parameter...

Страница 12: ...the and buttons to enter the password set with P 37 default setting 101 Press the OK button to confirm The extended parameter set Parameter P 14 and display value P00 is now available Disabling acces...

Страница 13: ...select parameter P 00 Press the OK button The submenu with P00 01 to P00 30 is now accessible Note The parameter range from P00 01 to P00 50 is available in the menu for advanced users level 3 Naviga...

Страница 14: ...ction FWD P 12 2 two operating directions FWD REV START Starts the variable frequency drive Accelerate Decrease speed START Changes the operating direction if the motor is running Note P 12 2 only OK...

Страница 15: ...15 can be used to select the configuration for the control signal terminals More specifically you can select predefined terminal configurations by setting P 15 to a value between 0 and 8 The setting...

Страница 16: ...ve stops it will be locked In applications with two operating directions the reverse direction can be selected with REV FWD and REV are XOR d If both signals are applied simultaneously the drive will...

Страница 17: ...from the bus and fixed frequency 4 f Fix4 which is set with P 23 Low Setpoint value from bus High f Fix4 Select DIG REF AI1 REF Used to select between the digital speed setpoint value set with the key...

Страница 18: ...ituations until it is no longer able to work When this mode is selected drive fault signals will be ignored Low Fire mode High Normal mode Select PI REF AI1 REF Used to select between setpoint values...

Страница 19: ...D Select AI1 REF f Fix1 EXTFLT AI1 REF 4 FWD Select AI1 REF AI2 REF AI2 REF AI1 REF 5 FWD REV Select AI1 REF f Fix1 AI1 REF 6 START DIR EXTFLT AI1 REF 7 FWD REV EXTFLT AI1 REF 8 START DIR Select f Fix...

Страница 20: ...terminal 4 DI4 AI1 terminal 6 0 START UP DOWN DIR 1 Not permissible 2 FWD UP DOWN Select DIG REF f Fix1 3 FWD UP EXTFLT DOWN 4 START UP Select DIG REF AI1 REF AI1 REF 5 Not permissible 6 START DIR EX...

Страница 21: ...n will be stored when the unit is switched off P 15 DI1 terminal 2 DI2 terminal 3 DI3 AI2 terminal 4 DI4 AI1 terminal 6 0 START UP DOWN DIR 1 Not permissible 2 FWD UP DOWN Select DIG REF f Fix1 3 FWD...

Страница 22: ...n 1 Not permissible 2 Not permissible 3 START Select BUS REF f Fix1 EXTFLT No function 4 Not permissible 5 START Select BUS REF f Fix Select f Fix Bit0 No function 6 START Select BUS REF AI1 REF EXTFL...

Страница 23: ...ible 3 START Select BUS REF f Fix1 EXTFLT No function 4 Not permissible 5 START Select BUS REF f Fix Select f Fix Bit0 No function 6 START Select BUS REF AI1 REF EXTFLT AI1 REF 7 START Select BUS REF...

Страница 24: ...back AI1 REF 2 Not permissible 3 FWD Select PI REF f Fix1 EXTFLT PI feedback 4 Not permissible 5 Not permissible 6 Not permissible 7 Not permissible 8 Not permissible 9 Not permissible 10 Not permissi...

Страница 25: ...PI REF AI1 REF PI feedback AI1 REF 2 Not permissible 3 FWD Select PI REF f Fix1 EXTFLT PI feedback 4 Not permissible 5 Not permissible 6 Not permissible 7 Not permissible 8 Not permissible 9 Not permi...

Страница 26: ...Not permissible 2 Not permissible 3 START Select BUS REF f Fix1 EXTFLT No function 4 Not permissible 5 START Select BUS REF f Fix Select f Fix Bit0 No function 6 START Select BUS REF AI1 REF EXTFLT A...

Страница 27: ...e 3 START Select BUS REF f Fix1 EXTFLT No function 4 Not permissible 5 START Select BUS REF f Fix Select f Fix Bit0 No function 6 START Select BUS REF AI1 REF EXTFLT AI1 REF 7 START Select BUS REF DIG...

Страница 28: ...s are too short and require too much power If P 03 or P 04 cannot be increased a larger device may be required I t trP Motor overload The thermal protection mechanism has tripped as a result of the de...

Страница 29: ...tart the drive the temperature must be higher than this th f t Malfunctioning heat sink thermistor Please contact your nearest Eaton sales branch E trip External fault at digital input 3 terminal 4 Th...

Страница 30: ...n this case Standby to Off Flashing every 3 seconds The drive goes intostandby modeafterit has been operated for the time defined using P 48 with a minimum frequency of f min P 02 Failed to read line...

Страница 31: ...r set is incompatible with the device different performance class or different firmware version Upgradingsoftwarepower unit All colors flash intermittently in the following sequence green yellow red y...

Страница 32: ...he signal applied to analog input 2 after scaling and offsets have been applied P00 03 Frequency setpoint P 01 P 01 Frequency Reference in Hz Will be calculated into rpm when motor data are available...

Страница 33: ...urrent0 Log 0 A 2 Ie Motor current log Shows the last eight motor current values before the device was switched off due to a fault The sample interval is 256 ms P00 18 DC Link V Ripple0 Log 0 V 1000 V...

Страница 34: ...er Overtemperature Heatsink 0 65535 Indicates how often Overtemperature Heatsink occurred P00 37 FaultCounter Overcurrent Brake Chopper 0 65535 Indicates how often Overcurrent Brake Chopper occurred P...

Страница 35: ...time in seconds The time interval set in t dec represents the time taken to decelerate from Motor Nom Frequency P 09 to zero 5 0 s P 05 Stop mode 0 3 Determines the action taken by the drive in the ev...

Страница 36: ...09 is changed the following parameters will be reset to their default settings P 01 f max P 02 f min P 10 Motor Nom Speed P 20 f Fix1 P 21 f Fix2 P 22 f Fix3 P 23 f Fix4 50 hz P 10 Motor Nom Speed 0...

Страница 37: ...via Modbus RTU communication 4 Control via Modbus Ramp times via Modbus 5 PI controller with external actual value 6 PI controller with external actual value and totalized value of AI1 7 CANopen inte...

Страница 38: ...f fix1 P 20 in case of wire break 7 10 0V 0 P 17 Switching frequency 0 f Ie Power stage switching frequency Higher frequency reduces the audible ringing noise from the motor and improves the output c...

Страница 39: ...ignal If P 09 is changed the value is reset to default 0 0 Hz P 24 t QuickDec 0 00 s 600 0 s Quick Stop Ramp In default the second deceleration ramp is activated by applying voltage to DI1 and DI2 ter...

Страница 40: ...wing a trip due to a fault the drive will automatically make up to five attempts to restart at 25 second intervals The drive must be powered down to reset the counter The number of restart attempts ar...

Страница 41: ...1 Note The settings for P 33 will be adjusted if parameter P 13 is changed P 33 0 if P 13 0 or 1 P 33 2 if P 13 2 0 P 34 Brake Chopper 0 4 Enable Brake Chopper Enables the brake chopper for size FS2...

Страница 42: ...0 no action 1 t 30 ms 2 t 100 ms 3 t 1000 ms 4 t 3000 ms 5 r 30 ms 6 r 100 ms 7 r 1000 ms 8 r 3000 ms 4 P 37 Password Level2 0 9999 Defines the password which is used to get access to extended parame...

Страница 43: ...y 1 P 42 PID1 Control I Time 0 0 s 30 0 s PI D controller integral time constant Higher values will result in a more damped response Used in systems in which the overall process responds slowly 1 0 s...

Страница 44: ...soon as the speed set point increases above P 02 0 0 s P 49 PID1 WakeUpLevel 0 00 100 00 Wake up level controller 1 Sets an error level difference between the PID reference and feedback values above w...

Страница 45: ...logic 1 if value switching point output will be logic 0 if value switching threshold P 18 6 or 7 Output will be logic 0 if value switching point output will be logic 1 if value switching threshold 0...

Страница 46: ...and Ti as combined value 50 00 P 63 I CurrentLimit 0 10 175 Current limit in amperes x 10 one decimal place 150 P 64 Motor Stator Resistance R1 0 00 Ohm 655 35 Ohm Stator resistance of the motor For...

Отзывы: