2. INSTALLATION
2.1 Double-leaf gate
Distinguishing between leaf 1 and leaf 2 is crucial for the
device’s proper functioning
.
Leaf 1
: opens first when the gate is closed and moves second when the gate is open. Ends its closing cycle after
leaf 2.
Leaf 2
: opens second when the gate is closed and moves first when the gate is open. Ends its closing cycle before
leaf 1.
2.2 Actuator installation dimensions
Check that the distance
“
C
”
on the supporting structure of the gate does not exceed the value in the table
below.
If this distance is greater than the value in the table, it is necessary to take appropriate measures (making an
incision in the post/wall) until the distance is
greater or equal to the “C”
value.
This is necessary to prevent the linear gear motor from hitting the edge of the wall/post during closing.
The incision must be made exactly where the actuator is
installed and must be sufficiently large to allow the
complete opening cycle.
Opening
A max
B max
C max
D*
90°
160
140
90
650
110°
160
100
50
650
( *D Maximum distance)
30
Содержание 210
Страница 1: ......
Страница 13: ...3 INSTRUKCJA MONTAŻU JEDNOSTKI STEROWNICZEJ 12 ...
Страница 15: ...3 3 Połączenie elektryczne 14 ...
Страница 39: ...3 CONTROL UNIT INSTALLATION INSTRUCTIONS 38 ...
Страница 41: ...3 3 Electrical connections 40 ...
Страница 65: ...3 MONTAGEANLEITUNG FÜR DIE STEUERUNG 64 ...
Страница 67: ...3 3 Elektrische Verbindung 66 ...
Страница 91: ...3 NÁVOD NA MONTÁŽ OVLÁDACÍ JEDNOTKY 90 ...
Страница 93: ...3 3 Elektrické připojení 92 ...
Страница 117: ...3 MONTÁŽ RIADIACEJ JEDNOTKY 116 ...
Страница 119: ...3 3 Elektrické zapojenie 118 ...
Страница 143: ...3 VEZÉRLŐ EGYSÉG SZERELÉSI UTASÍTÁSA 142 ...
Страница 145: ...3 3 Elektromos bekötés 144 ...