Warm Tiles electric floor
heating installation manual
Before you start installing the electric
floor heating, you should first read
through this manual completely.
Guarantee declaration
Provided the cables are installed in
accordance with the supplied
instructions, Easy Heat Europe BV
guarantees the Easy Heat Warm Tiles
heating cables for a period of ten years
against manufacturing and construction
defects. The total installation must
comply with locally applicable
standards and be carried out by a
recognized installer.
General points of attention
Easy Heat Warm Tiles is designed to
function as comfort electric floor
heating. It will usually be necessary
to have an additional heating source
in the room you want to heat. Ask
your installer for more information.
Easy Heat recommends the use of
Master Builders-PCI building
materials for levelling the floor and
laying (floor) tiles. Technically
comparable materials (for example
Eurocol, Schönex) may also be used.
Ask your building materials supplier
for more details.
Before you start installing, you
should make sure that the heating
cable is suitable for the surface to be
heated. Firstly, you have to estimate
the surface area of the room; this is
the area you want heated and does
not include, for example, the space
under the shower, under kitchen
cupboards etc. Secondly, you have to
estimate the distance between the
coils in the cable. To do this, look up
the distance in the table on page 2.
The distance can vary from 6 to 12
centimetres. The smaller the
distance (minimum 6 cm) the faster
your floor will heat up. A large
distance between the coils (larger
than 12 cm) combined with a low
floor height increases the chance of
cold and warm spots in the floor.