background image

1

/

2

 in.

(178 mm)

1

/

8

 in.

(54 mm)

Eaton

1000 Eaton Boulevard

Cleveland, OH 44122

United States

Eaton.com

Eaton’s Cooper Power Systems 

Division

2300 Badger Drive

Waukesha, WI  53188

United States

Eaton.com/cooperpowerseries

© 2015 Eaton

All Rights Reserved

Printed in USA

Publication No. MN650010EN, Rev. 0

Supersedes S500411Rev. 1

Eaton, Cooper Power, and Kearney are 

valuable trademarks of Eaton in the 

U.S. and other countries. You are not 

permitted to use the trademarks without 

the prior written consent of Eaton.

Burndy

®

 is a registered trademark of FCI.

Thomas & Betts

®

 is a registered 

trademark of Thomas and Betts.

ACA Conductor Accessories is a division 

of AFL Telecommunications LLC.

Anderson

®

 is a registered trademark of 

Hubbell Power Systems.

For Eaton's Cooper Power series “LE” 

elbow product information  

call 1-877-277-4636 or visit:  

www.eaton.com/cooperpowerseries.

!

SAFETY

FOR LIFE

Содержание 200 A 25 kV class

Страница 1: ...200 A 35 kV class LE series elbow installation instructions COOPER POWER SERIES Loadbreak Apparatus Connectors MN650010EN Effective May 2015 Supersedes S500 41 1 March 2011...

Страница 2: ...NY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no...

Страница 3: ...dling and Storage 1 Quality Standards 1 INSTALLATION INSTRUCTIONS Installation Instructions 2 Preparation of Concentric Neutral Cable 3 Elbow and Loadbreak Probe Installation 4 OPERATING PROCEDURES Lo...

Страница 4: ...afety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around high and low volt...

Страница 5: ...IONAL LOCKING RING THREE PHASE PROBE INSULATED CUFF ARC FOLLOWER PULLING EYE TEST POINT CAP DRAIN WIRE TAB LOADBREAK BAND PEROXIDE CURED SEMI CONDUCTING SHIELD INSULATION ENCAPSULATED CONDUCTIVE INSER...

Страница 6: ...Cable Cutters Clampstick Personal Protection Equipment For detailed instructions please see pages 3 4 Table 1 Crimp Chart Connector Size AWG or kcmil Catalog Number Nominal Barrel Diameter Burndy Kear...

Страница 7: ...the compression connector prior to crimping to ensure proper thread engagement Place the coppertop bimetal connector on the conductor Make sure the threaded hole in connector faces the apparatus bush...

Страница 8: ...elbow Step 7 By hand thread loadbreak probe into threaded eye of coppertop connector When tight use the provided installation tool to properly torque the loadbreak probe Proper torque is applied when...

Страница 9: ...vices to system ground per appropriate Installation Instructions All associated apparatus must also be grounded Secure elbow eye firmly onto clampstick and lock Twist clampstick clockwise until the el...

Страница 10: ...This page intentionally left blank 6 200 A 35 KV CLASS LE SERIES ELBOW INSTALLATION INSTRUCTIONS MN650010EN May 2015...

Страница 11: ...This page intentionally left blank 7 200 A 35 KV CLASS LE SERIES ELBOW INSTALLATION INSTRUCTIONS MN650010EN May 2015...

Страница 12: ...wer and Kearney are valuable trademarks of Eaton in the U S and other countries You are not permitted to use the trademarks without the prior written consent of Eaton Burndy is a registered trademark...