120
Eaton Power Xpert 9395 UPS Installation and Operation Manual 164201716—Rev 13
Table 31. Display Menu Operation (Continued)
Function
Subfunction
Operation
arrow pushbutton to set the time. Press
SAVE
or
ABORT
. Once the action is
completed, the Energy Saver System Setup screen is displayed.
High Alert Timer
The High Alert Timer screen sets the length of time the UPS remains in Online
mode before transferring back to Energy Saver System mode. The time can be set
in 10 minute increments from 0 to 990 minutes. Select
HIGH ALERT TIMER
from
the Energy Saver System Setup screen to display the High Alert Timer screen. Use
the up or down arrow pushbutton to set the time. Press
SAVE
or
ABORT
. Once the
action is completed, the Energy Saver System Setup screen is displayed.
Variable Module
Management
System
The Module Management System Setup screen allows the Variable Module
Management System function to be configured. Select
MODULE MANAGEMENT
SYSTEM SETUP
from the System Setup Level 0 menu to display the Module
Management System Setup screen. Use the up or down arrow pushbutton to
highlight the desired function, then press the
SELECT
pushbutton. To return to the
System Setup screen, press the
ESC
pushbutton.
VMMS Load Limit
The VMMS Load Limit screen sets the maximum load that can be drawn from a
UPM before additional UPMs are activated. Select
APM LOAD LIMIT
from the
Module Management System Setup screen to display the VMMS Load Limit screen.
Use the up or down arrow pushbutton to set the load limit. Press
SAVE
or
ABORT
.
Once the action is completed, the Module Management System screen is
displayed.
VMMS UPM
Redundancy
The VMMS UPM Redundancy screen sets the number of UPMs to remain active to
maintain redundancy. Select
VMMS UPM REDUNDANCY
from the Module
Management System Setup screen to display the VMMS UPM Redundancy screen.
Use the up or down arrow pushbutton to set the number of UPMs. Press
SAVE
or
ABORT
. Once the action is completed, the Module Management System Setup
screen is displayed.
High Alert Timer
The High Alert Timer screen sets the length of time the all UPMs remain active
before transferring back to Variable Module Management System mode. The time
can be set in 10 minute increments from 0 to 990 minutes. Select
HIGH ALERT
TIMER
from the Module Management System Setup screen to display the High
Alert Timer screen. Use the up or down arrow pushbutton to set the time. Press
SAVE
or
ABORT
. Once the action is completed, the Module Management System
Setup screen is displayed.
System Level 1
Setup
Password
The System Setup Level 1 screen can be used to set the UPS date and time, set the
serial ports, change the Level 1 password, and log out of Level 1. In addition, the
Level 0 functions are available. A password is required to access the Level 1
functions. To enter the password, select
ENTER PASSWORD
from the System
Setup Level 0 menu to display the Enter Password screen. Use the left or right
arrow pushbutton to select the password character position. Use the up or down
arrow pushbutton to change the password character. Once the password is entered,
press the
DONE
pushbutton. The System Setup Level 1 menu screen is displayed.
The default password is L1.
Function Selection
Use the up or down arrow pushbutton to highlight the setup function screen
desired, then press the
SELECT
pushbutton to display the function screen. The
Level 1 screen times out after 60 minutes or can be logged out at any time by
selecting the
LOG OUT
function from the menu screen.
Содержание Power Xpert 9395 275
Страница 1: ...p n 164201716 Revision 13 225 550 kVA Installation and Operation Manual Power Xpert 9395 550 275 UPS...
Страница 8: ......
Страница 18: ...xviii Eaton Power Xpert 9395 UPS Installation and Operation Manual 164201716 Rev 13 List of Figures...
Страница 31: ...10 Eaton Power Xpert 9395 UPS Installation and Operation Manual 164201716 Rev 13 Introduction...