Installation

Unpacking

Parts Checklist

Mounting

Carefully remove all equipment from the packing
cartons and inspect all parts for damage in
shipment. Check packing cartons for all items
shown on the packing list. Keep the cartons and
packing materials for future shipment.

If there is equipment damage due to shipment,
report the damage to the carrier who delivered the
equipment. Note: The Interstate Commerce
Commission has a time limit on reporting concealed
damage.

Your packing carton contains one parts kit
containing:

1 Packet of mounting nuts and washers

2 Two-terminal connectors (audio output &

security keyswitch)

1 Three-terminal connector (24VDC power)

1 Four-terminal connector (fault relay)

Your PanelMate unit is designed for Type 4, 4X, and
12 installations when properly mounted in a
correspondingly-rated enclosure.

Proper installation and enclosure sizing is essential
to ensure long life and trouble-free operation.

Refer to Cutler-Hammer's PanelMate Installation
Guide for installation recommendations. The Guide
is available on the Cutler-Hammer web site:

Panel cutout dimensions and stud torque limits are
shown on the reverse side of this Express Setup
sheet.

Stud nuts must be tightened enough to

obtain a proper seal, but not over-tightened
to the point where the threads are stripped
or the gasket is rendered useless. Always
use a torque wrench when installing your
PanelMate unit.

!
!

!
!

Your

PanelMate unit should always be mounted in a
vertical position. Flat or angled mounting positions
will severely shorten the unit's life.

www.cutlerhammer.eaton.com/automation

Note:

Safety Considerations

This equipment is suitable for Class I, Division 2,
Groups (A,B,C,D) or non-hazardous locations only.

EXPLOSION HAZARD. SUBSTITUTION OF

COMPONENTS MAY IMPAIR SUITABILITY FOR

CLASS I, DIVISION 2.

RISQUE D'EXPLOSION. LA SUBSTITUTION DE

COMPOSANTS PUET RENDRE CE MATERIAL

INACCEPTABLE POUR LES EMPLACEMENTS

DE CLASSE I, DIVISION 2.

EXPLOSION HAZARD. DO NOT REPLACE

COMPONENTS UNLESS POWER HAS BEEN

SWITCHED OFF OR AREA IS KNOWN TO BE

NON-HAZARDOUS.

RISQUE D'EXPLOSION. COUPER LE COURANT

OU S'ASSURER QUE L'EMPLACEMENT ES

DESIGNE NON DANGEREUX AVANT DE

REPLACER LE COMPOSANTS.

Содержание PanelMate 5000 Series

Страница 1: ...PanelMate 5000 Series PanelMate Power Pro Cutler Hammer EXPRESS SETUP EXPRESS SETUP EXPRESS SETUP EXPRESS SETUP...

Страница 2: ...installation recommendations The Guide is available on the Cutler Hammer web site Panel cutout dimensions and stud torque limits are shown on the reverse side of this Express Setup sheet Stud nuts mu...

Страница 3: ...ate unit s serial port A transfer serial cable is provided with your PanelMate Configuration software Refer to your PanelMate Getting Started Manual for more information The fault relay may be wired i...

Страница 4: ...n the PanelMate Configuration Editor User s Guide Your PanelMate unit is sent without termination For serial port termination switch locations refer to Figure A Recommended termination for RS232 DH485...

Страница 5: ...er to your PanelMate Transfer Utility User s Manual Execute Diagnostics Enter Serial Transfer Mode Enter Network Transfer Mode Execute Diagnostics Calibrate Touchscreen Enter Serial Transfer Mode Ente...

Страница 6: ...crosshairs twice CANCEL PRESS AND HOLD EACH BOX ALONG EDGES FOR 1 SEC Pass 1 of 2 Touchscreen Calibration Program Copyright c Cutler Hammer 1996 All rights reserved 10 27 53 PanelMate Operation The m...

Страница 7: ...a level ESD Immunity Air IEC 1000 4 2 Level 4 15kV Contact IEC 1000 4 2 Level 4 8kV Radiated Immunity IEC 1000 4 3 10V m 27mHz to 1GHz 80 AM modulation Conducted Immunity IEC 1000 4 6 10V from 150kHz...

Страница 8: ...n selectable for RS232 RS422 or RS485 2 signal levels Weight 16 Lbs 17 Lbs with high speed interface installed P N 01 00472 00 Cutler Hammer 173 Heatherdown Drive Westerville OH 43081 614 882 3282 Tec...

Страница 9: ...ort this cutout template Always check your dimensions prior to cutting your panel Care should be taken when tightening the nuts The fasteners must be tightened enough to obtain a proper seal but not o...

Отзывы: