a
WARNING!
• Bus wires must not touch or cross while inserting
into power termination/end seal.
• Only power terminations/end seals specifically
approved for the vendor’s style and type of
heater cable must be used.
15. Insert bus wires into power termination.
16. Squeeze power termination ferrule open
and fill opening with silicone. (The sili-
cone will set up in about 30minutes with
a complete cure after 24 hours.)
17. Push power termination to overlap jacket.
18. Trime bus wires to exposure length
shown.
apply silicone
here
0.5" (13mm)
END SEAL
1. Remove 0.5" of overjacket exposing the
braid, then remove the 0.5" (13mm) of
exposed braid.
2. Make a 0.4" (10mm) cut at the end of the
heater cable.
3. Squeeze end seal and fill with silicone.
(The silicone will set up in about 30 min-
TSRP POWER CONNECTION KIT
Installation Instructions
4
utes with a complete cure after 24 hours.)
4. Push end seal over the heater cable.
Apply silicone here