background image

7

6

1. BMI Readout
2. Body Fat % Reading
3. Body Water % Reading
4. Muscle Mass % Reading
5. Bone Mass % Reading

6. Cal-Pal™ Daily Calorie / Basal Metabolic Rate (kcal)

7. Athlete Mode Icon
8. Male Icon
9. Female Icon

10. Height Displayed in Feet/Inches 

11. Weight Readout in Kilograms (kg)
12. Weight Readout in Pounds (lb)
13. Weight Readout in Stone (st)
14. POWER Button
15. 

s

 Forward Button

16. 

t

 Back Button

17. SET Button

LCD READOUT & BUTTON DESCRIPTION

POWER

• Turn the scale on and off

SET

• Confirmation button for selection

s

 or 

t

• Changes value of height, age and activity level, toggle between Male / Male athlete and 

Female / Female athlete in Body Fat function

• Select memory P1 - P8 in Memory mode & Recall mode
• Recall settings of memory locations

FUNCTION KEYS

BACK VIEW

Battery 

Compartment

Battery Installation and First Time Setup 

1. 

This scale operates on 3 'AAA' batteries. Batteries are included and located in the 

underside of the cardboard packing insert. Remove any plastic wrap from the 
batteries before installation. Remove any screws and open the battery cover on the 
back of the scale unit. Place the batteries into the battery compartment according 
to the “

+

” and “

-

” polarity symbols at the bottom of the compartment. Replace the 

battery compartment cover and screw(s).

 

Always replace all batteries at the same time: do not combine old and new 

batteries. Do not mix Alkaline, Carbon-Zinc (standard) or Nickel-Cadmium 

(rechargeable) batteries.

  Remove the batteries if the scale will not be used for a long period of time.

OPERATION

TIPS

Replace batteries when 

"

Lo

" is displayed.

Direction of the 3 AAA batteries 

2.

 Set units of measurements.  Your scale is set at the factory to weigh in pounds (lb). 

Press the “kg lb st” button on the bottom of the scale to switch to kilogram (kg) or 
stone (st) units of measurement. (1 stone = 14 pounds.)

3.

 Some models have a static cling label on the LCD lens to prevent scratching. Remove 

before use.

4.

 Place the scale on a hard, flat surface. Carpeted, uneven or cushioned flooring can 

negatively affect the accuracy of the reading. When in doubt, call 866-843-3905 (8 to 
5 MST).

5.

 The scale needs to be initialized and calibrated before first use and after moving your 

scale.  Place the scale on flat, hard surface. The harder the surface the more accurate 
your readings will be.  Carpeting or uneven floors may affect accuracy. Avoid soft 
flooring like Pergo™ or types of linoleum.  Firmly press on the glass platform to 

activate the backlight, but do not stand on the platform. Allow the scale to read '

0.0

and wait for it to turn off. Your scale is now calibrated and ready for use.  If you 
move the scale, or replace the batteries, repeat step #5 to calibrate again.

Содержание ESBS-55

Страница 1: ...r Bone Mass Mineral Mass BMI and Cal Pal Calorie Estimation Model ESBS 55 EatSmart Products Seattle WA 98134 Call 866 843 3905 8am to 5pm MST eatsmartproducts com Connect with EatSmart EatSmart Products EatSmartScales EatSmart Products EatSmartScales www eatsmartproducts com www eatsmartblog com ...

Страница 2: ...se fill out your purchase information for future reference Date Purchased ___________________ Place of Purchase __________________ Order ID if any __________________ If you have any questions please contact us eatsmartproducts com FCC INFORMATION Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ...

Страница 3: ...ury to you and others The icons and meanings are as follows PRECAUTION NOTICE Indicates the right conditions to use the product and to prevent damage risk and injury IMPORTANT NOTICE TO USERS Indicates important notices users should read before using the product CARE AND MAINTENANCE Indicates matters in which the possibility of damage may happen as a result of incorrect handling and improper maint...

Страница 4: ...artment cover and screw s Always replace all batteries at the same time do not combine old and new batteries Do not mix Alkaline Carbon Zinc standard or Nickel Cadmium rechargeable batteries Remove the batteries if the scale will not be used for a long period of time OPERATION TIPS Replace batteries when Lo is displayed Direction of the 3 AAA batteries 2 Set units of measurements Your scale is set...

Страница 5: ...nology but still needs to be auto calibrated after battery installation or after the scale is moved to ensure accuracy Firmly press the glass platform to activate the backlight but DO NOT stand on the platform Allow the scale to read 0 0 and wait for it to turn off Your scale is now calibrated and you can step on and weigh yourself normally Press on platform to turn on scale Weight Display IMPORTA...

Страница 6: ...k Level 4 Very Active exercise sports 6 7 days a week Level 5 Extremely Active physically demanding exercise sports or athletic training Definition of an Athlete The general consensus among researchers is that a quantitative dimension could be used in defining an athlete For example an athlete could be defined as a person who consistently trains a minimum of three times per week for two hours each...

Страница 7: ...will provide the best results Position your feet with maximum contact on the metal electrodes on the platform 1 Press the On Off button to turn the scale on A memory number P1 P8 blinks 2 Press the s or t buttons until your memory number appears Wait for the screen to show 0 0 3 When 0 0 appears on screen step on the scale with bare feet positioning your feet evenly on the scale platform with maxi...

Страница 8: ... one user profile whose last weight reading is close to the person being weighed the scale will select that user s memory number automatically The body composition estimates will then display twice before the scale turns off 5 If there is more than one user profile whose weight is close to the person being weighed within 6 6 lbs both memory numbers will appear on the screen before the scale starts...

Страница 9: ... batteries at the same time do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable ni cad ni mh etc batteries Remove the batteries if the scale is not used for a long period of time 9 Use the scale consistent with instructions provided in this manual How to Delete a User Profile In the event that two profiles conflict within 6 6 lbs of each other it is possible t...

Страница 10: ... may help to improve the electrical contact 9 If after I tried the corrective actions above I still can t solve the problem If Error messages persist after following the corrective actions above remove and reinsert the batteries after 1 minute 10 I have tried all corrective actions but still can t solve the problem Please contact the Taylor Customer Service Department at 866 843 3905 11 Why do I g...

Страница 11: ... is a component of many body fluids The amount of water in the body fluctuates with the hydration level of the body and state of health Monitoring the level of body water can be a useful tool for one s health maintenance Similar to body fat estimation the TBW function provided in this scale is based on BIA The estimated TBW may vary according to your hydration level that is how much water you have...

Страница 12: ...ur skin The slightest contraction of one of these muscles changes your facial expression Skeletal muscle generates heat as a by product of muscle activity This heat is vital for maintaining your normal body temperature Skeletal muscle represents approximately 30 of body weight of a healthy 127 8 lb woman or 40 of a 154 3 lb man International Commission on Radiological Protection 1975 23 22 7 What ...