Installation Notes
The panel thickness should be 5 mm
or less for proper mounting.
Installation Method:
Step 1:
Ensure the pre-installed waterproof gasket is
present and properly aligned.
Step 2:
Insert fasteners into the operator interface slots.
All should be finger tight initially.
Step 3:
Torque all fasteners to 6.17lb-inch (0.7N-M)
Over torque may cause damage to the operator
interface housing.
Step 4:
Maintain a minimum spacing of 60mm from the
back of the operator interface ventilation holes.