How to operate the product

Turn on the device by spinning one or two spin dials on the side of the unit to click to 1. 

Turn on both dials on the side of the device if you want to use both channels for two separate areas. Each 
channel has its own intensity level which is adjusted via these separate dial knobs. The screen display will light 
up blue, which mesns the EHE010 device is ready to use.

You can choose between auto procedure modes or manual customized modes

i. If you prefer one of the auto-procedure modes (mixture of message types), press the button that matches 
your treatment area best such as SHOULDER or JOINT.

ii. If you prefer to customize the massage sensation by yourself, you can choose one of the manual massage 
types.

TYPES: MASSAGE, BEAT, or KNEAD labeled as MODE1, MODE2, and MODE3. This will override the 
auto-procedure mode. 

Scrolling the channel knobs will increase the intensity (strength) individually for channel A and channel B. 

Each channel has its own individually intensity knob. The intensity will have a max level of 10. Stay at a level 
that is comfortable for you. Then simply enjoy the therapy. The EHE010 device has a default speed, which is 
non- adjustable. It remains the same for any given mode and intensity chosen.

There is a default 20-minute countdown timer on the screen. You can tap the “TIMER” button to switch 
between 20, 40 and 60 minutes. The device will timeout and turn off after the session.

Quick Tips for Using Display and Adjusting Intensity

• 

Scroll Switch Knob to one to turn on corresponding channel A or B.

• 

Press one of the mode buttons to start treatment, such as SHOULDER or MODE1.

• 

Rotate the Switch Knob to adjust the intensity of either independent channel A, independent channel B, or 

both.

• 

Press TIMER to adjust the time. Choose from 20, 40, or 60 minutes, let off and press again to get to next time 

option. 20 min is the default time.

• 

Press LOCK/UNLOCK to lock/unlock the control board. This allows your setting to stay even if you 

accidentally press a button.

If you want to conclude the treatment before the timer is up, spin either dial or both dials on each side of unit 
to the “OFF” label until you hear a clicking sound.

NOTE: It is recommended to begin treatment from the lowest intensity (1) and then gradually and slowly 
adjust to a comfortable level on a scale from level 1 to 10 with 10 being the highest intensity.

NOTE: You may choose to use either the left side or the right side of the unit, or both, but the electrode pads 
must be used in pairs to work. Meaning you cannot use one electrode from each side of the unit.

How to Operate EHE010

Auto-Procedure Mode Reference Chart

BUTTON

OUTPUT RESPONSE

BACK (Automatic Mode)

COMBINATION:

BEAT output for 10s,
KNEAD output for 4s, off for 1s,
MASSAGE output for 4s, off for 2.6s, 
BEAT output for 10s, 
MASSAGE output for 4.5s,off 2.6s, 
KNEAD output for 4s, off 1s

ARM-LEG (Automatic Mode)

COMBINATION:

MASSAGE output for 4.5s, off 2.6s, 
BEAT output for 10s,
MASSAGE output for 4.5s, off 2.6s, 
BEAT output for 10s,
MASSAGE output for 4.5s, off 2.6s 

HAND-FOOT (Automatic Mode)

COMBINATION:

MASSAGE outputs for 4.5s, off 2.6s,
BEAT outputs for 10s, 
MASSAGE outputs for 4.5s, off 2.6s,
BEAT outputs for 10s, 
KNEAD output for 4s, off 1s

SHOULDER (Automatic Mode)

COMBINATION:

BEAT output for 10s

COMBINATION:

BEAT output for 10s

NECK (Automatic Mode)

JOINT (Automatic Mode)

COMBINATION:

BEAT output for 10s, 
KNEAD output for 4s, off for 1s,
BEAT output for 10s, 
MASSAGE output for 4s, off for 1s,
BEAT output for 10s

4

5

Содержание EHE010

Страница 1: ...imulator User Manual Questions or Comments Please call toll free 1 855 822 6999 M F 9 a m 5 p m CST E mail service healthcare manager com Easy Healthcare Corporation 360 Shore Dr Burr Ridge IL USA 605...

Страница 2: ...Procedure Mode Reference Chart 5 Attaching Electrode Pads to Body 6 TENS Electrode Placement Suggestions 7 Best Practices 7 FAQ 8 Specifications 9 Safety Warning 10 Electromagnetic Compatibility and F...

Страница 3: ...remaining through clear visual representations It has a smooth soft touch keypad and lock unlock feature These additional features enhance your user experience so that you can use your tens device an...

Страница 4: ...witch Knob to adjust the intensity of either independent channel A independent channel B or both Press TIMER to adjust the time Choose from 20 40 or 60 minutes let off and press again to get to next t...

Страница 5: ...to bring comfort and relief Experiment with the placement of the pads to find the position that brings the most relief to you Although place pads around the painful area and not directly on it FOREAR...

Страница 6: ...s to the proper intensity shown in the round intensity window for either side FAQ Why am I not experiencing any results While you might feel refreshed after your first treatment it takes time for long...

Страница 7: ...est may cause rhythm disturbances to the heart which could be lethal 2 over painful areas Please consult with your physician before using this device if you have painful areas 3 over open wounds or ra...

Страница 8: ...operation of the unit 3 Caution This unit has been thoroughly tested and inspected to assure proper performance and operation 4 Caution This machine should not be used adjacent to or stacked with oth...

Страница 9: ...be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth Voltage dips short interruptions and voltage variations on power supply input li...

Страница 10: ...device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can rad...

Страница 11: ...r replacements Do not let the sticky side of the pads touch anything including greasy fingertips Cleaning and Maintenance PROGRAM NAME Mode 1 Massage 62 5 100 240 1 500 62 5 100 240 Mode 2 Beat Mode 3...

Страница 12: ...ry the pad Is the adhesive surface of the pad damaged Replace the pad It is difficult to attach the pad to the skin Adhesive surface of pads is not sticky Pads get deteriorative Contact the vendor for...

Отзывы: