PROBLEM
CAUSE
CORRECTION
Does Not Run
When Switch
is Turned On
No power to Hydraulic Pump Motor
Check 120 VAC input plug connection.
Check for tripped circuit breaker. The Pump Motor operates on a 15 Amp
Minimum circuit.
Motor Runs
Too Slow/
Develops Low
Power
Excessive voltage drop due to under-
sized and or too long of an extension
cord used
Extension cords not recommended. If necessary, use only 14 Gauge or larger
cord and limit length to 25’.
Cylinder Stops
Before Bend is
Completed
Low fluid level in Reservoir
Retract cylinder fully and check fluid level. Add a high quality, 10w hydraulic oil
as needed.
Tripped Circuit Breaker
Check for tripped circuit breaker. The Pump Motor operates on a 15 Amp
Minimum circuit.
Obstruction or binding of components
Retract cylinder and check thoroughly for any obstructions or binding of
components.
Material wall thickness too great and
has exceeded the maximum 0.120”
[3mm] @ 2” wall thickness capability of
the machine
Retract cylinder and re-evaluate material selection.