NOTE
The ePDU is capable of sending out two types of SNMP traps:
S
PDU−specific traps
, which are sent if configured in Event Log setting, while the PDU MIBs should be
self explanatory.
S
IPMI PET (Platform Event Traps)
, which are generated in alert configuration and sent out in
IPMI−specific formats, containing raw data.
Details of such traps can be referenced at:
http://www.intel.com/design/servers/ipmi/pdf/IPMIv2_0_rev1_0_E3_markup.pdf
(http://www.intel.com/design/servers/ipmi/pdf/ipmiv2_0_rev1_0_e3_markup.pdf) (Chapter 17.16) and
http://download.intel.com/design/servers/ipmi/PET100.pdf
(http://download.intel.com/design/servers/ipmi/pet100.pdf).
Setting Up Event Logging
By default, the ePDU captures certain system events and saves them in a local
(internal) event log. You can expand the scope of the logging to also capture events in
the NFS, SMTP, and SNMP logs.
Configuring the Local Event Log
To configure the local event log:
1.
Select
Device Settings
, and then select
Event Log
. The Event Log Settings page
displays. The
Local Logging
panel displays first. This panel controls the local event
log. See Figure 63.
Figure 63. Local Logging Panel
2.
The local event log is enabled by default. To turn it off, clear the
Local Logging
Enabled
check box.
3.
By default, 20 log entries are listed on each page of the local event log when it is
displayed on your screen. To change this, type a different number in the
Entries
shown per page
field.
4.
To clear all events from the local event log:
S
Click the
Clear
button. The button changes to
Really Clear
and you are
prompted to click it only if you are certain you want to clear the log.
S
Click
Really Clear
to complete the clear operation, or click
Cancel
to terminate
it.
Содержание Managed ePDU
Страница 1: ...Managed ePDU User s Guide...
Страница 4: ......
Страница 10: ...TABLE OF CONTENTS EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 vi...
Страница 16: ...SAFETY WARNINGS EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 6...
Страница 20: ...RACK MOUNTING THE EPDU EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 10...
Страница 98: ...USING THE WEB INTERFACE EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 88...
Страница 104: ...USING THE CLP INTERFACE EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 94...
Страница 116: ...USING THE IPMI TOOL SET EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 106...
Страница 120: ...APPENDIX B EVENT TYPES EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 110...
Страница 127: ...APPENDIX D SPECIFICATIONS EATON Managed ePDUt User s Guide S 164201xxx Rev 1 DRAFT 10 OCT 2008 118...
Страница 128: ......
Страница 129: ...164201xxx1 164201xxx 1...