manualshive.com logo in svg
background image

3

3. Features

Eaton Arc Flash Relay System

   MN026010EN   March 2016   www.eaton.com

Figure 2.  Double Ended Substation with Selective Feeder Trip Using Point Sensors.

Figure 3.  Double Ended Substation Using Fiber Loop Sensors.

CB

EAFR-110P

EAFR-110P

ERROR

POWER

SET

T1
T2

S1

IL1

S2

IL2

S3

IL3

S4

Ig

S5
BI1
BI2

HSO1

BO1

HSO2

T3
T4

Eaton Arc Flash Relay

EAFR-110P

EAFR-110P

ERROR

POWER

SET

T1
T2

S1

IL1

S2

IL2

S3

IL3

S4

Ig

S5
BI1
BI2

HSO1

BO1

HSO2

T3
T4

Eaton Arc Flash Relay

EAFR-101

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

EAFR-101

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

EAFR-101

EAFR-101

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

EAFR-101

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

EAFR-101

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

CS:2A

CS:1

CS:1

CS:1

CS:1

CS:1

CS:1

CS:2A

 

EAFR-110F

EAFR-101F

EAFR-101F

EAFR-110F

Trip + CBFP

Trip + CBFP

HSO1 / T1

Trip + CBFP

HSO1 / T1

S1

S1

S2

S3

S2

S3

T3

T1
T2

Trip + CBFP

Trip + CBFP

Trip + CBFP

Current

Current

Light

CB

CB

1A

CB

4A-3

CB

4A-2

CB

4A-1

CB

3AB

CB

4B-1

CB

4B-2

CB

4B-3

CB

1B

CB

1A

1B

EAFR-110F

ERROR

POWER

SET

T1
T2

S1

IL1

S2

IL2

S3

IL3

Io

QD
BI1
BI2

HSO1

BO1

HSO2

T3
T4

Eaton Arc Flash Relay

EAFR-110F

ERROR

POWER

SET

T1
T2

S1

IL1

S2

IL2

S3

IL3

Io

QD
BI1
BI2

HSO1

BO1

HSO2

T3
T4

Eaton Arc Flash Relay

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

EAFR-101

ERROR

T1,T3,T4
T2,T4

POWER

SET

S1
S2
S3
S4
S5
BI1
BI2
BO1

Eaton Arc Flash Relay

Light

Legend:

CBFP - Circuit Breaker Failure Protection
HSO - High Speed Output
T - Trip Output
MT - Multi trip

Содержание EAFR-110F

Страница 1: ...Eaton Arc Flash Relay System EAFR 110F EAFR 101 MN026010EN...

Страница 2: ...ICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUME...

Страница 3: ...eaker Failure 2 3 8 Communications 2 4 EATON ARC FLASH RELAY MODULES 5 5 DIMENSIONS 6 6 EATON ARC FLASH RELAY SENSORS 8 7 TECHNICAL DATA 9 7 1 Protection Stages 9 7 2 Current Measuring Circuits 9 7 3...

Страница 4: ...iv MN026010EN Eaton Arc Flash Relay System MN026010EN March 2016 www eaton com...

Страница 5: ...egrated dual trip criteria It is designed to minimize the damage caused by an arcing fault arc flash by tripping the circuit breaker sourcing the fault current Three phase instantaneous overcurrent el...

Страница 6: ...er the set time delay 3 8 Communications Because of the simplicity of the system all monitoring is done through contact outputs on the modules The advan tage of this approach is that cybersecurity iss...

Страница 7: ...Eaton Arc Flash Relay EAFR 101 EAFR 101 ERROR T1 T3 T4 T2 T4 POWER SET S1 S2 S3 S4 S5 BI1 BI2 BO1 Eaton Arc Flash Relay EAFR 101 EAFR 101 ERROR T1 T3 T4 T2 T4 POWER SET S1 S2 S3 S4 S5 BI1 BI2 BO1 Eato...

Страница 8: ...010EN March 2016 www eaton com Figure 4 Single Ended Substation Using Fiber Loop Sensors and External Current Input A T1 T2 S2 BI 1 CB CB CB S1 S3 E Series CB CB EAFR 102 ERROR T1 T3 T4 T2 T4 POWER SE...

Страница 9: ...Modules Features EAFR 110F EAFR 110P EAFR 102 EAFR 101 D 3 Phase Current Detection Yes Yes No No Ground Current Detection Yes Yes No No Maximum Point Sensors 0 12 0 12 Maximum Fiber Loop Sensors 3 0...

Страница 10: ...IP 1 TRIP 2 SEN 1 SEN 2 SEN 3 SEN 4 FIBER I IN L OUT M TRIP L1 L2 L3 Io BO1 BO2 ARC PROTECTION SET AQ 1 10 157 6 18 82 3 23 164 6 46 102 4 01 EAFR 110P ERROR POWER SET T1 T2 S1 IL1 S2 IL2 S3 IL3 S4 Ig...

Страница 11: ...ns in Millimeters inches Side View Figure 11 EAFR 101D Dimensions in Millimeters inches Side View 175 6 89 157 6 18 160 6 30 10 0 39 17 0 67 48 5 1 91 10 0 39 110 4 33 145 5 71 21 5 0 85 108 4 25 34 1...

Страница 12: ...026010EN March 2016 www eaton com 6 Eaton Arc Flash Relay Sensors Figure 13 EAFR 06 Arc Light Plastic Fiber Sensor Figure 14 EAFR 07 Arc Light Glass Fiber Sensor Figure 15 EAFR 01 A Point Sensor Figur...

Страница 13: ...Carry 2 A Make and Carry for 0 5 s 15 A Make and Carry for 3s 6 A Breaking Capacity DC When Time Constant L R 40 ms 1 A 110 W Contact Material Semiconductor 7 5 Binary Output BO1 Rated Voltage 24 Vdc...

Страница 14: ...package 7 11 Environmental Conditions Specified Ambient Service Temp Range 35 to 70 C 31 to 158 F Transport and Storage Temp Range 40 to 70 C 40 to 158 F Relative Humidity Up to 97 7 12 Approvals UL...

Страница 15: ...glass fiber sensor 20 m 65 62 ft EAFR 07 25 65C2014G04 Arc light glass fiber sensor 25 m 82 02 ft EAFR 07 30 65C2014G05 Arc light glass fiber sensor 30 m 93 43 ft EAFR 07 35 65C2014G06 Arc light glas...

Страница 16: ...rd Cleveland OH 44122 United States Eaton com 2016 Eaton All Rights Reserved Printed in USA Publication No MN026010EN TBG1274 March 2016 Eaton is a registered trademark All trademarks are property of...

Отзывы: