EasyIO FD-20i User Reference v1.2

 

 

Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can 
be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 
• Reorient or relocate the receiving antenna. 
• Increase the separation between the equipment and receiver. 
• Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected. 
• Consult the dealer or an experienced radio/TV technician for help. 

Caution:  Any  changes  or  modifications  not  expressly  approved  by  the  party  responsible  for  compliance 
could void the user's authority to operate this equipment. 

FCC Caution

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 

FCC Radiation Exposure Statement 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. 
This equipment should be installed and operated with minimum distance 20cm between the radiator & 
your body. 

RF  Exposure:  A  distance  of  20  cm  shall  be  maintained  between  the  antenna  and  users,  and  the 
transmitter module may not be co-located with any other transmitter or antenna. 

 

 

 

Содержание FD-20i Series

Страница 1: ...EasyIO FD 20i User Reference v1 2 EasyIO FD 20i Series User Reference...

Страница 2: ...EasyIO FD 20i User Reference v1 2 Document Change Log 1st June 2019 Document created 18th June 2019 Update power supply details 18th March 2020 Updated the temp table selection...

Страница 3: ...IO logo are registered trademarks of EasyIO Holdings Pte Ltd CPT Tool is by Online Tools Inc BACnet and ASHRAE are registered trademarks of American Society of Heating Refrigerating and Air Conditioni...

Страница 4: ...ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer o...

Страница 5: ...r Reference v1 2 Contents Introduction 6 Hardware Configurations 7 Power supply Connection 7 RS485 Connection 8 Universal Input Connection 10 Digital Input Connection 10 Buttons and Indications 12 Tec...

Страница 6: ...IO FD 20i Series controller comes with built in bootloader program Built in bootloader program will enable user to upgrade firmware without sending back to factory EasyIO FD20 do not have an Ethernet...

Страница 7: ...se individual power supply for each controller If a single power supply is used make sure controller power supplies are connected with the same polarity Electrical Characteristic Power Supply 24V AC 5...

Страница 8: ...RS485 device make sure all devices are having the same ground connection Make sure you are connecting the same wire for the same terminal position all H terminals connected to the same wire Daisy Chai...

Страница 9: ...The white the spot white square represent the DIP switch toggle button EasyIO FC 20 enlarged DIP switch Setting DIP switch number Functions Remarks 1 Protocol Setting On Bacnet MSTP Off Modus RTU 2 S...

Страница 10: ...0K with Shunt Temperature table selection Temperature table selection is via BACnet objects or Modbus register By default each UI channel temperature table is set to table 1 Table Number Temperature T...

Страница 11: ...nput Terminal Digital Imput Block Channel DI 1 DI 1 DI 2 DI 2 DI 3 DI 3 DI 4 DI 4 DI 5 DI 5 DI 6 DI 6 DI 7 DI 7 DI 8 DI 8 DI 9 DI 9 DI 10 DI 10 UI1 DI 11 UI2 DI 12 UI3 DI 13 UI4 DI 14 UI5 DI 15 UI6 DI...

Страница 12: ...d to indicate the presence of 24VAC power source and internal power 2 ERR ERR is to indicate whenever there is communication errors 3 STS STS is used to indicate the heartbeat of the Microcontroller T...

Отзывы: