background image

IB515007EN

Installation instructions – LED Recessed Canopy

Instructions d’installation – Luminaire DEL pour voûte encastrée

Instrucciones de instalación – LED empotrada en fascia

Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this 

product must be performed by a qualified electrician. This product must be installed in accordance 

with the applicable installation code by a person familiar with the construction and operation of the 

product and hazards involved. 

Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting 

any maintenance. Disconnect power at fuse or circuit breaker.

Risk of Fire- Refer to product label for specific minimum supply conductor requirements.

Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.

Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.

Failure to comply with these instructions may result in death, serious bodily injury and property damage.

WARNING

DISCLAIMER OF LIABILITY: Eaton assumes no liability for damages or losses of any kind that may arise from the 

improper, careless, or negligent installation, handling or use of this product.

 

NOTICE:

 Green ground wire provided in proper location. Do not relocate.

ATTENTION Receiving Department:

 Note actual fixture description of any shortage or noticeable damage on 

delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be 

filed within 15 days of delivery. All damaged material, complete with original packing must be retained.

Safety

: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and 

ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under 

installation section. 

APPLICATIONS

: This lighting fixture is designed for outdoor lighting services, and should not be used in area 

of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to 

installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation 

and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and 

maintained according to the following recommendations.

Содержание McGraw-Edison LRC LED Recessed Canopy

Страница 1: ...s no liability for damages or losses of any kind that may arise from the improper careless or negligent installation handling or use of this product NOTICE Green ground wire provided in proper locatio...

Страница 2: ...he Ceiling Opening is Less Than 14 Square Note N Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area APPLICATIONS Minimum 90 C Supply Conductors...

Страница 3: ...into the hole of the driver box housing The conduit connector must have a gasket on outside for sealing Tighten the connector with locknut on the inside of the driver box Make sure the connector is sn...

Страница 4: ...of wires through the grommet Push the grommet into the conduit opening 9 Secure water tight conduit with connector and incoming power leads into the hole of the driver box housing The conduit connect...

Страница 5: ...ntes haute temp rature ambiante Il doit tre rang dans un endroit sec en attendant son installation N exposez pas le luminaire la pluie la poussi re ou d autres conditions ambiantes avant l installatio...

Страница 6: ...ser le luminaire sur les lentilles et de ne pas le soulever en posant vos mains sur les lentilles APPLICATIONS Conducteurs d alimentation de 90 C minimum lorsque les raccords sont effectu s l ext rieu...

Страница 7: ...fil fournis Assurez vous que le fil passe sur au moins 7 6 cm 3 po dans le passe fil Poussez ensuite le passe fil dans l ouverture du conduit 8 Fixez fermement le conduit tanche l eau avec le connect...

Страница 8: ...5 Retournez le luminaire et desserrez les quatre 4 vis de la porte Mettez soigneusement la porte de c t et vous assurant de ne pas rafler la lentille de verre et la porte peinte Note N Ne retirez pas...

Страница 9: ...2 montants diagonaux comme guide pour rep rer les vis de la porte Figure 6 Serrez compl tement les vis un couple de 1 7 Nm 15 po lb 19 Nettoyez seulement la surface en verre apr s avoir install la por...

Страница 10: ...limitada o en lugares cerrados a alta temperatura ambiente Debe almacenarse en un lugar seco antes de la instalaci n No exponga el accesorio de iluminaci n a la lluvia el polvo u otras condiciones amb...

Страница 11: ...ota N Se debe tener cuidado de no colocar la luminaria sobre los lentes pticos ni levantarla por el rea del lente APLICACIONES Conductores de suministro de 90 C como m nimo cuando las conexiones se re...

Страница 12: ...ico de 1 2 inserte los cables de alimentaci n entrantes en los orificios de los cables en el ojal provisto Aseg rese de tener al menos 3 de cables a trav s del ojal Empuje el ojal en la abertura del c...

Страница 13: ...atro tornillos de cabeza Philip Ponga la puerta y los tornillos a un lado Nota N El interior de la caja tiene un empaque protector alrededor del troquel deje esto intacto para proteger al controlador...

Страница 14: ...adhesiva 17 Fije la correa a la puerta desatornillando la tuerca de la puerta colocando la correa en el perno y apriete la tuerca nuevamente Figura 6 18 Atornille la puerta en la luminaria mientras se...

Страница 15: ...15...

Страница 16: ...y and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particula...

Отзывы: