EATON Airflex WSB 11210 WCSB3 Installation Operation and Maintenance E-CLCL-11001-E October 2013
13
Caution
High inlet pressures or surges exceeding the maxi
mum allowable may result in damage to the
tensioner.
2.4.6 The coolant supply and discharge hose, pipe and
fitting sizes, along with minimum flow rates for the
tensioner rated horsepower, are listed in Table 8.
2.4.7 Coolant supply connections to the tensioner should
provide a parallel flow through each section of the
tensioner.
Warning
Series flow is not recommended as it can lead to
overheating of the tensioner.
2.4.8 Inlet and outlet coolant manifolds must be provided
by the customer. Manifolds should be constructed
to allow for even flow through all ports. Hoses can
be routed to the pressure plate (116), reaction plates
(30) and end plate (117) to assist with balancing the
pressure drop.
2.4.9 Inlet and outlet coolant manifolds and hoses must be
sized to handle the maximum flow for each size
tensioner per Table 8.
Caution
Do not plug any ports or plumb the cooling passages
in series. Parallel arrangement of hoses similar to that
shown in Figure 5 is required for proper coolant flow.
2.4.10 The number of flexible hoses required for both the
inlet and outlet ports of each size tensioner is given in
Table 9.
Table 7
Coolant Pressure, psi (bar)
Size
Maximum Static
Maximum Inlet*
436WCSB3
40 (2,7)
40 (2,7)
* Under Dynamic flow Conditions
Note: Above ratings are for tensioning/winding type applications. For high
cyclic application, consult the factory.
WCSB3 Brakes
Table 8
36WCSB3 Coolant Supply Data
Min Flow Rate
Number
GPM (dm
3
/min)
of Water
Thermal
Min Flow Rate 50% Water, 50%
Cooled Disc Rating
Water Inlet and
GPM (dm
3
/min) Ethylene Glycol
Discs
Size HP (kW)
outlet Pipe Size 100% Water
by Vol
3
36
3000 (2237) SAE-20 J1926 ORB 300 (1135)
354(1340)
INLET
MANIFOLD
'LEFT'
OUTLET
MANIFOLD
'BOTTOM'
Motor
Pump
Strainer
Pressure
Switch
Strainer
Heat Ex
changer
Temperature
Switch
Pressure
Relief
Valve
Temperature
Sensor
Bulb
Modulating Valve
Level Switch
OUTLET
MANIFOLD
'TOP'
INLET
MANIFOLD
'RIGHT'
WCSB
436WCSB3
FLOW CONTROL
(if required)