6
Eastwood Technical Assistance: 800.343.9353 >> [email protected]
CONNECTING THE PLASMA CUTTER
TO A POWER AND AIR SOURCE
The Eastwood Versa Cut 60 Plasma Cutter requires a dedicated 240 VAC, 50 AMP,
50/60HZ grounded outlet protected by a circuit breaker. The plug installed on the
plasma cutter is a NEMA 6-50P and should be used with a NEMA 6-50R receptacle.
As an alternative, by using the included Adapter Cord, the Versa Cut 60 can be used
with a 120 VAC, 20 AMP, 60HZ grounded NEMA 5-15R outlet protected by a circuit
breaker.
Use only UL approved, 3 conductor grounded Extension cords. Use Eastwood #31739
for 120V operation and Eastwood #20029 or #20285 for 240V operation.
Plasma cutting also requires a pressurized air source. The air must be clean and dry and
requires 5-7 CFM @ 60PSI. Usage of a moisture trap is strongly recommended. Air is
connected via the rear panel mounted 1/4” Female NPT input.
FIG. 1
FIG. 1
FIG. 2
FIG. 2
CONTROL PANEL AND FEATURES
FRONT PANEL (FIG 1)
a.
Pressure Control:
Pull out then turn knob to increase (+)
or decrease (-) pressure. To lock, push in.
b.
Pressure Gauge:
Adjust pressure control while air is flowing through the torch
to get 60psi
c.
Amperage Control:
(20A to 60A)
d.
Amperage Display:
Shows the set plasma cutting amperage
e.
Plasma Cutting Mode Setting:
Push button switches between TEST, 2T, and
4T modes
f.
Overload Indicator:
Illuminates AMBER when the Duty Cycle has been
exceeded, the plasma cutter is overloaded or if other abnormalities exist.
g.
Plasma Torch Air/Power Connection
h.
Pilot Arc Ignitor Connection
j.
Plasma Torch Trigger Connection
k.
Ground Clamp Connection
REAR PANEL (FIG 2)
aa.
120/240 VAC Power Cord
bb.
Input Air Connection
cc.
ON/OFF Switch
dd.
Data Chart
a
a
bb
cc
dd
ee
ff
aa
aa
bb
bb
cc
cc
dd
dd
g h j k
g h j k