Eaton PanelMate 5000 Series Скачать руководство пользователя страница 3

Connections

Connect DC Power

Your PanelMate unit is designed to operate at
24VDC -15%/+20%. A removable three-position DC
power connector attaches to the unit's connector
receptacle. The DC input common (-terminal) and
the chassis GND terminal are both internally
connected to the PanelMate chassis.

Use #18 AWG (0.82mm ) copper wire for
power and ground lead connections.

Power conditioning may be required when

the PanelMate unit is installed in areas of
poor power quality.

Note:

Note:

2

Your PanelMate unit could be damaged if it is

connected to voltages outside the range of 18 to

30VDC. Your PanelMate unit is fully protected

against polarity reversal and will not operate if

input polarity is reversed.

Connection to a Personal Computer

Connection to the Fault Relay

Connection to the Audio Output

Connection to the Security Keyswitch

Executive firmware and PanelMate configurations
are uploaded/downloaded to a personal computer
using the PanelMate unit's serial port. A transfer
serial cable is provided with your PanelMate
Configuration software. Refer to your PanelMate
Getting Started Manual for more information.

The fault relay may be wired in normally open or
normally closed configuration. It is a Form C
contact, rated for 2 amps at 120VAC, 2 amps at
230VAC, and 2 amps at 28VDC resistive load.
During normal operation, the fault relay will energize
after entering Run Mode. Whenever the PanelMate
unit detects a communication error or system
failure, the fault relay will be de-energized. It is also
possible to de-energize the fault relay whenever an
alarm condition occurs. You can set the fault relay to
de-energize on alarms by using the System
Parameters Table. Refer to the System Parameters
topic in the Configuration Software Online Help and
in the Configuration Editor User's Guide for more
information.

The Audio Feedback Kit is an optional accessory to
your PanelMate unit. To connect the external 8 Ohm
speaker to your PanelMate unit, connect the
speaker to the Audio connector.

The Security Keyswitch connection is provided for
external security/password applications.

+

_

GND

Содержание PanelMate 5000 Series

Страница 1: ...PanelMate 5000 Series PanelMate Power Pro Cutler Hammer EXPRESS SETUP EXPRESS SETUP EXPRESS SETUP EXPRESS SETUP...

Страница 2: ...installation recommendations The Guide is available on the Cutler Hammer web site Panel cutout dimensions and stud torque limits are shown on the reverse side of this Express Setup sheet Stud nuts mu...

Страница 3: ...ate unit s serial port A transfer serial cable is provided with your PanelMate Configuration software Refer to your PanelMate Getting Started Manual for more information The fault relay may be wired i...

Страница 4: ...n the PanelMate Configuration Editor User s Guide Your PanelMate unit is sent without termination For serial port termination switch locations refer to Figure A Recommended termination for RS232 DH485...

Страница 5: ...er to your PanelMate Transfer Utility User s Manual Execute Diagnostics Enter Serial Transfer Mode Enter Network Transfer Mode Execute Diagnostics Calibrate Touchscreen Enter Serial Transfer Mode Ente...

Страница 6: ...crosshairs twice CANCEL PRESS AND HOLD EACH BOX ALONG EDGES FOR 1 SEC Pass 1 of 2 Touchscreen Calibration Program Copyright c Cutler Hammer 1996 All rights reserved 10 27 53 PanelMate Operation The m...

Страница 7: ...a level ESD Immunity Air IEC 1000 4 2 Level 4 15kV Contact IEC 1000 4 2 Level 4 8kV Radiated Immunity IEC 1000 4 3 10V m 27mHz to 1GHz 80 AM modulation Conducted Immunity IEC 1000 4 6 10V from 150kHz...

Страница 8: ...n selectable for RS232 RS422 or RS485 2 signal levels Weight 16 Lbs 17 Lbs with high speed interface installed P N 01 00472 00 Cutler Hammer 173 Heatherdown Drive Westerville OH 43081 614 882 3282 Tec...

Страница 9: ...ort this cutout template Always check your dimensions prior to cutting your panel Care should be taken when tightening the nuts The fasteners must be tightened enough to obtain a proper seal but not o...

Отзывы: