background image

4

INM9466 rev 3

PC PACKAGE REQUIREMENTS

In order to run the package on a PC, the following minimum system configuration is required:-

• 

Pentium® 3 Processor or Equivalent

• 

256 Mb RAM minimum

• 

Windows® 98(or higher)

• 

Serial Communications Port

SOFTWARE INSTALLATION

Note

Sections 5 through to 15 are relevant only if you require the 9466-ET switch 

to operate in the 

managed

 mode .

The 9466-ET Ethernet switch management software is provided on a CD along with the hardware.  
If the CD is not available for some reason, download the software from the Industrial Networks 
section of our website at www.mtl-inst.com. 

If installing from the CD

 - Place the CD into the CD or DVD drive on a PC. If the Setup 

application does not Autorun then use Start|Run from the Windows menu and run the 

setup.exe 

application on the CD to launch the installation program. 

If installing from downloaded files

 - Unzip the file into a temporary directory, then run the  

resulting 

setup.exe 

application in that directory to launch the installation program.

In either case, this is a conventional installation program that requires the user to specify a 
destination directory for the application software, after which the setup will continue. Follow the 
on-screen instructions to complete the installation.

COMMUNICATING WITH THE 9466-ET 

6 .1  In the safe area

Connect the 9466-ET Ethernet Switch to your PC using the CAB9466 RS communications lead that 
is supplied with the switch. The 9-pin minature D-type connector should be plugged into a Serial 
Communications (COM) port on the PC and the other end of the cable should be plugged into the 
RS232 connector on the front panel of the 9466-ET Switch. Apply 12V dc power to the switch and 
then open the Configuration Software application.

6 .2  In the hazardous area

If the 9466-ET is installed in an intrinsically safe system in the hazardous area then the 9461-ET 
Etthernet Gateway is required to connect to the 9466-ET from the safe area. Set up the 9461-ET as 
instructed in its manual

LAUNCHING THE PROGRAM

To run the program, double click the 9466-ET Management icon. A splash screen, of the type shown 
below, will appear which displays the version number of the software.

Содержание MTL9466-ET

Страница 1: ...MTL9466 ET Managed Ethernet Switch September 2016 INM 9466 rev 3 Instruction manual MTL intrinsic safety solutions ...

Страница 2: ...ATION OF CONFORMITY A printed version of the Declaration of Conformity has been provided separately within the original shipment of goods However you can find a copy of the latest version at http www mtl inst com certificates ...

Страница 3: ...ATING WITH THE 9466 ET 4 6 1 In the safe area 4 6 2 In the hazardous area 4 7 LAUNCHING THE PROGRAM 4 8 MAIN SCREEN 5 8 1 Menu Bar 5 9 VLAN 6 10 RATE LIMIT 7 11 MIRRORING 8 12 MIB COUNTERS 9 13 STATIC MAC ADDRESSES 9 14 DYNAMIC MAC ADDRESSES 10 15 DOWNLOADING NEW SOFTWARE 10 16 ENVIRONMENTAL 11 17 WASTE REMOVAL INFORMATION 11 18 ACCESSORIES 11 19 APPROVALS 12 20 FM CERTIFICATION INFORMATION 12 21 ...

Страница 4: ...iv INM9466 rev 3 THIS PAGE IS LEFT INTENTIONALLY BLANK ...

Страница 5: ... cables Broadcast storm protection eliminates network overload caused by excessive broadcast and multicast packets Intelligent Routing Automatic address learning aging and migration Supports IEEE 802 3 10Base T 100Base TX IEEE 802 1q Tag Port based VLAN Quality of Service QoS priority Programmable Managed features Serial port VLAN Rate Limiting Port Mirroring etc DIN rail mounting module Note PoEx...

Страница 6: ...a the serial RS232 TTL port either in the Safe Area using a PC or in the Hazardous Area using the 9461 ET Ethernet Gateway as its host processor Features such as Programmable Rate Limiting VLAN support Port Mirroring and Forced Speed and Duplex settings may be configured in this way if required The 9461 ET module can also perform its usual function of a serial communications gateway eg serial Modb...

Страница 7: ...connection 6 12V dc in PoEx Port 1 see Note 2 7 0V 8 12V dc in PoEx Port 2 see Note 2 9 0V 10 12V dc in PoEx Port 3 see Note 2 11 0V 12 12V dc in PoEx Port 4 see Note 2 13 0V 14 12V dc in PoEx Port 5 see Note 2 15 0V Note 1 Terminals 1 2 and 3 4 are linked internally 2 For PoEx connect IS supplies to terminals 6 to 15 as required WARNING The supply for PoEx must be derived from a suitably certifie...

Страница 8: ...ch the installation program In either case this is a conventional installation program that requires the user to specify a destination directory for the application software after which the setup will continue Follow the on screen instructions to complete the installation 6 COMMUNICATING WITH THE 9466 ET 6 1 In the safe area Connect the 9466 ET Ethernet Switch to your PC using the CAB9466 RS commu...

Страница 9: ...n times out after approximately 5 minutes After modifications are made they need to be sent or saved to the switch Sending to the switch is only temporary and will be lost on a power down whereas saving is permanent Also on this and every page is the status bar at the bottom This records the last event that has happened Events can include Switch Offline Settings Saved or Sent etc 8 1 Menu Bar At t...

Страница 10: ... ET supports 16 active VLANs Any one of the 4096 available VLAN ID s can be specified as one of the active VLANs If a non tagged packet or a null VID packet is received the 9466 ET will use the ingress ports programmable default VID for look up Click Enabling Value Editing and enter the password In order to use the 802 1Q VLAN it must be enabled by selecting the Enabled 802 1Q VLAN checkbox As can...

Страница 11: ...be programmed up to the line rate in increments of 32 768 bps On the above screen the rates can be set in Mbps for both low and high priority messages To limit High priority messages ensure the Disable Priority check boxes are not selected The rate limits can be enabled by selecting the check boxes on the appropriate limit The priority for each port can be set to be Diffser 802 1P Port Based or No...

Страница 12: ... s Transmit only port mirroring Information transmitted on a port can be mirrored to another port s Receive and Transmit port mirroring Information received on a port and information transmitted on a port can be mirrored to another port s Specify the port s by checking the boxes for the ports In the first column Mirror Port you specify the ports to receive the mirrored information then check boxes...

Страница 13: ...TIC MAC ADDRESSES The 9466 ET offers 8 static MAC settings These can be allocated a VLAN ID or set at 0 to allow MAC lookup Click Enabling Value Editing and enter the password The port to forward the messages for the static MAC can be selected and whether or not to override the spanning tree Static MACs can be activated or deactivated using the checkbox on the far right These settings can easily b...

Страница 14: ...SOFTWARE The 9466 ET has the facility to upgrade its software To begin this action select the Update Switch Software menu bar option which will bring up the password dialog box After password entry a file selection window will appear Select the software file you wish to load into the 9466 ET Switch and click the Open button The following warning will appear on screen Click No if you need to return...

Страница 15: ... of correctly you will be helping to prevent potentially negative consequences for the environment and human health which could otherwise be caused by incorrect waste handling of this product For more detailed information about the take back and recycling contact Eaton s MTL product line 18 ACCESSORIES For interconnecting the 9460 ET range of products we offer approved RJ45 Cat5e UTP cables in var...

Страница 16: ...g chemical vapours of the Ketone or Ester families 21 ATEX IECEx CERTIFICATION INFORMATION The following information is in accordance with the Essential Health and Safety Requirements Annex II of the EU Directive 2014 34 EU the ATEX Directive safety of apparatus and is provided for those locations where the ATEX Directive is applicable General a This equipment must only be installed operated and m...

Страница 17: ...ure shall also comply with the requirements of Clauses 7 and 8 of EN 60079 0 2006 2 The connectors do not meet the ingress protection rating of IP20 therefore this shall be taken into consideration during the installation of the 9400 Series Ethernet Modules when used with Group II gases and each module shall be provided with an enclosure that is commensurate with the environment into which it is i...

Страница 18: ...14 INM9466 rev 3 Replace this page with the first page of the PDF of the Control Drawing ...

Страница 19: ...15 INM9466 rev 3 Replace this page with the second page of the PDF of the Control Drawing ...

Страница 20: ...ia No 36 Nehru Street Off Old Mahabalipuram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Italia srl Via San Bovio 3 20090 Segrate Milano Italy Tel 39 02 959501 Fax 39 02 95950759 E mail chmninfo eaton com JAPAN Cooper Crouse Hinds Japan KK MT Building 3F 2 7 5 Shiba Daimon Minato ku Tokyo Japan 105 0012 Tel 81...

Отзывы: