EasyIO FD-20i User Reference v1.2

 

 

Disclaimer 
 

Confidentiality Notice 

The information contained in this document is confidential information of EasyIO Holdings Pte Ltd. Such 
information and the software described herein, is furnished under a license agreement and may be used 
only in accordance with that agreement. 
The information contained in this document is provided solely for use by EasyIO Holdings Pte Ltd 
employees, licensees, and system owners; and, except as permitted under the below copyright notice, is 
not to be released to, or reproduced for, anyone else. 
While every effort has been made to assure the accuracy of this document, EasyIO Holdings Pte Ltd is not 
responsible for damages of any kind, including without limitation consequential damages, arising from 
the application of the information contained herein. Information and specifications published here are 
current as of the date of this publication and are subject to change without notice. The latest product 
specifications can be found by contacting our corporate headquarters  or support channel.  
 
Trademark Notice 
 
EasyIO logo are registered trademarks of EasyIO Holdings Pte Ltd. 
 
CPT Tool is by Online Tools Inc. 
 
BACnet and ASHRAE are registered trademarks of American Society of Heating, Refrigerating and Air- 
Conditioning Engineers. All other product names and services, mentioned in this publication, that are 
known to be trademarks, registered trademarks, or service marks are the property of their respective 
owners. 
 
Copyright and Patent Notice 
This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced 
to any electronic medium or machine-readable form without prior written consent from EasyIO Holdings 
Pte Ltd 
 
Copyright © 2019 EasyIO Holdings Pte Ltd. All rights reserved 
 

Disclaimer 

The material in this manual is for information purposes only. The contents and the product it 
describes are subject to change without notice. EasyIO Holdings Pte Ltd makes no 
representations or warranties with respect to this manual. In no event shall EasyIO Holdings Pte Ltd be 
liable for any damages, direct or incidental, arising out of or related to the use of this manual. 
 
EasyIO Holdings Pte Ltd 
101, Cecil Street #09-07 
Tong Eng Building 
Singapore 069533 
  
Worldwide and Asia Pacific Support 

[email protected]

  

Americas Support 

 

 

[email protected]

  

Europe Support   

 

 

[email protected]

  

 

 

Содержание FD-20i Series

Страница 1: ...EasyIO FD 20i User Reference v1 2 EasyIO FD 20i Series User Reference...

Страница 2: ...EasyIO FD 20i User Reference v1 2 Document Change Log 1st June 2019 Document created 18th June 2019 Update power supply details 18th March 2020 Updated the temp table selection...

Страница 3: ...IO logo are registered trademarks of EasyIO Holdings Pte Ltd CPT Tool is by Online Tools Inc BACnet and ASHRAE are registered trademarks of American Society of Heating Refrigerating and Air Conditioni...

Страница 4: ...ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer o...

Страница 5: ...r Reference v1 2 Contents Introduction 6 Hardware Configurations 7 Power supply Connection 7 RS485 Connection 8 Universal Input Connection 10 Digital Input Connection 10 Buttons and Indications 12 Tec...

Страница 6: ...IO FD 20i Series controller comes with built in bootloader program Built in bootloader program will enable user to upgrade firmware without sending back to factory EasyIO FD20 do not have an Ethernet...

Страница 7: ...se individual power supply for each controller If a single power supply is used make sure controller power supplies are connected with the same polarity Electrical Characteristic Power Supply 24V AC 5...

Страница 8: ...RS485 device make sure all devices are having the same ground connection Make sure you are connecting the same wire for the same terminal position all H terminals connected to the same wire Daisy Chai...

Страница 9: ...The white the spot white square represent the DIP switch toggle button EasyIO FC 20 enlarged DIP switch Setting DIP switch number Functions Remarks 1 Protocol Setting On Bacnet MSTP Off Modus RTU 2 S...

Страница 10: ...0K with Shunt Temperature table selection Temperature table selection is via BACnet objects or Modbus register By default each UI channel temperature table is set to table 1 Table Number Temperature T...

Страница 11: ...nput Terminal Digital Imput Block Channel DI 1 DI 1 DI 2 DI 2 DI 3 DI 3 DI 4 DI 4 DI 5 DI 5 DI 6 DI 6 DI 7 DI 7 DI 8 DI 8 DI 9 DI 9 DI 10 DI 10 UI1 DI 11 UI2 DI 12 UI3 DI 13 UI4 DI 14 UI5 DI 15 UI6 DI...

Страница 12: ...d to indicate the presence of 24VAC power source and internal power 2 ERR ERR is to indicate whenever there is communication errors 3 STS STS is used to indicate the heartbeat of the Microcontroller T...