USER'S  MANUAL 

 

 

 

 

MODEL

 

                

 
 
 

 

 

 

 

 

 

 

 

 

Содержание VERSA CUT60

Страница 1: ...USER S MANUAL MODEL...

Страница 2: ...to avoid breathing gas Arc radiation harmful to your eyes and burn your skin Use suitable helmet and light filter wear protective garment to protect eyes and body Use suitable helmet or curtain to pro...

Страница 3: ...a arc It has the functions of arc initiation current arc stop current welding current basic value current current ascending time current descending time gas delay time continuous adjustment What s mor...

Страница 4: ...utput voltage V 104 112 120 144 Duty cycle 60 60 60 60 Efficiency 85 85 85 85 Power factor 0 93 0 93 0 93 0 93 Insulation grade F F F F Housing Protection grade IP21 IP21 IP21 IP21 Arcing Way Untouche...

Страница 5: ...e and compressed air source and use hoop and other way to tighten the joint Air source should supply suitable pressure flow and be dry If your air source does not meet the above requirements you shoul...

Страница 6: ...Make sure power voltage is inside the waved range Output cable connection 1 Make sure tube of pressed air is connected to copper connector by high pressure rubber tube firmly 2 Make sure copper screw...

Страница 7: ...osition 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put...

Страница 8: ...Press the control knob of torch electromagnetic valve is starting sound of HF arc striking can be heard and burner of torch should flow out gas Burner of arc supporting cutter should spurt fire 4 It i...

Страница 9: ...result current and air pressure must be matched well So when the current is set the pressure and flow must be adjusted suitably If the air flow is too big and cooling effect is too strong it will caus...

Страница 10: ...of environment User should make sure the working area is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to...

Страница 11: ...ow and input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value When voltage i...

Страница 12: ...d steam enter into inter machine if they enter into machine please dry inter machine then check insulation of machine 5 If welding machine will not be operated long time it must be put into packing bo...

Страница 13: ...ken or switch broken 3 Control circuit is broken Contact factory Abnormal indicator is lit Meter is normal Fan is normal 1 High pressure device is broken 2 IGBT is broken 3 Rectifier broken 4 Control...