Polar Air Electric Operated, Piston Compressors
17
Drain daily.
If unit is equipped with electronic auto drain:
1.
Check daily to ensure proper operation.
2. Clean filter daily. Refer to figure 13.
4. Do not splash lubricating oil on belts or pulleys when adjusting or replacing belts.
All units are shipped with break-in oil. Change oil within first 50 hours or 30 days of operation, whichever comes first.
DO NOT use automotive type oil.
Change oil every 90 days or if oil becomes milky.
Check proper operation of safety valve before each use. Refer to figure 12. If valve does not open manually,
replace
immediately.
Discharge pressure is generally set at 175 PSI (12.1 bar).
DO NOT
attempt to open valve while
machine is under pressure.
NOTICE
Use only Airbase Industries Oil (PN: APOL03000G1). Use of any other
product will cause product damage and void the warranty.
NEVER attempt to regulate or tamper with safety valve. Valve is sealed
and certified by ASME code and is designed to relieve system pressure
when necessary.
DANGER
Safety Valve
Tank
Changing Oil