background image

To order parts and supplies: 800.343.9353  >>  eastwood.com 

7

FIG. 10

BURN HAZARD! 

  The Scroll Pump generates heat during operation.  

Use caution when servicing to avoid burns.

 

  If any air or oil leaks are discovered, call Eastwood Tech at: 1-800-343-9353.

INJURY HAZARD! 

  Before performing any service, turn Power Switch 

to the “OFF” position (FIG 2). Shut off breaker or 
disconnect power supply. Release pressure from Tank 
(FIG 10) until Gauge indicates 0 PSI. and allow to cool 
minimum 1 hour after last use before servicing to 
avoid burns.

CAUTION! 

Open Slowly!

Open

Close

STEP 4 – CHECK RUN PROCEDURE

 

  Before re-installing the Cover and placing the  

Eastwood QST 30/60 in service for use, the  
following brief steps MUST be performed:

•  Close all outlet valves.
•  Connect Compressor to power supply. 
•  Move the Power Switch to the 

“ON”

 position 

(FIG 2)

.

•  Allow the Compressor to run until it builds full pressure and automatically shuts off (approx. 3 minutes) 
•  Move the Power Switch to the 

“OFF”

 position.

•  Listen for any air leakage and observe the Scroll case, all lines and fittings for any evidence of oil leakage.

•  If no leaks exist, replace the Cover and secure with the four Socket Head Cap Screws.
•  The Eastwood QST 30/60 Compressor is now ready for use.

COMPRESSOR LOCATION

FIG. 11

Lock

Unlock

 

  The Eastwood QST 30/60 Compressor is mounted on Casters and can vibrate or move slightly during operation.  

Always lock Casters before running.

POSITIONING

 

  The Eastwood QST 30/60 Compressor generates heat during 

operation. Sufficient space must be provided around the 
unit for cooling air circulation.

•  Locate the Air-Intake Grill no less than 1 foot [.3m] away from any wall  

or enclosure. 

•  Locate the sides and front of the Compressor no less than 1 foot [.3m]  

away from any wall or enclosure. 

•  Maintain at least 2 feet [.6m] of free space above the Cover. 
• 

DO NOT

 allow the Cover ventilation holes to be blocked or permanent  

damage could occur.

CASTER LOCKING

To Lock:

•  Note that both of the Swivel Casters are equipped with brakes. Push down on the Paddles to lock brakes

 (Fig 11)

, lift up on the paddles to release brakes.

Содержание QST-30/60

Страница 1: ...QST 30 60 SCROLL COMPRESSOR INSTRUCTIONS Item 31700...

Страница 2: ...moving parts and significantly reduced friction for greater reliability and longer life CONTENTS 1 Eastwood QST 30 60 Scroll Type Air Compressor 1 Dipstick 1 Instruction Manual SPECIFICATIONS Power Re...

Страница 3: ...s not in use DO NOT run the unit with the Cover removed Serious burns could occur from contact with hot components Never direct high pressure airstream to exposed flesh This compressor must be located...

Страница 4: ...sure Relief Valve has been pre set at the factory for the maximum safe pressure of this unit Personal injury and or property damage may result if the relief valve is tampered with Use only hose pipe a...

Страница 5: ...od Synthetic Scroll Compressor Oil to the fill port of the Oil Reservoir using a suitable funnel FIG 6 Replace Fill Plug and tighten securely Before starting and running the Eastwood QST 30 60 the fol...

Страница 6: ...ily draw several times its full load amperage It is important to consider this start up surge when specifying circuit breakers or fuses If fuses are used time delay type must be installed The power su...

Страница 7: ...Power Switch to the OFF position Listen for any air leakage and observe the Scroll case all lines and fittings for any evidence of oil leakage If no leaks exist replace the Cover and secure with the...

Страница 8: ...estart 115 PSI 7 9 bar The Pressure Gauge located on the side of the ON OFF and Pressure Switch indicates actual tank pressure Fig 13 FIG 13 Pressure Relief Gauge Open Close The Eastwood QST 30 60 Com...

Страница 9: ...ocedure to remove blow out and re install Air Filter Element OIL CHANGE ONLY Remove Cover by removing the four 6mm Socket Head Cap Screws located at the keyhole slots under the edge of the Cover Frame...

Страница 10: ...nk until Tank Pressure Gauge indicates 0 psi Disconnect Compressor from power supply With a suitable drain pan in place first remove the Drain plug with a 10mm Hex Key then slowly open the Drain Valve...

Страница 11: ...Power Switch to OFF Listen for any air leakage and observe the Scroll case all lines and fittings for any evidence of oil leakage If no leaks exist replace the Cover and secure with the four 6mm Socke...

Страница 12: ...power source and connection to unit If it is determined after proper diagnostics that power is present up to the Pressure Switch call Eastwood Tech at 1 800 345 1178 Motor appears to be running excess...

Отзывы: