ADDITIONAL ITEMS
#31721
Replacement Eastwood Air Filter Element
#31715
Replacement Eastwood Oil Filter
#31716
Replacement Eastwood Moisture Separator
#31718
1 Quart [0.946 liter] Eastwood Synthetic Scroll Compressor Oil
#20472
Eastwood Filter Separator Regulator System
#13600
3/4 in Professional Compressed Air Line Kit
TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTION
Compressor
runs con-
stantly without
cycling off
Air demand is greater than the capacity
of the Compressor
Reduce air demand. Do not exceed 12 SCFM @ 90 PSI.
Severe air leak at fittings, line or hose
Stop compressor use, locate leak and perform repair.
Does not run
when switch
is turned on
No Power
Check 220/240 VAC power source and connection to unit. If it is determined
after proper diagnostics that power is present up to the Pressure Switch, call
Eastwood Tech at: 1-800-345-1178.
Motor appears
to be running
excessively
hot
Air demand is greater than the capacity
of the Compressor
Reduce air demand. Do not exceed 12 SCFM @ 90 PSI.
Dirt, dust and debris buildup in motor
cooling air intake grille and/or Heat
exchanger
Use a soft brush or vacuum cleaner to remove debris from grille and or
Heat Exchanger.
© Copyright 2018 Easthill Group, Inc. 8/18 Instruction item #31700Q Rev 6
If you have any questions about the use of this product, please contact
The Eastwood Technical Assistance Service Department: 800.343.9353 >> email: [email protected]