UPS UPS works in battery mode, and the buzzer beep for 4 seconds to
remind that the battery is discharged. To cancel the alarm, see 7.3.4
Setting
→
General
•
Since there is no utility power input, the input abnormal alarm will be
displayed on the LCD.
7.4.2 UPS Shutdown
Shutdown the UPS with utility power mode:
•
UPS working with utility power, press the button for more than 3s, the
LCD pops up to confirm the shutdown page;
•
After clicking Confirm, the UPS performs shutdown;
•
After shutdown, the UPS works in bypass mode and the output remains
powered;
•
If there is no need the UPS output, disconnect the input utility power.
Shutdown the UPS with battery mode:
•
Press the button for more than 3s, the LCD pops up to confirm the
shutdown page;
•
After clicking Confirm, the UPS performs shutdown;
•
The UPS output is interrupted and goes into standby mode. After a few
seconds, the UPS automatically shuts down.
7.4.3 UPS function
•
Working mode
Mode
Break time
Output frequency
PF correction
Line mode
0ms
Follow the input within
the allowed range
Yes
High efficient mode
10ms
Fully follow the input
No
ESS
efficient mode
2ms
Fully follow the input
No
CVCF mode
0ms
Fixed 50Hz/60Hz
Yes
•
Automatically restart/Restart battery
After the battery is exhausted, when the utility power is restored, the UPS will
enter the bypass mode and charge the battery. When the user setting turns on
the automatic restart function, and the battery reaches the set restart battery
power, The UPS will automatically restart.
Содержание 9SX 15KPMAU Series
Страница 1: ...Eaton 9SX 15 20KPM CH 系列 在线式 UPS ...
Страница 2: ......
Страница 10: ...4 2 2 电池箱 电池箱 电池箱 电池箱 EBM 前视图 后视图 功能说明 1 保险丝盒 2 电池连接口 1 3 电池连接口 2 4 RJ45 接口 电池侦测模块 5 外部接地螺丝 ...
Страница 60: ...54 附录一 附录一 附录一 附录一 系统框图 系统框图 系统框图 系统框图 ...
Страница 62: ...56 附录 附录 附录 附录三 三 三 三 有害物质表 有害物质表 有害物质表 有害物质表 ...
Страница 63: ...Eaton 9SX 15 20KPM AU Series Online UPS Eaton DXRT15 20KS IN Series Online UPS ...
Страница 64: ...Copyright 2019 EATON All rights reserved ...
Страница 126: ...120 Storage temperature without battery 25 60 Criterion Safety EN62040 1 2008 A1 2013 EMC EN 62040 2 ...
Страница 127: ......
Страница 128: ...121 614 40045 00 ...