Operation 

 

 

 HMiSoft Screen Editor software 
is the only software authorized 
for creation and editing of 
applications to be run on 
Eaton’s 

HM

i

 

and 

HM

i

 

VU series 

hardware. 

 

To avoid personal injury and 
equipment damage, the 

HM

i

 

applications should be designed 
so that a communication loss 
results in a system fail safe 
state.     

 

It is good practice to backup the 

HM

i

 application in the event that 

the operator interface is 
damaged, the application is lost 
or inadvertently deleted. 

 

 

 

 Modify wiring during operation 
may result in electric shock or 
personal injury. 

 

 Using a sharp or pointed object 
to activate screen controls may 
result in damage to the 
touchscreen and improper 
operation. 

Wiring Method 

 

 

 

Observe voltage specifications.   
Failure to do so observe this 
caution may result in electric 
shock or fire as well as damage 
to the unit. 

 

Remove the terminal block from 
the operator interface before 
wiring. 

 

 Insert only one wire into each 
terminal on the terminal block. 

Communication Wiring 

 

 

Comply with communication 
wiring and grounding 
specifications for the network 
being used.       

 

All power cables should be 
placed in separate conduits from 
communication cables in order 
to avoid noise and interference. 

 

Maintenance and Inspection 

 

 

 Electrical shock and damage to 
unit may result from contact with 
any internal electronic 
assemblies.     

 

First remove power and then 
disconnect the terminals to avoid 
electrical shock and damage to 
unit.   

 

 

Accessing the unit’s internal 
electric assemblies will void the 
warranty. In addition, an electrical 
charge with hazardous voltages 
may reside in the operator 
interface after power has been 
removed for 10 minutes or longer 
which may result in electrical 
shock and damage to the unit. 

 

 Turn the power off before 
changing backup battery and 
check system settings after 
changes are made. Note that the 
application and all data will be 
cleared after a battery change.     

 

 Obstruction of ventilation holes 
during operation may result in 
malfunction caused by 
overheating. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание HMIVU04CUNBE

Страница 1: ...tion Leaflet Instruction Leaflet IL04801003E Effective March 2013 Contents Description Page Preface 1 Safety Precautions 1 Installation 3 Wiring 4 Basic Inspection 4 Hardware Features 7 Panel Cut Out...

Страница 2: ...this quick start guide may be revised without notice Please consult an authorized distributor or download the most up to date version at www eaton com oi Safety Precautions Carefully note and observe...

Страница 3: ...rom the operator interface before wiring Insert only one wire into each terminal on the terminal block Communication Wiring Comply with communication wiring and grounding specifications for the networ...

Страница 4: ...nstalled waterproof gasket is present and properly aligned Step 2 Insert fasteners into the operator interface slots All should be finger tight initially Step 3 Torque all fasteners to 6 17lb inch 0 7...

Страница 5: ...s necessary as they may loosen due to vibration and varying temperatures Ensure that oil water metallic particles or any foreign objects do not fall inside the operator interface ventilation slots and...

Страница 6: ...MIVU07CUNBE COM1 Port Supports Flow Control PIN Contact RS 232 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 Note Blank No Connection COM2 and COM3 Port PIN MODE1 MODE2 MODE3 COM2 COM3 COM2 COM3 COM2 COM3 RS...

Страница 7: ...abled Note3 When COM2 port is used for RS 422 with flow control COM3 Port pins 1 4 6 and 9 are used for the signals RTS CTS RTS and CTS as shown in brackets COM3 Port PIN MODE1 MODE2 MODE3 RS 232 RS 4...

Страница 8: ...HMi VU Series Instruction Leaflet EATON CORPORATION www eaton com 7 Hardware Features HMIVU04CUNBE Front View A Power LED Indicator Lights in green when power is applied B Touch Screen Display B A...

Страница 9: ...ION www eaton com 8 HMIVU04CUNBE Rear View A USB Slave D Ethernet Port B USB Host E COM1 Note1 C System Button F Power Input Terminal N O T E 1 Refer to the Pin Definition for Communications section f...

Страница 10: ...HMi VU Series Instruction Leaflet EATON CORPORATION www eaton com 9 HMIVU06CUNB1 Front View A Power LED Indicator Lights in green when power is applied B Touch Screen Display A B...

Страница 11: ...ton com 10 HMIVU06CUNB 1 Rear View A Power Input Terminal E USB Host B COM2 and COM3 Note1 F USB Slave C COM1 G System Button D Battery Cover N O T E 1 Refer to the Pin Definition for Communications s...

Страница 12: ...HMi VU Series Instruction Leaflet EATON CORPORATION www eaton com 11 HMIVU07CUNBE Front View A Power LED Indicator Lights in green when power is applied B Touch Screen Display A B...

Страница 13: ...w A Power Input Terminal F USB Host B COM2 and COM3 Note1 G USB Slave C COM1 H System Button D Battery Cover I Ethernet Port E Memory Card Slot J Audio Output Port N O T E 1 Refer to the Pin Definitio...

Страница 14: ...is applied B Operation LED Indicator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one...

Страница 15: ...Power Input Terminal B COM3 Two LED indicate Read or Write status during the communication process C COM2 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Et...

Страница 16: ...is applied B Operation LED Indicator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when on...

Страница 17: ...put Terminal B COM2 Two LED indicate Read or Write status during the communication process C COM3 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet P...

Страница 18: ...ruction Leaflet EATON CORPORATION www eaton com 17 Panel Cut Out HMIVU04CUNBE HMIVU06CUNB1 6 79 172 4 7 24 184 5 67 144 0 063 1 6 0 24 6 5 21 132 4 HMIVU07CUNBE 7 24 184 5 67 144 5 21 132 4 6 79 172 4...

Страница 19: ...eries Instruction Leaflet EATON CORPORATION www eaton com 18 HMIVU08CUNBE 0 063 1 6 0 24 6 8 94 227 1 6 85 174 1 8 64 219 4 6 56 166 5 HMIVU10WCUNBE 10 71 272 7 88 200 0 063 1 6 0 24 6 10 29 261 3 7 4...

Страница 20: ...System Real Time OS MCU 32 bit RISC Micro controller NOR Flash ROM Flash ROM 128 MB OS System 30MB Backup 16MB User Application 82MB SDRAM 64Mbytes Backup Memory 16Mbytes Sound Effect Output Buzzer M...

Страница 21: ...tion Temp 0 o C 50 o C Storage Temp 20 o C 60 o C Ambient Humidity 10 90 RH 0 40 o C 10 55 RH 41 50 o C Pollution Degree 2 Vibration IEC 61131 2 compliant 5Hz f 8 3Hz Continuous 3 5mm 8 3Hz f 150Hz Co...

Страница 22: ...value of the power consumption indicates the electrical power consumed by HMi only without connecting to any peripheral devices In order to ensure the normal operation it is recommended to use a powe...

Страница 23: ...HMi VU Series Instruction Leaflet...