IO5—6 x DI 240 Vac input Option Card
PowerXL DG1 Series Option Cards
MN040007EN—April 2014 www.eaton.com
29
Table 23. IO5 Parameters
Note:
X is indicating that it could be in slot A or slot B, which would change the value shown.
Input functions are set in the drive application under the
digital input selections. Depending on which slot is used, the
function will be set up with DigIN: X: IO5: Y, X being the slot
the board is placed in and Y being the input that is being used
on that board.
Figure 25. Input Functions
Monitor Menu—BX.1
Code
Parameter
ID (Slot A / Slot B)
Description
R / RW
BX.1.1
AC Digital Input board
908 / 934
Input signal status
R
BX.1.2
AC Digital input 4–6
1696 / 1697
Input signal status
R