Eaton ePDU Скачать руководство пользователя страница 26

Warranty

Eaton Advanced ePDU Troubleshooting Guide    P-164000140—Rev 1    

www.eaton.com/ePDU

21

Customer Service Engineer or Agent; (e) improper testing, operation, maintenance, adjustment or modification 
of any kind not authorized in writing by Company personnel or performed by an authorized Company Customer 
Service Engineer or Agent; or (f) use of the Product under other than normal operating conditions or in a manner 
inconsistent with the Product’s labels or instructions.

This Warranty is not valid if the Product’s serial numbers have been removed or are illegible. Any Warranted 
Items repaired or replaced pursuant to this Warranty will be warranted for the remaining portion of the original 
Warranty subject to all the terms thereof.

Company shall not be responsible for any charges for testing, checking, removal or installation of Warranted 
Items.

COMPANY DOES NOT WARRANT EQUIPMENT NOT MANUFACTURED BY COMPANY. IF PERMITTED BY 
THE APPLICABLE MANUFACTURER, COMPANY SHALL PASS THROUGH SUCH MANUFACTURER’S 
WARRANTIES TO END-USER.

COMPANY DOES NOT WARRANT SOFTWARE (IF APPLICABLE TO THE PRODUCT), INCLUDING 
SOFTWARE EMBEDDED IN PRODUCTS, THAT IS NOT CREATED BY COMPANY. WITHOUT LIMITING THE 
FOREGOING, COMPANY SPECIFICALLY DOES NOT WARRANT SOFTWARE (SUCH AS LINUX) THAT WAS 
CREATED USING AN “OPEN SOURCE” MODEL OR IS DISTRIBUTED PURSUANT TO AN OPEN SOURCE 
LICENSE.

THIS WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY OFFERED BY COMPANY WITH RESPECT TO 
THE PRODUCTS AND SERVICES AND, EXCEPT FOR SUCH FOREGOING WARRANTY COMPANY 
DISCLAIMS ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF 
MERCHANTABILITY, TITLE, NON-INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. 
CORRECTION OF NONCONFORMITIES IN THE MANNER AND FOR THE PERIOD OF TIME PROVIDED 
ABOVE SHALL CONSTITUTE COMPANY’S SOLE LIABILITY AND ENDUSER’S EXCLUSIVE REMEDY FOR 
FAILURE OF COMPANY TO MEET ITS WARRANTY OBLIGATIONS, WHETHER CLAIMS OF THE END-USER 
ARE BASED IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY), OR OTHERWISE.

LIMITATION OF LIABILITY: The remedies of the End-user set forth herein are exclusive and are the sole 
remedies for any failure of Company to comply with its obligations hereunder. In no event shall Company be 
liable in contract, in tort (including negligence or strict liability) or otherwise for damage to property or 
equipment other than the Products, including loss of profits or revenue, loss of use of Products, loss of data, 
cost of capital, claims of customers of the End-user or any special, indirect, incidental or consequential 
damages whatsoever. The total cumulative liability of Company hereunder whether the claims are based in 
contract (including indemnity), in tort (including negligence or strict liability) or otherwise, shall not exceed the 
price of the Product on which such liability is based.

Company shall not be responsible for failure to provide service or parts due to causes beyond Company's 
reasonable control.

END-USER'S OBLIGATIONS: In order to receive the benefits of this Warranty, the End-user must use the 
Product in a normal way; follow the Product’s user’s guide; and protect against further damage to the Product 
if there is a covered defect.

OTHER LIMITATIONS: Company’s obligations under this Warranty are expressly conditioned upon receipt by 
Company of all payments due to it (including interest charges, if any). During such time as Company has not 
received payment of any amount due to it for the Product, in accordance with the contract terms under which 
the Product is sold, Company shall have no obligation under this Warranty. Also during such time, the period of 
this Warranty shall continue to run and the expiration of this Warranty shall not be extended upon payment of 
any overdue or unpaid amounts.

Содержание ePDU

Страница 1: ...Eaton Advanced Enclosure Power Distribution Unit ePDU Troubleshooting Guide ...

Страница 2: ...and Windows are registered trademarks of Microsoft Corporation in the United States and other countries Mozilla and Firefox are registered trademarks of the Mozilla Foundation All other trademarks are property of their respective companies Copyright 2012 Eaton Corporation Raleigh NC USA All rights reserved No part of this document may be reproduced in any way without the express written approval o...

Страница 3: ...unications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense ICES 003 This Class A Interference Causing Equipment meets all requirements of the Canadian Interference Causing Equipment Regulations ICES 003 Cet appareil numérique de la classe A respecte toutes les exigences ...

Страница 4: ...e risk of electric shock symbol CAUTION REFER TO OPERATOR S MANUAL Refer to your operator s manual for additional information such as important operating and maintenance instructions This symbol indicates that you should not discard waste electrical or electronic equipment WEEE in the trash For proper disposal contact your local recycling reuse or hazardous waste center ...

Страница 5: ...r E mail Notifications with History Reports 3 Resolving Problems 4 Clearing Alarm Notifications 4 Clearing the Web Interface Event Log 4 Clearing the LCD Panel Event Log 4 Suppressing ePDU Alarm Indicators 4 Contacting Service and Support 5 2 TROUBLESHOOTING 6 Power Outlets 6 Chassis and Installation 7 Circuit Breakers 7 LCD Operation 8 COM Ports 9 ePDU Web Interface Alarms and Events 11 Error Mes...

Страница 6: ...er Outlet LEDs on the ePDU Power outlets are arranged in groups called factory groups and are color coded on each ePDU model LEDs for each factory group are located on the top surface of the ePDU see Figure 1 The display mode of a status LED indicates the current ePDU operating status l LED is illuminated On when an outlet is powered l LED is Off if an outlet is unpowered l LED flashes On and Off ...

Страница 7: ...provide correct information or retry an operation LCD Panel The ePDU has a three button graphical LCD panel The LCD panel is located on the top surface of the ePDU see Figure 2 You can use this interface to retrieve current ePDU alarm data or to change ePDU operation settings to resolve certain ePDU problems Alarms can also display automatically For example the display can show active alarms as th...

Страница 8: ...the ePDU Outlets page to obtain information on individual outlets or factory groups You can also use this page to set individual outlets or factory groups to On Off or Reboot Use the Active Alarms page to retrieve current alarms and see a list of alarms by date time and description l Logs and Notifications Use the Logs Notifications menu selections to see a list of the most recent events or clear ...

Страница 9: ...at may help you solve problems If you cannot find a resolution to a problem in the tables contact customer service or a local representative for guidance or product part replacement Clearing Alarm Notifications The are several ways to clear alarm notifications For example you can clear accumulated events from the Event Log display on ePDU interfaces or suppress blinking alarm indicators on the ePD...

Страница 10: ... following information ready when you call for service l Model number l Serial number l Date of failure or problem l Symptoms of failure or problem l Customer return address and contact information Table 1 provides the Eaton catalog part number for ordering optional and spare parts for the ePDU Contact your local service representative for more information Table 1 Optional and Spare Parts Eaton Ca...

Страница 11: ...f restart the ePDU and then reconnect the device to ePDU 5 Check the Media Access Control MAC address on the device and in the Web pages Outlet LED is On but there is no power to outlet l Circuit breaker CB has tripped l Internal issue outlet relay is open 1 Check the CB state on the ePDU NOTE In a normal situation the LED should be Off with a tripped CB for Managed MA and Advanced Monitored AM eP...

Страница 12: ...lastic clip feet with keyhole button system Difficulty aligning the keyhole buttons with the rack keyholes l Clip feet and keyhole buttons were incorrectly pre assembled on the ePDU before rack installation 1 First try to assemble the clip feet and keyhole buttons Then place the two subassemblies in the rack keyholes Finally clip the ePDU inside the installed clip feet You should hear a clicking s...

Страница 13: ...f the ePDU for 3 seconds The screen saver should restart Alarm does not display on the LCD even though condition exists l Settings are not kept in ePDU memory after a power cycle On Off if the value is outside a specific range see Table 6 l LCD internal failure 1 Check the settings again They may have to be reset within the range specified in Table 6 LCD is frozen and buttons are not working Firmw...

Страница 14: ...t critical I setting 100 I rating OUTLET Low voltage warning 70 V rating V setting 95 V rating OUTLET Over voltage warning 105 V rating V setting 130 V rating OUTLET Over voltage critical 105 V rating V setting 130 Voltage rating OUTLET Over current warning I setting 100 I rating OUTLET Over current critical I setting 100 I rating NOTE The I rating for C13 outlets is 10A The I rating for C19 outle...

Страница 15: ...rmal protocols 2 Restart the Network Management Card by pushing the recessed reset button and waiting 40 seconds for the connection to be re established NOTE Attention This will power off the loads 3 Restart the ePDU by unplugging the mains and waiting 40 seconds after power has been re established NOTE Attention This will power off the loads 4 Try uploading the Network Management Card firmware us...

Страница 16: ... 1 is in an alarm state open or closed The user can define the alarm state open or closed from the Web interface 1 Check the equipment connected to the Environment Monitoring Probe EMP dry contact Environment Dry Contact 1 normal This event is logged when the dry contact 1 returns to a normal state open or closed The user can define the alarm state open or closed from the Web interface No action r...

Страница 17: ...alue No action required Environment probe connected This event is logged when the Network Management Card detects the connection of the environment sensor No action required Environment probe disconnected This event is logged when the Network Management Card detects the withdrawal of the environment sensor No action required Environment sensor communication failure This alarm appears when the comm...

Страница 18: ...t cable No action required Network Management Card cannot initiate communication with the ePDU core This event is logged when the Network Management Card is unable to read the ePDU data As a result the data displayed in the Web interface are erroneous 1 Restart the Network Management Card by pushing the recessed reset button and waiting 40 seconds for the connection to be re established 2 Restart ...

Страница 19: ...Outlet iNAME low voltage warning This alarm appears when the voltage on outlet iNAME is below the outlet iNAME low voltage warning threshold The user can define the low voltage warning threshold for each outlet from the Web interface 1 Check the load of the outlet iNAME or factory group iNAME Outlet iNAME voltage normal This event is logged when the outlet iNAME voltage returns to a normal value 1...

Страница 20: ...e ePDU input voltage PDU L i high voltage warning This alarm appears when the voltage on phase i is higher than the phase i high voltage warning threshold The user can define the high voltage warning threshold for each phase from the Web interface 1 Check the ePDU input voltage PDU L i low voltage warning This alarm appears when the voltage on phase i is below the phase i low voltage warning thres...

Страница 21: ...e phase ePDU 1 2 3 for 3 phase ePDU Interface The interface in which the user has logged in Valid values are HTTP Telnet Serial Recipient Recipient of the e mail E mail account to which the test e mail has been sent Date Time Logged date and time The new date and time defined by the user Queue Name The name of the message queue that ran out of its capacity Valid values are QUEUE_EMAIL QUEUE_TRAP Q...

Страница 22: ...k Management Card configuration file l 6 Kbytes for the ePDU configuration file Failed to send a request to the Network Management Card Retry later Configuration request failed 1 Try to upload the configuration file again for the operation that just failed 2 Confirm that you can ping the Network Management Card 3 If the issue persists check the following l ePDU installation and Ethernet cable l IP...

Страница 23: ...ton and waiting 40 seconds for the connection to be re established Verify that temperature and or humidity information displays on the Web interface NOTE Attention This will power off the loads Cable retention tray P N KBLT01 Mounting is impossible l Tray does not fit or does not appear to be designed to fit the ePDU configuration l Tray is defective 1 Only use P N KBLT01 Visit www eaton com ePDU ...

Страница 24: ...y with grounded outlets at both the computer and monitor When using a backup UPS power the computer monitor and appliance off the supply l The installation power outlet used for the power supply to this equipment must be installed near the equipment and must be easily accessible l When installing this product it is essential that the distribution circuit supplying the product is protected by a bra...

Страница 25: ...he End user supplies a credit card number or purchase order for the value of the replacement Product Company will use commercially reasonable business efforts to ship via standard ground shipment and at no cost to the End user the replacement Warranted Item to the End user within one 1 business day after Company receives notice of the warranty claim In such case the End user must return at Company...

Страница 26: ...CONSTITUTE COMPANY S SOLE LIABILITY AND ENDUSER S EXCLUSIVE REMEDY FOR FAILURE OF COMPANY TO MEET ITS WARRANTY OBLIGATIONS WHETHER CLAIMS OF THE END USER ARE BASED IN CONTRACT IN TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR OTHERWISE LIMITATION OF LIABILITY The remedies of the End user set forth herein are exclusive and are the sole remedies for any failure of Company to comply with its obliga...

Страница 27: ...or replacement equipment installation materials freight charges travel expenses or labor of Company representatives outside the terms of this Warranty will be borne by the End user OBTAINING WARRANTY SERVICE In the USA call the Customer Reliability Center 7x24 at 800 356 5737 Outside of the USA contact your local Eaton product sales or service representative or call the Customer Reliability Center...

Отзывы: