APP3Y2062T-EC20T
Operation and Care
All units are shipped with break-In Oil. Oil should be changed within the first 50 hours or 30 days,
whichever comes first. Use only Airbase Industries Piston Air Compressor oil.
WARNING
- under
NO
circumstance should you use AUTOMOTIVE oil, in your air compressor, as this can cause damage to your
compressor and void your warranty.
•
Check the oil level before starting.
•
Turn compressor over a few revolutions by hand to make sure that everything is free.
•
Check the belt tension.
•
Remove tools, rags, and any other objects from the vicinity of the compressor.
•
Never put hands on the belt of idle units, unless the motor is switched off and locked out.
•
Note the direction of the arrow on the flywheel and be sure that the direction of
rotation is correct when the machine is started. Correct direction is counter-clockwise when
standing facing the flywheel. Air should be drawn through the intercooler onto the cylinders for
maximum cooling.
Starting
Service
• Oil should be changed every 90 days. Oil level should be at
halfway level in sight lass.
• If oil is milky,
it should be changed
• Inspect air filters weekly and change as needed.
Tank feet should be place on vibration isolator pads available through your dealer. Anchor bolts should be
gently snug, but not tight, to allow for vibration. Remember, the bolt is only a guide to hold the compressor
in place. Do not over tighten the legs of the tank against the pads…it will damage your tank.
Caution:
Do
not set tank on dirt. Over time, the tank will tilt causing the pump to fail from in adequate lubrication.
Tank