Pow’r Up Option
Page 27
4A . Place metal washer onto the stud of the
caster.
4B . Place the caster onto the unit as shown
5A . Place the black cupped washer onto the
caster stud.
5B . Place the second metal washer into the black
washer on the caster stud.
6 . Place the lock nut onto the caster stud and
tighten securely using provided wrench.
Assembly
Page 4
Guidance and Manufacturer’s Declaration - Electromagnetic Immunity
The EasyStand Bantam Medium is intended for use in the electromagnetic environment specified below. The customer
or the user of the EasyStand Bantam Medium should assure that it is used in such an environment.
Immunity Test
Conducted RF
IEC 61000-4-6
3 Vrms
150 kHz to 80
MHz
3 Vrms
Portable and mobile RF communications equipment
should be used no closer to any part of the
EasyStand Bantam Medium, including cables, than
the recommended separation distance calculated
from the equation applicable to the frequency of the
transmitter.
Recommended separation distance
d = 1.2
√
P
d = 1.2
√
P
80 MHz to 800 MHz
d = 2.3
√
P
800 MHz to 2.5 GHz
Where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters, as deter-
mined by an electromagnetic site survey
a
, should
be less than the compliance level in each frequency
range.
b
Interference may occur in the vicinity of equipment
marked with the following symbol:
IEC 60601
Test Level
Electromagnetic Environment - Guidance
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
Compliance
Level
Radiated RF
IEC 61000-4-3
3 V/m
80 MHz to 2.5
GHz
3 V/m
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the EasyStand Bantam Medium is used exceeds the
applicable RF compliance level above, the EasyStand Bantam Medium should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the
EasyStand Bantam Medium.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
4A
4B
5A
5B