Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this 

product must be performed by a qualified electrician. This product must be installed in accordance 

with the applicable installation code by a person familiar with the construction and operation of the 

product and hazards involved. 

Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting 

any maintenance. Disconnect power at fuse or circuit breaker.

Risk of Fire- Refer to product label for specific minimum supply conductor requirements.

Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.

Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.

Failure to comply with these instructions may result in death, serious bodily injury and property damage.

WARNING

otee:

N

These instructions do not claim to cover all details or variations in the equipment, procedure, or process 

described, nor to provide directions for meeting every possible contingency during installation, operation 

or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for 

user’s purpose, please contact your nearest representative. 

otee:

N

Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area. 

otee:

N

Specifications and dimensions subject to change without notice. 

DISCLAIMER OF LIABILITYe: Eaton assumes no liability for damages or losses of any kind that may arise from the 

improper, careless, or negligent installation, handling or use of this product.

 

NOTICEe:

 Green ground wire provided in proper location. Do not relocate.

ATTENTION Receiving Departmente:

 Note actual fixture description of any shortage or noticeable damage on 

delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be 

filed within 15 days of delivery. All damaged material, complete with original packing must be retained.

Safety

: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and 

ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under 

installation section. 

APPLICATIONS

: This lighting fixture is designed for outdoor lighting services, and should not be used in area 

of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to 

installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation 

and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and 

maintained according to the following recommendations.

Содержание Galleon

Страница 1: ...fficiently for user s purpose please contact your nearest representative Note N Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area Note N Specifications and dimensions subject to change without notice DISCLAIMER OF LIABILITY Eaton assumes no liability for damages or losses of any kind that may arise from the improper careless or negligent ins...

Страница 2: ...thin the fixture to 40 ft lbs 54 N m A shallow 3 4 socket must be used in order to guarantee clearance of all drivers inside the fixture during this step 9 Attach the supply side ground wire to the ground terminal connector green wires 10 Connect the supply side line voltage wire to the fixture side line voltage terminal connector black wires 11 Connect the supply side neutral wire to the fixture ...

Страница 3: ...oosen 3 screws located in the access door of the fixture and open the door 2 Pull all supply wires through the mast arm mast arm adapter and into the center grommet located between the mounting bolts at the back of the fixture 3 Install the 1st mounting bolt 1 2 13 x 1 1 4 and lockwasher through the top side hole at the back of the fixture and into the mast arm adapter 4 Install the 2nd mounting b...

Страница 4: ...electric control or shorting cap into receptacle and twist into locked position Note N The photocontrol not included must contain a soft resilient gasket fastened to the bottom surface to assure a proper weather seal between the control and the receptacle Bi Level Switching If Equipped For Bi level switching the input leads to the fixture will be independently labeled to indicate dimming preferenc...

Страница 5: ... conforme au Code national de l électricité aux lois et ordonnances locales en vigueur Une mise à la terre adéquate est requise afin d assurer votre sécurité Respectez soigneusement la procédure de mise à la terre du chapitre d installation APPLICATIONS ce luminaire a été conçu pour l éclairage extérieur et ne doit pas être utilisé dans un endroit peu ventilé ou dans des enceintes à haute températ...

Страница 6: ...ns le luminaire selon un couple de 54 N m Pour cela vous devrez utiliser une douille courte de 1 9 cm afin de garantir un dégagement suffisant pour tous les circuits intérieurs du luminaire 10 Raccordez le fil de terre provenant de l alimentation à la borne de terre fils verts 11 Raccordez le fil de tension provenant de l alimentation à la borne de tension du luminaire fils noirs 12 Raccordez le f...

Страница 7: ...sse ou l adaptateur pour crosse puis dans le passe câble central situé entre les boulons de montage à l arrière du luminaire 3 Passez le 1er boulon de montage 1 2 po 13 x 1 1 4 po avec une rondelle frein à travers l orifice situé dans le coin supérieur à l arrière du luminaire puis dans l adaptateur pour crosse 4 Passez le 2e boulon de montage 1 2 po 13 x 1 1 4 po avec une rondelle frein à travers...

Страница 8: ... photo électrique ou fiche de mise en court circuit dans le réceptacle et tournez le pour le verrouiller en place Remarque Un joint souple et résistant doit être posé sous l interrupteur photoélectrique non inclus pour assurer l étanchéité entre ce dernier et la prise Commutation À Deux Niveaux D intensité Si Fournie En cas de commutation à deux niveaux d intensité chaque fil d alimentation du lum...

Страница 9: ...ables Se requiere una conexión a tierra adecuada para garantizar la seguridad personal Observe cuidadosamente el procedimiento de conexión a tierra en la sección de instalación APLICACIONES Este accesorio de iluminación está diseñado para servicios de iluminación al aire libre y no debe utilizarse en áreas de ventilación limitada o en lugares cerrados a alta temperatura ambiente Debe almacenarse e...

Страница 10: ...rese de que el perno está completamente enroscado a través de la placa de las tuercas 9 Ajuste ambas tuercas dentro del accesorio a 40 pies lbs Se debe utilizar un enchufe poco profundo de 3 4 para garantizar el espacio libre para todos los controladores dentro del accesorio durante este paso 10 Adjunte el cable a tierra del lado del suministro al conector terminal a tierra cables verdes 11 Conect...

Страница 11: ...ale de los cables del suministro a través del brazo mástil o del adaptador del brazo del mástil y dentro de la arandela aislante central situada entre los pernos de montaje en la parte trasera del accesorio 3 Instale el primer perno de montaje 1 2 13 x 1 1 4 y la arandela de presión a través del orificio lateral superior en la parte trasera del accesorio y en el adaptador del brazo del mástil 4 In...

Страница 12: ...táculo hasta que la flecha indicadora apunte al norte 3 Vuelva a ajustar los tornillos 4 Inserte el control fotoeléctrico o la tapa de cortocircuito en el receptáculo y gírelo hacia la posición de bloqueo Nota N El fotocontrol no incluido debe contener una junta suave y flexible sujetada a la parte inferior de la superficie para garantizar un sellado adecuado contra el clima entre el control y el ...

Страница 13: ...nergy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off an on the user is encouraged to try to correc...

Отзывы: