Eaton HMIVU04CUNBE Скачать руководство пользователя страница 2

 
 
 
 
 

HM

i

 VU Series Instruction Leaflet 

EATON CORPORATION

 www.eaton.com      1 

Preface 

Thank you for purchasing Eaton’s 

HM

i

 

VU 

series operator interface. This quick start 

guide will be helpful in the installation, wiring 

and inspection of your Eaton operator 

interface. Before using the product, please 

read this quick start guide to ensure correct 

use. You should thoroughly understand all 

safety precautions before proceeding with the 

installation, wiring and operation.    Please 
observe the following precautions:   

 

Install the product in a clean and dry 

location free from corrosive and 
flammable gases or liquids. 

 

Ensure that all wiring instructions and 

recommendations are followed. 

 

Ensure that the operator interface is 

correctly connected to a ground. The 
grounding method must comply with 
the electrical standard for the country 
of final installation (NFPA 70: National 
Electrical Code, 2005 Ed). 

 

Do not modify or remove wiring when 

power is applied to the operator 
interface. 

 

Do not touch the power supply during 

operation or it may cause electric 
shock. 

 

For the information on HMiSoft 

installation and use, please refer to 
the HMiSoft manual at 

www.eaton.com/oi

.   

If  you  have  any  questions  during  operation, 
please  contact  an  authorized  local  distributor 
or Eaton sales representative. The content of 
this  quick  start  guide  may  be  revised  without 
notice. 

Please 

consult 

an 

authorized 

distributor  or  download  the  most  up  to  date 
version at 

www.eaton.com/oi

.

 

 

 

 

Safety Precautions 

Carefully note and observe the following 

safety precautions when receiving, inspecting, 

installing, operating, maintaining and 

troubleshooting. The following words, 

DANGER, WARNING and STOP are used to 
mark safety precautions when using Eaton’s 
operator interface. Failure to observe these 

precautions may void the warranty! 

Installation 

 

 

 Do not install the product in a 
location that is outside the stated 
specification for the operator 
interface. Failure to observe this 
caution may result in an electric 
shock or fire hazard as well as 
damage to the unit.   

 

Do not install the product in a 
location where temperatures will 
exceed specification for the 
operator interface. Failure to 
observe this caution may result in 
abnormal operation or damage the 
product. 

 

Please note that this equipment 
has obtained EMC registration for 
commercial use. In the event that 
it has been mistakenly sold or 
purchased, please exchange it for 
equipment certified for home use. 

 

Do not use this product as an 
alarm device for disaster early 
warning systems nor as a system 
emergency stop as it may result in 
personal injury and equipment 
damage.

 

Wiring 

 

 

Connect the ground terminals to a 
class-3 ground (Ground resistance 
should not exceed 100Ω). 
Improper grounding may result in 
communication error, equipment 
damage, and electric shock or fire. 

 

 

Содержание HMIVU04CUNBE

Страница 1: ...tion Leaflet Instruction Leaflet IL04801003E Effective March 2013 Contents Description Page Preface 1 Safety Precautions 1 Installation 3 Wiring 4 Basic Inspection 4 Hardware Features 7 Panel Cut Out...

Страница 2: ...this quick start guide may be revised without notice Please consult an authorized distributor or download the most up to date version at www eaton com oi Safety Precautions Carefully note and observe...

Страница 3: ...rom the operator interface before wiring Insert only one wire into each terminal on the terminal block Communication Wiring Comply with communication wiring and grounding specifications for the networ...

Страница 4: ...nstalled waterproof gasket is present and properly aligned Step 2 Insert fasteners into the operator interface slots All should be finger tight initially Step 3 Torque all fasteners to 6 17lb inch 0 7...

Страница 5: ...s necessary as they may loosen due to vibration and varying temperatures Ensure that oil water metallic particles or any foreign objects do not fall inside the operator interface ventilation slots and...

Страница 6: ...MIVU07CUNBE COM1 Port Supports Flow Control PIN Contact RS 232 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 Note Blank No Connection COM2 and COM3 Port PIN MODE1 MODE2 MODE3 COM2 COM3 COM2 COM3 COM2 COM3 RS...

Страница 7: ...abled Note3 When COM2 port is used for RS 422 with flow control COM3 Port pins 1 4 6 and 9 are used for the signals RTS CTS RTS and CTS as shown in brackets COM3 Port PIN MODE1 MODE2 MODE3 RS 232 RS 4...

Страница 8: ...HMi VU Series Instruction Leaflet EATON CORPORATION www eaton com 7 Hardware Features HMIVU04CUNBE Front View A Power LED Indicator Lights in green when power is applied B Touch Screen Display B A...

Страница 9: ...ION www eaton com 8 HMIVU04CUNBE Rear View A USB Slave D Ethernet Port B USB Host E COM1 Note1 C System Button F Power Input Terminal N O T E 1 Refer to the Pin Definition for Communications section f...

Страница 10: ...HMi VU Series Instruction Leaflet EATON CORPORATION www eaton com 9 HMIVU06CUNB1 Front View A Power LED Indicator Lights in green when power is applied B Touch Screen Display A B...

Страница 11: ...ton com 10 HMIVU06CUNB 1 Rear View A Power Input Terminal E USB Host B COM2 and COM3 Note1 F USB Slave C COM1 G System Button D Battery Cover N O T E 1 Refer to the Pin Definition for Communications s...

Страница 12: ...HMi VU Series Instruction Leaflet EATON CORPORATION www eaton com 11 HMIVU07CUNBE Front View A Power LED Indicator Lights in green when power is applied B Touch Screen Display A B...

Страница 13: ...w A Power Input Terminal F USB Host B COM2 and COM3 Note1 G USB Slave C COM1 H System Button D Battery Cover I Ethernet Port E Memory Card Slot J Audio Output Port N O T E 1 Refer to the Pin Definitio...

Страница 14: ...is applied B Operation LED Indicator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one...

Страница 15: ...Power Input Terminal B COM3 Two LED indicate Read or Write status during the communication process C COM2 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Et...

Страница 16: ...is applied B Operation LED Indicator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when on...

Страница 17: ...put Terminal B COM2 Two LED indicate Read or Write status during the communication process C COM3 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet P...

Страница 18: ...ruction Leaflet EATON CORPORATION www eaton com 17 Panel Cut Out HMIVU04CUNBE HMIVU06CUNB1 6 79 172 4 7 24 184 5 67 144 0 063 1 6 0 24 6 5 21 132 4 HMIVU07CUNBE 7 24 184 5 67 144 5 21 132 4 6 79 172 4...

Страница 19: ...eries Instruction Leaflet EATON CORPORATION www eaton com 18 HMIVU08CUNBE 0 063 1 6 0 24 6 8 94 227 1 6 85 174 1 8 64 219 4 6 56 166 5 HMIVU10WCUNBE 10 71 272 7 88 200 0 063 1 6 0 24 6 10 29 261 3 7 4...

Страница 20: ...System Real Time OS MCU 32 bit RISC Micro controller NOR Flash ROM Flash ROM 128 MB OS System 30MB Backup 16MB User Application 82MB SDRAM 64Mbytes Backup Memory 16Mbytes Sound Effect Output Buzzer M...

Страница 21: ...tion Temp 0 o C 50 o C Storage Temp 20 o C 60 o C Ambient Humidity 10 90 RH 0 40 o C 10 55 RH 41 50 o C Pollution Degree 2 Vibration IEC 61131 2 compliant 5Hz f 8 3Hz Continuous 3 5mm 8 3Hz f 150Hz Co...

Страница 22: ...value of the power consumption indicates the electrical power consumed by HMi only without connecting to any peripheral devices In order to ensure the normal operation it is recommended to use a powe...

Страница 23: ...HMi VU Series Instruction Leaflet...