3. Safety Instructions

This product should be installed, inspected, and maintained by a qualified 
electrician only, in accordance with national regulation, including the relevant 
standard and, where applicable. The national safety rules and regulations for 
prevention of accidents and the following safety instructions in these operating 
instructions, will have to be observed!

Do not operate in ambient temperatures above those indicated on the 

luminaire nameplate.

The luminaires shall be operated as intended and only in undamaged and 

perfect conditions! And Keep tightly closed when in operation!

The technical data indicated on the luminaire are to be observed!

Change of the design and modifications to the luminaire are not permitted!

Multiple, short-term switching must be observed! 

Only genuine Cooper Crouse-Hinds spare parts may be used for replacement!

!

2. Technical data

Enclosure specification

Material of enclosure: Aluminum alloy without Cu

Finish: Painted polyester power coating

Material of globe: Tempered glass

Mounting bracket: Stainless steel or Steel painted

Fasteners: All external fasteners stainless steel

Installation:  Mounting bracket with aiming quadrant

Weight: 4.5Kg(Normal version)/6Kg(EM version)

Ambient temperature: -40ºC~+55ºC

Degree of protection: IP 66 acc. to EN60529/IEC60529

Entry specification

Indirect entry

: 2

×

M20

×

1.5 or 2

×

M25

×

1.5 cable entry. One entry 

is fitted with an stopping plug. 

Direct entry

: M25 or G3/4 cable entry. 

Electrical specification

Wattage: 28W/46W/51W/63W/75W

Voltage: AC: 100V-240V 50/60Hz, DC: 108~250V

Lamp: LED Arrays

CRI: 70

Insulation class: I acc. to IEC60598

Terminals capacity: 3 core or 6 core conductor/cable

Solid: 0.5~6mm

2

, Flexible: 0.25~4mm

2

5. Installation

5.1 General

The respective national regulations as well as the 
general rules of  engineering which apply to the 
installation and operation of apparatus will have to 
be observed!

The improper installation and operation may result 
in the invalidation of the guarantee.

5.2 Mounting luminaire

5.2.1 Mounting the bracket

Only use the accompanying mounting bracket! 
Securely fasten the mounting bracket to a suitable 
base with sufficient load-bearing capacity. The 
mounting should be secured with M8 bolts and 
relative lock washers, nuts should be used.

5.2.2 Adjustment of floodlight

The luminaire can be adjust and lock the luminaire to 
30-degree intervals. The holes in the bracket gives 
increments of 30 degree. Loosen the set screw and 
fixing bolts to rotate the bracket to set the required 
tilt angle. 

4. Fields of Application

The Luminaire with a separate terminal box and IP66 sealing making it suitable for 
use for The luminaire is designed for use areas in indoors and outdoors in Marine 
and Wet locations, where moisture, dirt, corrosion, vibration and rough usage may 
be present. Application ambient temperature is -40

ºC

~+55

ºC

.  The enclosure 

materials used, including any external metal parts, are High quality materials that 
ensure a corrosion resistance and resistance to chemical substances according to 
the requirements for use in a “normal“ industrial atmosphere. In case of use in an 
extremely aggressive atmospheres, please refer to manufacture.

Re-tighten the set screw and fixing screws. 

See Fig.1 for details

.

The minimum distance between the luminaire 
and illuminated surface, directly in front of the 
luminaire, is 0.5 meter. The lamp must not be 
illuminated when at a distance of less than 0.5m 
from inflammable material.

5.3 Cable entries/Blanking plugs

Unused holes must be closed with certified plug.
The cable glands and plugs should be certified
and sealing washer 

(if required by manual of 

cable gland/plug) must be used to obtain IP66. 

The authoritative mounting guidelines for the
cable glands used must be observed. Mounting 
the selected cable entries acc. type and 
dimensions of the main connection cable 
following their manufacturer instructions. The 
cable temperatures are given as the rise over the 
max. rated ambient (Tamb). This allows the user 
to adjust the cable specification for actual 
maximum site ambient. 

Only heat resistant cable according to the data on 
the type label may be used! The max. conductor 
size is 4mm². The standard looping cable size is 
4mm².

5.4 Opening/closing the luminaire

5.4.1 General

The opening of luminaire always shall be without 
voltage! All gasket seals must be clean and 
undamaged before closing the luminaire. Make 
sure the luminaires is well closed before operation!

5.4.2 Terminal chamber cover

Unscrew the screws and remove the terminal 
chamber cover. And carry out the steps in reverse 
order to close the luminaire. Check all screws to 
ensure a secure fit during operation (Torque for 
screws: 1.5 Nm).

5.5 Electrical connection

The electrical connection of the lamp must only be 
established by qualified electricians. 
Make sure the supply voltage is the same as the 
luminaire voltage! 

1. 

Dimensions

EM version/Indirect entry

Normal version/Indirect entry

Normal version/Direct entry

EM version/Direct entry