EMC Statements 

FCC Part 15 

NOTICE: 

Pursuant to section 15 of the FCC rules, this product has been tested and thereby 

complies to the conditions of a Class B (700-1500VA) and Class A (2000-3000VA) digital 
device, which have been established for offering sufficient protection against dangerous 
interference for installation in a residential area. Installation and use of the equipment should 
comply with the instructions provided in order to avoid such interference due to the amount 
of radio frequency energy that is radiated and generated by the equipment. In spite of this, 
we cannot assure that a certain amount of interference may not occur in some installations. If, 
by turning on and off, it can be deduced that your radio or television reception is found to be 
influenced by harmful interference from the equipment, it is recommended to use one of the 
following preventive measures: 

z

 

Place the receiving antenna in a separate location or orientation. 

z

 

Ensure a greater distance is achieved between the receiver and the equipment. 

z

 

Ensure that your equipment is connected to an outlet on a separate circuit than the 
receiver. 

z

 

Contact a technician experienced with radio and TV or a dealer for further assistance. 

ICES-003 

This Class B Interference Causing Equipment meets all requirements of the Canadian 
Interference Causing Equipment Regulations ICES–003. Cet appareil numérique de la classe 
B respecte toutes les exigences du Reglement sur le matériel brouilleur du Canada. 

Declaration of Conformity Request 

Units labeled with a CE mark comply with the following standards and directives: 

z

 

Harmonic Standards: EN 50091-1-1 and EN 50091-2 

z

 

EU Directives:73/23/EEC, Council Directive on equipment designed for use within 
certain voltage limits 

93/68/EEC, Amending Directive 73/23/EEC 

89/336/EEC, Council Directive relating to electromagnetic compatibility 

92/31/EEC, Amending Directive 89/336/EEC relating to EMC 

The EC Declaration of Conformity is available upon request for products with a CE 

mark. 

Содержание 700VA

Страница 1: ...easures z Place the receiving antenna in a separate location or orientation z Ensure a greater distance is achieved between the receiver and the equipment z Ensure that your equipment is connected to...

Страница 2: ...isk of electric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is...

Страница 3: ...ly detailed requirements of the UPS units are described herein and installation must be carried out in accordance with this manual Electrical installations must also carefully follow local legislation...

Страница 4: ...eports any problems on the LCD display An advanced battery management system always monitors the conditions of the batteries sends any forewarnings if replacement is needed Otherwise every 30 days of...

Страница 5: ...operations are to be performed exactly as instructed in this manual The greatest care possible must be taken for any of these operations and any change thereof may prove very hazardous to the operato...

Страница 6: ...he following illustration Vertical Installation Wall mounted installation 7 Installation with accessories of Rack mounted types Please install the types of units according to the following illustratio...

Страница 7: ...8 Installation with accessories of Stack types Please install the types of units according to the following illustration Stack installation 9 5 2 Rear panel views 700 1 5KVA REAR PANEL...

Страница 8: ...10 2K 3KVA REAR PANEL 11 RM 1U 700 1KVA Rear Panel...

Страница 9: ...12 RM 2U 700 1K 1 5KVA Rear Panel 13 RM 2U 2K 3KVA Rear Panel...

Страница 10: ...instantly shows a Site Wiring Fault rotate the connector Schuko see chapter 7 4 z After charging connect the loads to the UPS see the example in fig 3 z Do not connect any devices that have the possi...

Страница 11: ...ctions 2 TxD Output TxD Output 3 RxD Input RxD Inverter Off Input 5 Common Common 6 Output Ac Fail Output 8 Output Low Battery Output 9 Output 12 VDC Power Caution Max rated values 12Vdc 17 USB port o...

Страница 12: ...off the UPS 2 is a Enter button Use this button to check content of UPS and the method is listed below a Push the button at least 2 seconds to check content of UPS Each content can be displayed by pr...

Страница 13: ...URE xxC Shows approximate ambient temperature BAT PACK NUM x Shows External Battery Pack Number RATING xxxxVA Shows UPS Rating CPU VERSION xx x Shows CPU Version 21 UPS configurations 1 Various settin...

Страница 14: ...32 communication RS232 Control Set RS232 communication enable or disable Enable Disable Enable 23 Manual test of the UPS Manual UPS or Manual Battery tests can be conducted from the UPS configuration...

Страница 15: ...er second High internal DC bus Voltage Turn off protected loads Turn off UPS and call your local dealer Site wiring Fault 1 Beep per second Voltage detected Between Neutral and Ground UPS mains connec...

Страница 16: ...144 VAC Frequency 50 60 Hz Auto selection Frequency window from mains 45 65 Hz Synchronization window 3Hz Input current 700 VA 5 8A 1000 VA 8 2A 1500 VA 12 4A 2000 VA 16 5A 3000 VA 24 7A Input Power...

Страница 17: ...attery mode 700 1000 VA 50 db normal and battery mode 1500 3000 VA 29 STANDARDS Safety EN50091 1 1 Emissions EN50091 2 Immunity EN50091 2 B 700 1500VA A 2K 3KVA HV Model OUTPUT POWER 700VA 490 W 1000V...

Страница 18: ...o 90 3 hours to 90 3 hours to 90 Dimensions W x D x H mm 152 x 420 x 238 152 x 420 x 238 152 x 420 x 238 225 x 425 x 360 225 x 425 x 360 Weight kg 13 5 16 2 17 31 6 33 31 19 Rack mount Model 2U OUTPUT...

Страница 19: ...20 x 238 152 x 420 x 238 225 x 425 x 360 225 x 425 x 360 Dimensions W x D x H mm RM2U 428 x 425 x 84 428 x 425 x 84 428 x 425 x 84 428 x 610 x 84 428 x 610 x 84 Tower 21 21 21 42 42 Weight Kg RM2U 22...