P/N 01-00510-00 

7500 Series Specifications 

Dimensions (overall)  

Height  

6.31”  (160 mm) 

Width 10.51” 

(267 

mm) 

Depth 5.25” 

(133 

mm) 

 

Weight 

• 

7 lbs (3.18 Kg)  

 

Voltage 

• 

24 VDC, -15% / +20% 

 

Power Consumption 

• 

16 Watts (without optional communication 
interface board) 

• 

22 Watts (with optional communication interface 
board) 

 

Heat Output 

• 

16 Watts (55 BTU/Hour) (without optional 
communication interface board) 

• 

22 Watts (75 BTU/Hour) (with optional 
communication interface board) 

 

Current 

• 

0.8 A (without optional communication interface 
board) 

• 

1.1 A (with optional communication interface 
board) 

 

Peak Inrush Current 

• 

16 A 

 

System Ambient Temperature 

• 

Operating:  0 - 50° C (32 - 122° F) 

• 

Non-operating:  -20 - 60° C (-4 - 140° F) 

 

System Vibration 

• 

Operating:  1 G at 10 - 500 Hz 

• 

Non-operating:  1 G at 10 - 500 Hz

 

 

System Shock 

• 

Operating:  30 G 

• 

Non-operating:  30 G

 

 

Relative Humidity 

• 

Operating:  20 - 90% non-condensing 

• 

Non-operating:  20 - 90% non-condensing 

 

Altitude 

• 

Operating:  10,000 ft (3,048 m) above sea level 

• 

Non-operating:  40,000 ft (12,192 m) above sea 
level 

 

Emissions 

• 

CISPR 22 Class A-Radiated and Conducted 

 

Noise Immunity 

• 

IEC 801-2,3,4,6,8 

• 

IEC 61000-4-2,3,4,5,6,8

 

 

Agency Certifications 

• 

CE Mark 

• 

UL/cUL and CSA Class I, Division 2, Groups A, 
B, C, D certified

 

 

Содержание Cutler-Hammer PanelMate ePro 7500 Series

Страница 1: ...PanelMate ePro 7500 Series ...

Страница 2: ...ANT DOWN ONLY 800 809 2772 selection 5 5PM 8AM EST 414 449 7100 selection 5 5PM 8AM EST EMAIL CHATechSupport eaton com If you are in the US or Canada and have OI PLC IPC questions you can take advantage of our toll free line for technical assistance with hardware and software product selection system design and installation and system debugging and diagnostics Technical support engineers are avail...

Страница 3: ...itions will severely shorten the unit s life Refer to Eaton s Cutler Hammer PanelMate ePro Users Guide for panel sizing and cabling recommendations The guide is available on the Cutler Hammer website www cutler hammer eaton com Mounting dimensions are shown on the Mounting Diagram page of this document The Mounting dimensions also available on the Cutler Hammer website Safety Considerations This e...

Страница 4: ...Catalog Number 1219B is available for converting 120 230VAC to 24VDC CAUTION Your PanelMate ePro unit could be severely damaged if it is connected to voltages outside the range of 18 to 30VDC While your PanelMate ePro unit is fully protected against polarity reversal damage can occur if the unit is not wired correctly GND GND CAUTION If you are converting from a PanelMate powered from a 24VDC powe...

Страница 5: ...on 2 environment then the external power supply must be appropriately rated Use single point grounding The external power supply and the PanelMate should be grounded to the same point This should be practiced even when the devices are located in separate enclosures This will help prevent ground loop issues Install a power supply solely for the PanelMate If the present external power supply is used...

Страница 6: ...terface cards in your PanelMate ePro unit complete the following steps 1 Disconnect power from your PanelMate ePro unit 2 Use a Phillips screwdriver to unscrew the six screws located on the back of your PanelMate ePro unit and remove the back cover 3 Use a Phillips screwdriver to remove the screw that secures the slot cover and remove the slot cover 4 Place the interface card in the slot and secur...

Страница 7: ... PanelMate ePro unit comes pre loaded with the M Systems DiskonKey USB driver Simply plug a DiskonKey device into the USB port of your PanelMate ePro unit and wait for the LED to stop flashing Use Explorer to find the files on the device which is listed as Removable Disk Z Note that the Iomega USB driver is also pre loaded on the ePro but it is disabled See the PanelMate ePro Users Guide for instr...

Страница 8: ...Mounting Diagram Notes Dimensions are in inches Allow cable clearance on both left and right side of unit The mounting diagram is available in dwg format on Eaton s Cutler Hammer website ...

Страница 9: ... interface board 1 1 A with optional communication interface board Peak Inrush Current 16 A System Ambient Temperature Operating 0 50 C 32 122 F Non operating 20 60 C 4 140 F System Vibration Operating 1 G at 10 500 Hz Non operating 1 G at 10 500 Hz System Shock Operating 30 G Non operating 30 G Relative Humidity Operating 20 90 non condensing Non operating 20 90 non condensing Altitude Operating ...

Отзывы: