dd) Fit the speedo sensor assembly; tighten to 24 – 30 N m.
ee) During transmission overhauling, inspect the magnet (1) for any wear / dislocation.
If any wear / dislocation observed, replace magnet with
new one. To fit new magnet, follow the procedure as
below:
Place the case on the table
Apply loctite 7649 where magnet to be installed. Note –
This is a primer to clean the surface.
Apply Loctite 7649(Resin), 326(Glue) & Install the
magnet, press magnet for 15 seconds.
Fit the elbow adaptor (2).
ff) Ensure that the mating faces of the pump and case halves are clean. DO NOT use sealant. Fit the
oil pump ensuring that the flats on the oil pump rotor engage the flats on the countershaft end. Refit
the oil strainer/drain plug. Tighten the screws securely.
Содержание EEV-7202