4. Transport and storage 

4.1 Packaging and transport 

 

Remove cardboard boxes, wooden boxes, foil, 

fixing material

 

Proper disposal in accordance with the 

national directives 

 

Transport damages must be immediately announced to 

the carrier

 

Due to the large dimensions and mass of Hydrokraft 

pumps, adequate lifts and sling gears must be used for 

installation and transport

 

The general safety instructions must be respected 

when transporting!

 

Piping and pump or other installations must not be 

used as sling gears

 

Always transport Hydrokraft pumps without hydraulic 

medium. Due to the production test carried out by the 

manufacturer, oil residues might be in the product

4.1.1 Health risk and risk of damage

 

Health Risk: Never stand or walk under 

suspended loads!

 

Risk of Damage: Hard hits to pump and especially 

shaft can damage the pump (especially bearings can be 

pre-damaged) 

Never set or place pump on the drive shaft! 

Never use hammer or similar tools to mount coupling 

on drive shaft!

 

Ensure that lifting device (fork lift truck or similar) has 

adequate lifting capacity!

 

Ensure that lifting straps/chains or ring screws has 

adequate lifting capacity and are without damage!

4.1.2 Dimensions and weights

Estimated weights for basic pumps with DF,LR,ST,SP and 

DP control, without aux.pumps

Model

PF/VW 

130/180

PF/VW 

250

PF/VW 

360

PF/VW 

500

PF/VW 

750

Mass

m

kg 130/140 212

220

340

395

Please be aware that mass can vary depending on pump 

options significantly. 

For exact mass data contact your Eaton Hydrokraft 

Technical Support team or weight pump separately 

before lifting.

For dimension information please have a look in 

 appropriate documentation (installation drawing, 

product catalogue)

4.1.3 Transport with lifting straps or chains

Hydrokraft PVW pumps with SP, DP or ES control are 

foreseen to be transported with lifting straps or chains. 

Please use appropriate lashing lugs provided together 

with pump.

4.1.4 Transport with ring screw

Hydrokraft PVW pumps with DF, LR or ST control are fore-

seen to be transported with lifting straps or chains. Please 

use appropriate ring screw provided together with pump.

Содержание Hydrokraft PVW 250

Страница 1: ...Hydrokraft Operation Manual PVW 250 360...

Страница 2: ...cal installation 20 5 9 Case drain and Case pressure 21 5 10 Suction line 22 5 11 Atmospheric pressure 22 5 12 Acceleration of oil in suction line 22 5 13 Shaft coupling immersed pump 23 5 14 Installa...

Страница 3: ...ION MANUAL PVW 250 360 E PUIO_II001 E April 2021 www eaton com 7 TROUBLESHOOTING 30 8 MAINTENANCE AND REPAIR 33 9 EXTENSION AND CONVERTING 34 10 DISASSEMBLY AND REPLACEMENT 34 11 DECOMMISSIONING 34 12...

Страница 4: ...Please consider the maximum operating pressure in the technical documentation Operating in an explosion risk environment Eaton Hydrokraft piston pumps cannot be operated in an explosion risk environme...

Страница 5: ...ed Cut the energy supply Secure against restart Relieve pressure from the system including all hydraulic accumulators kneel or prop up raised loads relieve rest energy Make sure the system is at zero...

Страница 6: ...ursting elements Can be consequence of Overcharge of the components e g following too high pressure or pressure peaks Old material Inadequate elements 2 10 Noise emission Noise emission is not only ca...

Страница 7: ...epending on the swashplate angular position the displacement of the pump increases or decreases i Control Control Piston Swash Angle Sensor Indicator Thru Drive Option Valve Plate Cylinder Block Swash...

Страница 8: ...W 250 360 E PUIO_II001 E April 2021 www eaton com Typical section of open loop PVW pump Definition of shaft direction of rotation swash angle direction and actuator piston movement Optically indicated...

Страница 9: ...limited mechanically to between 50 and 100 by a screw A DF controlled pump can be combined with following options Pilot operated by proportional valve with el card or with on board electronis Pilot op...

Страница 10: ...control main stage 20 bar approx and power loss of the pump Maximum pump flow can be limited mechanically to between 50 and 100 by a screw A LR controlled pump can be combined with all pressure limit...

Страница 11: ...tely 1 of end value The SP control can also be combined with hydromechanical relief valves for pressure and or power control Maximum pump flow can be limited mechanically to between 50 and 100 by a sc...

Страница 12: ...combined with hydromechanical relief valves for pressure and or power control Maximum pump flow can be limited mechanically to between 50 and 100 by a screw A B System port L1 L2 Drain port L3 Vent p...

Страница 13: ...mately 1 of end value ST controlled pumps starts at max displacement They can work with internal pilot oil supply only but require a min operation pressure of 25 bar for operation Below this min press...

Страница 14: ...epend on the ratio selected and on the fixed speed of the servo motor with the result that once the control is specified and built response time are not variable in operation Explosion Protection vers...

Страница 15: ...ecific unit if different to Vg max Allowed kinematic viscosity range for continuous operation Workorder Serial Number V0ABCD ABCD consecutively number Type Short form modelcode of pump Manufacturing d...

Страница 16: ...pressure n 1200 rev min n 1500 rev min n 1800 rev min pcase bar 3 2 2 6 2 0 2 8 2 2 1 6 2 8 2 2 1 6 2 35 1 85 1 35 2 1 1 7 Drive PF VW 130 180 PF VW 250 PF VW 360 PF VW 500 PF VW 750 Driving torque pN...

Страница 17: ...sure overpressure pcase psi n 1200 rev min 46 40 40 34 30 n 1500 rev min 38 32 32 27 25 n 1800 rev min 29 23 23 20 Drive PF VW 130 180 PF VW 250 PF VW 360 PF VW 500 PF VW 750 Driving torque pN 5075 ps...

Страница 18: ...e drive shaft Never use hammer or similar tools to mount coupling on drive shaft Ensure that lifting device fork lift truck or similar has adequate lifting capacity Ensure that lifting straps chains o...

Страница 19: ...ons with extended protection for inner parts preliminary note pumps should be stored horizontally It is recommended to rotate pumps manually every 6 months for some turns and fill spray some corrosion...

Страница 20: ...lic components and the entire machine installation Please consider the control and replacing intervals of the filter In case of a later installation of supplementary filters ensure an arrangement whic...

Страница 21: ...nded No side load must be applied to the drive shaft of Hydrokraft pumps and motors In some cases limited side loads are permissible under specific conditions Contact Hydrokraft technical support for...

Страница 22: ...ynamic flow impacts If a collecting line is used a suitable diameter must be chosen Depending on length of drain line flow velocity should not exceed 1 m s at max drain flow Recommeded drain line size...

Страница 23: ...draw fluid across them further lowers the inlet pressure 5 11 Atmospheric pressure The sensitivity of the pumps to inlet conditions is even more relevant at greater altitudes and lower atmospheric pre...

Страница 24: ...pposite side of the baffle Take care that inlet pressure at port L3 does not exceed 16 bar otherwise permissible values of shaft seal pressure 2 2 bar overpressure at 1500 rpm might be exceeded and sh...

Страница 25: ...ol requires no pilot oil flow eg ES or manual Flow controls so that pilot flow cannot be used for case bearing flushing Active Bearing Flushing should be no less than 1 of maximum pump flow Take care...

Страница 26: ...he indications of the manufacturer in order to attempt a steady purity level Unless otherwise specified the rinsing of the assembled installation must be carried out in accordance with ISO 23309 Check...

Страница 27: ...d the rinsing of the assembled installation must be carried out in accordance with ISO 23309 6 7 Fluid cleanliness Hydrokraft pumps are rated in anti wear petroleum fluids with a contamination level o...

Страница 28: ...ous inverse rotation of pump will cause cavita tion and will lift the piston slipper off the swash plate Shoulder of piston shoe will be pushed against retaining ring causing at first increasing clear...

Страница 29: ...ing torques of tie rods Size 130 180 280 Nm 250 360 280 Nm 500 750 600 Nm 6 14 5 Metal plugs male stud per ISO 1179 BSPP with elastomeric profile sealing thread friction coefficients ges 0 125 Size AL...

Страница 30: ...5 Other installation torque specification 6 15 1 Purpose Below references provide tables of recommended tightening torque for metal plugs fittings ISO metric socket head cap screws SHCS valves etc rel...

Страница 31: ...entrainment 4 Reservoir air vent plugged 5 Pump rotation or speed incorrect 6 Oil viscosity too high 7 Oil viscosity too low 8 Filter or strainer too dirty or filter too small 9 Pump out of line with...

Страница 32: ...l type are as per fluid recommendations See chp 3 4 Technical data 6 5 Hydraulic fluids 7 7 Filter or strainer too dirty or filter too small Filter and strainer must be kept clean enough to permit ade...

Страница 33: ...drain lines 7 17 Reservoir too small may vortex or fail to provide adequate cooling Replace with larger reservoir or install cooler 7 18 Valve deposits Check valve in regard of function and cleanlines...

Страница 34: ...en 3000h and 16000h Depending on operation conditions The life time of the Hydrokraft pump is limited by service life of the build in bearings Life time of bearings can be requested based on load cycl...

Страница 35: ...essure free Make sure the temperature of the Hydrokraft pump is cold enough to touch safe Use a collector to collect resigning hydraulic fluid IMPORTANT Save the environment Remove all electric cable...

Страница 36: ...ph 16 D 61273 Wehrheim Tel 49 0 6081 103 302 Fax 49 0 6081 103 342 2021 Eaton All Rights Reserved Publication No E PUIO II001 E April 2021 Eaton is a registered trademark All trademarks are property o...

Отзывы: